Motor Capacitors Selection Guide

A run capacitor stays in the circuit as long as the motor runs, while a start capacitor drops out once the motor has started; selection rests on this difference.

This guide covers what to look at when choosing products in the Motor Capacitors category.

The difference between a run capacitor and a start capacitor

The two types do different jobs in the same motor, and their construction is also different. IEC 60252-1 defines a run (operating) capacitor as a capacitor that, together with the motor's auxiliary winding, helps with starting, improves torque during operation and mostly stays in the circuit as long as the motor runs. A start capacitor, on the other hand, supplies a leading-phase current to the auxiliary winding and is taken out of the circuit after the motor has started; the requirements for this type are given in IEC 60252-2.

For this reason, one is not fitted in place of the other. In motors that need high starting torque, the two types can be present together; in this case the start capacitor works in parallel with the run capacitor during starting.

How to read the label

Failure signs and replacement

The capacitance of a run capacitor drops over the years; the motor struggles to start or cannot reach full power. Swelling or bulging may be visible on the housing of a faulty capacitor, but the absence of visible damage does not show that the capacitor is sound. Capacitance is read with a measuring instrument that can measure capacitance and compared with the label value.

If the switch in the start circuit stays closed, the start capacitor remains in the circuit continuously; in such a fault, replacing only the capacitor is not enough, and the centrifugal switch or start relay must also be checked. A capacitor can hold a charge even after the power is cut; measurement and replacement should be done according to the manufacturer's instructions, by people competent in this work.

Relationship to power capacitors and lighting capacitors

A motor capacitor is rated in µF, while the Power Capacitors in a power factor correction panel are rated in kVAr, and they are subject to separate standards: IEC 60252-1 excludes low-voltage shunt power capacitors from its scope and refers to IEC 60831-1. The product to look for to compensate the reactive power of a single-phase load is in the Single-Phase Power Capacitors group.

Some Hawcon run models are listed under the name "motor and lighting capacitor". Fluorescent and discharge lamp capacitors are also outside the scope of IEC 60252-1 and are left to IEC 61048; before using one in a luminaire circuit, verify the area of use in the product data.

Brands in this category

Order notes

Capacitors are sold by the piece. Capacitance is written in product names as "40 uF" for Hawcon and "40uf" for Tense; try both spellings in the site search. For Tense models, verify the rated voltage and housing dimensions before ordering. For a product listed as made to order, the lead time is confirmed before ordering.

Comparison and selection table

Selection CriterionPermanent Split (Motor Run) CapacitorIntermittent (Motor Start) CapacitorReplacement & Sizing Rules
Duty CycleRemains continuously in circuit with auxiliary windingEngaged only for 1–3 seconds during starting, then switched outNever substitute a start capacitor for a continuous run capacitor
Capacitance & Voltage1.5 µF – 100 µF, 400 V / 450 V AC (self-healing MKP film)50 µF – 400+ µF, 250 V / 330 V AC (electrolytic construction)Match the nameplate capacitance (µF) within ±5%
Terminals & MountingFlying wire leads or dual 6.3 mm Faston tabs, M8 base studBakelite/plastic cylinder paired with centrifugal switch/relayVerify cylinder diameter fits inside motor terminal box
Typical ApplicationPumps, fans, blowers, burners, HVAC compressorsLoaded air compressors, refrigeration & high-torque startsA 450 V AC capacitor can safely replace a 400 V AC unit

Frequently asked questions

Can a start capacitor be fitted in place of a run capacitor?

No. A start capacitor is a non-polarized electrolytic capacitor designed only for a short starting period, and after the motor has started it is taken out of the circuit by the centrifugal switch or start relay. A run capacitor, on the other hand, stays in the circuit as long as the motor runs and is made for continuous duty. The capacitance level and rated voltage of the two types are also different; choose the type with the same duty as the removed capacitor.

What happens if the µF value of a motor capacitor is chosen larger or smaller than the label?

Capacitance determines the phase difference between the main winding and auxiliary winding currents. When the value is off, the magnetic field around the rotor becomes unbalanced; the motor turns unevenly, runs noisily, loses performance, draws more energy and heats up. For this reason, the idea that a higher value will start the motor more strongly is not correct. Take the µF value on the motor label or on the removed capacitor exactly.

Can a 450 V capacitor be used in place of one marked 400 V?

A capacitor whose rated voltage is the same as or higher than the removed one can be used; one with a lower voltage is not used. IEC 60252-1 states that operating above the rated voltage shortens capacitor life. The capacitance value, however, must stay the same. Because the housing of a higher-voltage model may be larger, check from the diameter and length whether it fits the seat on the motor.

How many µF capacitor is fitted to a water pump or hydrophore motor?

There is no single answer by motor power; the value depends on the motor's winding design, and two motors of the same power may need different capacitors. The correct value is written on the motor label or on the removed capacitor. If the label is unreadable, consult the data of the pump or motor manufacturer. After finding the value, also match the duty (run or start), the rated voltage and the housing dimensions.

What does a double value such as 124-149 µF on a start capacitor mean?

Because start capacitors are electrolytic in construction, their capacitance is labeled with a range instead of a single value; 124-149 µF shows that the capacitance of the capacitor lies between these two limits. When choosing a new one, look for the same range as on the removed capacitor. The voltage value must also be checked separately; the Hawcon start models in this category are labeled 220-250 V.