Unit UT586+ 10–1000 mA CAT III 600V Digital RCD Tester
- Brand: Unit
- SKU: UT586+
- MPN: UT586+
- Price: 17450.40 TRY + VAT · incl. VAT 20940.48 TRY
- Availability: Made to order
- Electrical Installation Testers
- Selection guide: Electrical and Electronic Testers Selection Guide: Technical Criteria and Engineering Practice
Unit UT586+ is a digital RCD tester by UNI-T designed to verify the function of single-phase and three-phase residual current devices (RCDs); it measures the fault trip time and the trip current. With the ×½, ×1, ×2 and ×5 multipliers, rated currents of 10, 20, 30, 100, 200, 300, 500 and 1000 mA are tested (the available currents depend on the multiplier); the trip time accuracy is ±0.6% rdg ±4 dgt. The test can be started on the positive (0°) or negative (180°) half-cycle, and the AUTO RAMP test measures the trip current and time together. The working voltage is 100–440 V, and the L-PE voltage is displayed in the 30–480 V range at ±3% rdg ±3 dgt. It provides a measurement lock, a connection check, over-temperature detection, a backlight and automatic power off after 5 minutes, and runs on 8 AA batteries. Its safety category is CAT III 600 V, and the standards are IEC 61010-031 and IEC 61557-1 and -6. The tester is used for RCD checks in residential, educational, power, manufacturing, metallurgical and chemical sectors.
| AC Voltage Measurement | 30–480 V (çözünürlük 1 V), 45–65 Hz · ±3% rdg ±3 dgt (L-PE girişi) |
|---|---|
| Backlight | Var (açılıp kapatılabilir) |
| Gram | 725 g |
| Overtemperature Detection | Var (iç parçalar aşırı ısınırsa RCD testi devre dışı kalır) |
| Connection Check | Bağlantı yoksa, besleme anormalse veya enerji akmıyorsa LCD'de 'L-PE' yanıp söner |
| Low Battery Indication | Available |
| Power Source | 8 × 1.5 V AA pil |
| Auto Power Off | Var (5 min işlem yapılmazsa) |
| Measurement Lock | Var (güç bağlı değilken 0°/180° tuşuna basılı tutulur; test kabloları doğru bağlanınca test otomatik çalışır) |
| Product Dimensions | 161 mm × 117 mm × 68 mm |
| Automatic Ramp | 10 / 20 / 30 / 100 / 300 / 500 / 1000 mA · 300 ms (0°/180°) · akım doğruluğu -10%~+10%; tetikleme akımı ve süresi birlikte ölçülür |
| Manual Ramp Test | 10 / 20 / 30 / 100 / 300 / 500 / 1000 mA · 300 ms (0°/180°) · akım doğruluğu -10%~+10% |
| Operating Voltage | 100–440 V, 50/60 Hz · -15%~+10% (450 V üzerinde alarm verir ve RCD testi durur) |
| Frequency Measurement | L-PE giriş frekansı gösterilir (VOLT/FREQ tuşuyla gerilim/frekans seçilir) |
| Phase Angle Selection | 0° / 180° |
| Limit Exceeded Indication | Var (tetikleme süresi azami test süresini aşıp tetiklediğinde) |
| Operating Temperature | 0–40 °C |
| Storage Temperature | -20–70 °C |
| Pollution Degree | 2 |
| Safety Category | CAT III 600 V |
| Standards | IEC 61010-031; IEC 61557-1; IEC 61557-6 |
| Certifications | CE, RoHS |
| Color | Kırmızı ve gri |
| Standard Accessories | Kullanım kılavuzu, test kablosu seti (kırmızı/yeşil), 2 adet timsah kıskaç (kırmızı/yeşil), 2 adet test probu (kırmızı/yeşil), 8 adet 1.5 V AA pil, AB fişli test kablosu |
| RCD Test Current | ×½: 10 / 20 / 30 / 100 / 300 / 500 / 1000 mA · 0–2000 ms (0°/180°) · akım doğruluğu -10%~0%; ×1: 10 / 20 / 30 / 100 / 300 mA · 0–2000 ms, 500 / 1000 mA · 0–200 ms (0°/180°) · akım doğruluğu 0%~+10%; ×2: 10 / 20 / 30 / 100 / 200 / 300 / 500 mA · 0–200 ms (0°/180°) · akım doğruluğu 0%~+10%; ×5: 10 / 20 / 30 / 100 / 200 mA · 0–200 ms (0°/180°) · akım doğruluğu 0%~+10% |
| Accuracy | Tetikleme süresi: ±0.6% rdg ±4 dgt |
| Tested Connectors | Tek faz priz, tek faz 2 telli, 3 faz 3 telli ve 3 faz 4 telli RCD testi |
| Dual Display | Var (mA + ms) |