SIMH Fire-Resistant Cables
The SIMH FE180 cable is a multicore cable that is both heat-resistant and fire-resistant, with fine-stranded copper cores with silicone insulation bundled under a silicone outer sheath. It is used in fixed installations where power transmission must continue during a fire, and in the power and control connections of lighting and ventilation systems, machines and equipment operating in hot environments. In this category, the Birtaş SIMH-FR FE180 series is listed by the meter with 2, 3 and 4 cores in cross-sections such as 0.75 mm², 1 mm², 1.5 mm² and 2.5 mm². Choose the number of cores according to the conductor needs of the circuit, the cross-section according to load current and line length, and the fire-resistance class and duration according to the project specification. Only the FE180 class appears in the product names; if the project also requires a PH class, it should be verified from the manufacturer's data. Standard SIMH and SIHF silicone cables without the FE180 designation are heat-resistant but not fire-resistant, and they are not a substitute for this cable.
Products
- Birtaş SIMH-FR FE180 4x0.75 mm2 — Birtaş Kablo · SKU: 1711 06 004 001 · TRY 176.74 · Made to order
- Birtaş SIMH-FR FE180 2x1.5 mm2 — Birtaş Kablo · SKU: 1711 08 002 001 · TRY 150.28 · Made to order
- Birtaş SIMH-FR FE180 4x2.5 mm2 — Birtaş Kablo · SKU: 1711 09 004 003 · TRY 432.16 · Made to order
- Birtaş SIMH-FR FE180 4x1.5 mm2 — Birtaş Kablo · SKU: 1711 08 004 003 · TRY 264.78 · Made to order
- Birtaş SIMH-FR FE180 3x1 mm2 — Birtaş Kablo · SKU: 1711 07 003 002 · TRY 155.23 · Made to order
- Birtaş SIMH-FR FE180 4x1 mm2 — Birtaş Kablo · SKU: 1711 07 004 003 · TRY 203.20 · Made to order
- Birtaş SIMH-FR FE180 3x1.5 mm2 — Birtaş Kablo · SKU: 1711 08 003 002 · TRY 206.70 · Made to order
- Birtaş SIMH-FR FE180 2x1 mm2 — Birtaş Kablo · SKU: 1711 07 002 001 · TRY 117.40 · Made to order
- Birtaş SIMH-FR-JB FE180 3x2.5 mm2 — Birtaş Kablo · SKU: 1711 09 003 002 · TRY 334.68 · Made to order
- Birtaş SIMH-FR FE180 2x0.75 mm2 — Birtaş Kablo · SKU: 1711 06 002 001 · TRY 99.28 · Made to order
- Birtaş SIMH-FR FE180 2x2.5 mm2 — Birtaş Kablo · SKU: 1711 09 002 001 · TRY 234.38 · Made to order
- Birtaş SIMH-FR FE180 3x0.75 mm2 — Birtaş Kablo · SKU: 1711 06 003 001 · TRY 139.78 · Made to order
How to choose SIMH Fire-Resistant Cables
The SIMH FE180 cable is a multicore cable that is both heat-resistant and fire-resistant, with fine-stranded copper cores with silicone insulation bundled under a silicone outer sheath. It is used in fixed installations where power transmission must continue during a fire, and in the power and control connections of lighting and ventilation systems, machines and equipment operating in hot environments.
- Clarify the circuit duty first: power distribution, control, fire safety, Ethernet or analog signal.
- Compare conductor cross-section, core count, insulation and shielding against the installation route.
- Switch to the proper cable family early when flex duty, oil resistance, halogen-free jacket or fire integrity is required.
Frequently asked questions
What is SIMH Fire-Resistant Cables and where is it used?
The SIMH FE180 cable is a multicore cable that is both heat-resistant and fire-resistant, with fine-stranded copper cores with silicone insulation bundled under a silicone outer sheath. It is used in fixed installations where power transmission must continue during a fire, and in the power and control connections of lighting and ventilation systems, machines and equipment operating in hot environments.
What should I compare when choosing SIMH Fire-Resistant Cables?
Choose the number of cores according to the conductor needs of the circuit, the cross-section according to load current and line length, and the fire-resistance class and duration according to the project specification.
Where can I find technical details for SIMH Fire-Resistant Cables products?
Standard SIMH and SIHF silicone cables without the FE180 designation are heat-resistant but not fire-resistant, and they are not a substitute for this cable.