LIY(St)C2Y Signal Cables

The LIY(St)C2Y cable is an outdoor signal cable with a dual shield made of aluminum foil and copper braid over PVC-insulated cores, and a polyethylene (PE) outer sheath. It is used on long measurement and data lines that run near drives, transformers and power cables in open areas, and in places where both moisture and strong electromagnetic interference are present. In the category, Reçber Kablo's LIY(St)C2Y family is sold by the meter in cross-sections such as 2x1.5 mm², 4x0.75 mm², 7x2.5 mm² and 12x0.50 mm². Choose the number of cores according to the number of signals and the cross-section according to line length and circuit current; determine the conduit and gland according to the cable's outer diameter. The two shield layers make the cable thicker and require a wider bending radius; the project determines at which end the shields will be grounded. LIY(St)C2Y should not be confused with LI2Y(St)CY, whose core insulation is polyethylene: in this cable it is the outer sheath that is polyethylene, and the core insulation is PVC.

Products

How to choose LIY(St)C2Y Signal Cables

The LIY(St)C2Y cable is an outdoor signal cable with a dual shield made of aluminum foil and copper braid over PVC-insulated cores, and a polyethylene (PE) outer sheath. It is used on long measurement and data lines that run near drives, transformers and power cables in open areas, and in places where both moisture and strong electromagnetic interference are present.

  • Clarify the circuit duty first: power distribution, control, fire safety, Ethernet or analog signal.
  • Compare conductor cross-section, core count, insulation and shielding against the installation route.
  • Switch to the proper cable family early when flex duty, oil resistance, halogen-free jacket or fire integrity is required.

Frequently asked questions

What is LIY(St)C2Y Signal Cables and where is it used?

The LIY(St)C2Y cable is an outdoor signal cable with a dual shield made of aluminum foil and copper braid over PVC-insulated cores, and a polyethylene (PE) outer sheath. It is used on long measurement and data lines that run near drives, transformers and power cables in open areas, and in places where both moisture and strong electromagnetic interference are present.

What should I compare when choosing LIY(St)C2Y Signal Cables?

Choose the number of cores according to the number of signals and the cross-section according to line length and circuit current; determine the conduit and gland according to the cable's outer diameter.

Where can I find technical details for LIY(St)C2Y Signal Cables products?

LIY(St)C2Y should not be confused with LI2Y(St)CY, whose core insulation is polyethylene: in this cable it is the outer sheath that is polyethylene, and the core insulation is PVC.

LIY(St)C2Y Signal Cables Selection Guide: Technical Criteria and Engineering Practice