SVC Solutions
SVC (static VAr compensator) solutions are power factor correction equipment that balances the reactive power of each phase separately by switching single-phase shunt reactors in steplessly with an electronic driver. They are used to complement a capacitor-stepped power factor correction panel in facilities where reactive power changes quickly, is unevenly distributed across the phases or shifts toward capacitive. The system consists of three parts: an SVC-capable reactive power relay, an inductive load driver and the shunt reactors connected to the driver. Entes SR and Tense SRL drivers are listed with total ratings such as 5 kVAr, 10 kVAr, 20 kVAr and 30 kVAr, Tibcon modules with per-phase ratings such as 3x3.33 kVAr and 3x10 kVAr, and Entes 230 V single-phase reactors with values such as 1.66 kVAr, 3.33 kVAr and 10 kVAr. Match the driver's per-phase driving capacity to the power of the reactors to be connected; compare your relay's SVC support, the permitted fuse current and the recommended cable cross-section according to the manufacturer data. This category contains drivers and reactors; SVC-compatible relays are in the reactive power control relays category.
Products
- Entes ENT.SRS1.230/3.33 Single-Phase Shunt Reactor, 230V 50Hz, 3.33kVAr — Entes · SKU: M4812 · TRY 6,655.28 · In stock
- Entes SR-10E SVC Solution Inductive Load Driver, 10kVAr — Entes · SKU: M3756 · TRY 7,564.20 · In stock
- Entes SR-20E SVC Solution Inductive Load Driver, 20kVAr — Entes · SKU: M3904 · TRY 10,374.00 · In stock
- Entes SR-30E SVC Solution Inductive Load Driver, 30kVAr — Entes · SKU: M3914 · TRY 12,490.80 · In stock
- Entes ENT.SRS1.230/10 Single-Phase Shunt Reactor, 230V 50Hz, 10kVAr — Entes · SKU: M4959 · TRY 13,894.37 · In stock
- Entes ENT.SRS1.230/6.67 Single-Phase Shunt Reactor, 230V 50Hz, 6.67kVAr — Entes · SKU: M4958 · TRY 10,368.23 · In stock
- Entes ENT.SRS1.230/1.66 Single-Phase Shunt Reactor, 230V 50Hz, 1.66kVAr — Entes · SKU: M4811 · TRY 3,339.32 · In stock
- Entes SR-05E SVC Solution Inductive Load Driver, 5kVAr — Entes · SKU: M3757 · TRY 6,220.20 · In stock
- Tibcon 3x20 kVAr Inductive Load Driver Module - TBE2105 — Tibcon · SKU: TBC-YS-60 ES · TRY 18,965.32 · In stock
- Tibcon 3x3.33 kVAr Inductive Load Driver Module - TBE2101 — Tibcon · SKU: TBC-YS-10 ES · TRY 6,693.28 · In stock
- Tibcon 3x1.66 kVAr Inductive Load Driver Module - TBE2100 — Tibcon · SKU: TBC-YS-5 ES · TRY 5,577.88 · In stock
- Tibcon 3x6.67 kVAr Inductive Load Driver Module - TBE2102 — Tibcon · SKU: TBC-YS-20 ES · TRY 9,816.84 · In stock
- Tibcon 3x16.67 kVAr Inductive Load Driver Module - TBE2104 — Tibcon · SKU: TBC-YS-50 ES · TRY 16,734.08 · In stock
- Tibcon 3x10 kVAr Inductive Load Driver Module - TBE2103 — Tibcon · SKU: TBC-YS-30 ES · TRY 12,271.16 · In stock
- Tense SRL-5T SVC Inductive Load Driver, 5 kVAr — Tense · SKU: SRL-5T · TRY 5,170.00 · In stock
- Tense SRL-30T SVC Inductive Load Driver, 30 kVAr — Tense · SKU: SRL-30T · TRY 11,350.50 · In stock
- Tense SRL-10T SVC Inductive Load Driver, 10 kVAr — Tense · SKU: SRL-10T · TRY 6,711.60 · In stock
- Tense SRL-20T SVC Inductive Load Driver, 20 kVAr — Tense · SKU: SRL-20T · TRY 9,324.80 · In stock
How to choose SVC Solutions
SVC (static VAr compensator) solutions are power factor correction equipment that balances the reactive power of each phase separately by switching single-phase shunt reactors in steplessly with an electronic driver. They are used to complement a capacitor-stepped power factor correction panel in facilities where reactive power changes quickly, is unevenly distributed across the phases or shifts toward capacitive.
- Take reactive power demand and harmonic distortion levels from site measurements or project calculations.
- Compare kVAr step sizes, rated voltage and step count against the compensation panel layout.
- Select capacitor duty contactors, harmonic filter reactors and discharge resistors together with the capacitor bank.
Frequently asked questions
What is SVC Solutions and where is it used?
SVC (static VAr compensator) solutions are power factor correction equipment that balances the reactive power of each phase separately by switching single-phase shunt reactors in steplessly with an electronic driver. They are used to complement a capacitor-stepped power factor correction panel in facilities where reactive power changes quickly, is unevenly distributed across the phases or shifts toward capacitive.
What should I compare when choosing SVC Solutions?
Match the driver's per-phase driving capacity to the power of the reactors to be connected; compare your relay's SVC support, the permitted fuse current and the recommended cable cross-section according to the manufacturer data.
Which product groups are available under SVC Solutions?
The current subcategories include SVC Inductive Load Drivers, SVC Shunt Reactors. Open a subcategory to compare its products and technical details.