CEE Straight Panel Sockets Selection Guide

When selecting CEE straight panel sockets, compare 16 A–125 A rating, 3/4/5 poles, flange mounting dimensions (mm), blue/red voltage coding and IP44/IP67 hinged lids.

This guide explains what to look for when choosing products in the CEE Straight Panel Sockets category for combination distribution boxes, generator canopies, UPS cabinets and machine tool panels.

Straight (90°) flange geometry and panel cutout dimensions

CEE straight panel sockets mount perpendicular (90°) to the enclosure face, offering a compact square footprint ideal for densely populated combination boxes. When replacing an existing socket or laying out a cutout, verify the outer flange dimensions (e.g. 55×55, 65×65, 75×75, 85×85 mm), 4-hole fixing centers and rear barrel diameter.

Current rating (16 A – 125 A), pole count (3P / 4P / 5P) and IP44 / IP67 lid

Select Blue 3-pole (2P+E) for 230 V single-phase outlets, Red 4-pole (3P+E) for 400 V three-phase loads without neutral, and Red 5-pole (3P+N+E) for 400 V three-phase + neutral loads. Choose spring-hinged IP44 lids for general panels or bayonet-ring IP67 lids for outdoor washdown and construction environments.

CEE straight panel socket comparison table

Selection Criterion16 A Straight Panel Socket32 A Straight Panel Socket63 A / 125 A Straight Panel Socket
Poles & Voltage3P (230 V Blue), 4P / 5P (400 V Red)3P (230 V Blue), 4P / 5P (400 V Red)4P (3P+E) or 5P (3P+N+E) 400 V Red
Ingress ProtectionIP44 hinged lid or IP67 bayonet ring lidIP44 or IP67IP67 (or IP44) heavy-duty flange
Terminal Wire Size1.5 – 4 mm² rear screw/spring terminals2.5 – 10 mm² rear terminals6 – 25 mm² (63 A) / 16 – 70 mm² (125 A)
Typical ApplicationSocket-mounted combination boxes, small gensetsIndustrial control panels, welders, site boardsStandby generators, shore power & heavy distribution

Frequently asked questions

When should I use a straight panel socket instead of an angled panel socket?

Straight panel sockets have a smaller vertical flange footprint, making them the standard choice when arranging multiple sockets side by side on combination boxes or mounting on the underside of an enclosure.

What measurements matter when replacing a damaged panel socket on a combination box?

In addition to matching the current (16 A vs 32 A) and poles (4P vs 5P), measure the square flange width/height (mm) and screw hole center-to-center spacing so it bolts directly onto the existing enclosure cutout.

How much internal clearance is needed behind a straight panel socket?

The rear terminal body protrudes 25 mm to 55 mm inside the enclosure behind the flange, so ensure there is adequate clearance before any internal DIN rail or mounting plate.