LIYC2Y Signal Cables

The LIYC2Y cable is a shielded signal cable made for outdoor use, with a copper braid shield and a polyethylene (PE) outer sheath over PVC-insulated stranded copper cores. It is used to carry measurement and data signals in places exposed to both moisture and electrical noise, such as treatment plants, pump stations, open areas and rooftop equipment. In the category, Reçber Kablo's LIYC2Y family is sold by the meter in cross-sections such as 3x1 mm², 7x2.5 mm², 8x0.75 mm² and 12x1.5 mm². Choose the number of cores according to the number of measurement and data signals and the cross-section according to line length; verify from the project whether the shield will be grounded on the field side or the panel side, and verify from the manufacturer's data whether the cable is suitable for underground installation. The continuity of the braid shield must be maintained at splices and transition points; otherwise the noise suppression provided by the shield is reduced. LIYC2Y is not an armored cable: the PE sheath protects against moisture, and on routes with a risk of impact or rodents, an armored type or additional mechanical protection is required.

Products

How to choose LIYC2Y Signal Cables

The LIYC2Y cable is a shielded signal cable made for outdoor use, with a copper braid shield and a polyethylene (PE) outer sheath over PVC-insulated stranded copper cores. It is used to carry measurement and data signals in places exposed to both moisture and electrical noise, such as treatment plants, pump stations, open areas and rooftop equipment.

  • Clarify the circuit duty first: power distribution, control, fire safety, Ethernet or analog signal.
  • Compare conductor cross-section, core count, insulation and shielding against the installation route.
  • Switch to the proper cable family early when flex duty, oil resistance, halogen-free jacket or fire integrity is required.

Frequently asked questions

What is LIYC2Y Signal Cables and where is it used?

The LIYC2Y cable is a shielded signal cable made for outdoor use, with a copper braid shield and a polyethylene (PE) outer sheath over PVC-insulated stranded copper cores. It is used to carry measurement and data signals in places exposed to both moisture and electrical noise, such as treatment plants, pump stations, open areas and rooftop equipment.

What should I compare when choosing LIYC2Y Signal Cables?

Choose the number of cores according to the number of measurement and data signals and the cross-section according to line length; verify from the project whether the shield will be grounded on the field side or the panel side, and verify from the manufacturer's data whether the cable is suitable for underground installation.

Where can I find technical details for LIYC2Y Signal Cables products?

LIYC2Y is not an armored cable: the PE sheath protects against moisture, and on routes with a risk of impact or rodents, an armored type or additional mechanical protection is required.

LIYC2Y Signal Cables Selection Guide: Technical Criteria and Engineering Practice