SIMH Fire-Resistant Cables Selection Guide: Technical Criteria & Application Standards
SIMH Fire-Resistant Cables selection guide: technical parameters, mounting and compliance standards, and Birtaş Kablo comparison.
The SIMH FE180 cable is a multicore cable that is both heat-resistant and fire-resistant, with fine-stranded copper cores with silicone insulation bundled under a silicone outer sheath. It is used in fixed installations where power transmission must continue during a fire, and in the power and control connections of lighting and ventilation systems, machines and equipment operating in hot environments. In this category, the Birtaş SIMH-FR FE180 series is listed by the meter with 2, 3 and 4 cores in cross-sections such as 0.75 mm², 1 mm², 1.5 mm² and 2.5 mm². Choose the number of cores according to the conductor needs of the circuit, the cross-section according to load current and line length, and the fire-resistance class and duration according to the project specification. Only the FE180 class appears in the product names; if the project also requires a PH class, it should be verified from the manufacturer's data. Standard SIMH and SIHF silicone cables without the FE180 designation are heat-resistant but not fire-resistant, and they are not a substitute for this cable. The SIMH Fire-Resistant Cables category on Welibaba includes 12 active models from leading manufacturers such as Birtaş Kablo.
Key Technical Parameters for Selecting SIMH Fire-Resistant Cables
To specify the right SIMH Fire-Resistant Cables model for your panel or installation, verify the following parameters against your engineering schedule:
| Parameter | Typical Catalog Values | Verification Note |
|---|---|---|
| Rated Voltage | Uo/U: 300/500 V & 450/750 V | Verify against project schedule and load calculation |
| Separator Tape | Polyester bant veya beyaz sentetik bant veya cam elyaf bant | Verify against project schedule and load calculation |
| Copper Weight | 13 kg/km, 18 kg/km, 20 kg/km, 26 kg/km | Verify against project schedule and load calculation |
| Flame Retardance / Fire Performance | Alev geciktirici: EN 60332-1-2 & IEC 60332-1-2; Devre bütünlüğü (FE180): IEC 60331-21; Halojensizlik: EN 60754-1/-2 & IEC 60754-1/-2 | Verify against project schedule and load calculation |
Installation, Compatibility, and Commissioning Checklist
- Electrical & Mechanical Matching: Confirm that rated voltage, current capacity, and mounting dimensions align with the upstream and downstream components in Fire-Resistant Cables.
- Environmental & Enclosure Rating: Check IP protection class, housing material, and terminal capacity for dusty, humid, or high-vibration industrial environments.
- Related Product Groups: If your application calls for a different form factor or rating, compare sibling categories such as LIHH Fire-Resistant Cables, LIHCH Fire-Resistant Cables, LIH(St)H Fire-Resistant Cables.
Frequently Asked Questions
What is the first parameter to check when selecting SIMH Fire-Resistant Cables?
Start by confirming the circuit's rated electrical values and physical mounting dimensions, then use the technical attribute filters on the SIMH Fire-Resistant Cables page to narrow down compatible series.
Which SIMH Fire-Resistant Cables brands are available on Welibaba?
Welibaba currently stocks 12 active models in this category from manufacturers including Birtaş Kablo, complete with verified specifications and unit pricing.
How can I compare SIMH Fire-Resistant Cables models by manufacturer part number?
You can search directly by manufacturer SKU/order code or use the category filter panel to compare equivalent models across brands side by side.