Unit UT210A 200A AC Mini Digital Clamp Meter

Unit UT210A 200A AC Mini Digital Clamp Meter

Unit UT210A is the AC-current-only mini digital clamp meter of the UNI-T UT210 series; it has a 2000-count display and measures average-responding values. Its ranges are 2.000 A (1 mA resolution, ±(4%+30)), 20.00 A (10 mA, ±(3%+20)) and 200.0 A (100 mA, ±(2.5%+20)), and the overload protection is 200 A. The jaw opening is 16 mm, the dimensions are 158 mm × 60 mm × 33.5 mm and the weight is 150 g including batteries. It runs on 2 AAA batteries and provides data hold, maximum hold, a backlight and automatic power off after 15 minutes. The UT210 series is designed for maintenance of mechanical and electrical equipment in confined spaces, home appliance installation and electrical work.

AC Current Measurement2.000 A · ±(4%+30); 20.00 A · ±(3%+20); 200.0 A · ±(2.5%+20)
Gram150 g (piller dahil)
Display Size39.3 mm × 26.5 mm
Display Count2000
Power Source2 × 1.5 V AAA pil (R03)
Range SelectionManuel (2 A / 20 A / 200 A)
Standard Accessories2 adet AAA pil, kullanım kılavuzu
Jaw Opening16 mm
Product Dimensions158 mm × 60 mm × 33.5 mm
Resolution1 mA (2 A); 10 mA (20 A); 100 mA (200 A)
AC Current Frequency Response50–60 Hz
True RMSNo (ortalama değerli ölçüm, sinüs dalgası etkin değerini gösterir)
Overload Protection200 A
Sampling Rate2–3 ölçüm/s
Data HoldAvailable
MIN/MAXYalnız maksimum değer tutma (MAXH)
BacklightVar (HOLD tuşuna 2 s basılı tutarak açılır/kapanır)
Auto Power OffVar (15 min)
Low Battery IndicationVar (pil gerilimi <2.5 V)
Safety CategoryCAT II 600 V / CAT III 300 V
Pollution Degree2
StandardsEN 61010-1; EN 61010-2-032; EN 61010-2-033; UL 61010-1; CSA C22.2 No. 61010-1
CertificationsCE, UKCA, cETLus
Operating Temperature0–40 °C
Storage Temperature-10–50 °C
Operating Humidity≤75% (0–30 °C); ≤50% (30–40 °C)
Operating Altitude0–2000 m
ColorKırmızı ve gri
Accuracy Environment23 °C ±5 °C; ≤75% bağıl nem (doğruluk garantisi 1 yıl)