N2XH Cables

N2XH cable is a power cable with a rated voltage of 0.6/1 kV, with copper conductors, cross-linked polyethylene (XLPE) insulation and a halogen-free, flame-retardant outer sheath. It is installed fixed in cable trays and shafts on main supply and riser lines in buildings with high occupancy, such as hospitals, shopping malls, hotels and metro stations. In this category, configurations such as 1x16 mm², 1x240 mm², 2x2.5 mm², 5x10 mm² and 3x120+70 mm² are sold by the meter from brands such as HES Kablo, Nexans, Win Kablo and Ünal Kablo. Choose the cross-section according to load current, permissible voltage drop and installation condition, the number of cores according to the phase, neutral and protective conductor arrangement, and the reaction-to-fire class according to the project specification. Because XLPE insulation allows a conductor operating temperature of 90 °C, N2XH carries a higher current than PVC-insulated NYY cable at the same cross-section and under the same installation condition; the exact value is taken from the manufacturer's current carrying capacity table. N2XH is halogen-free but is not a fire-resistant cable: N2XH FE180 is used in circuits that must keep supplying power during a fire.

Products

How to choose N2XH Cables

N2XH cable is a power cable with a rated voltage of 0.6/1 kV, with copper conductors, cross-linked polyethylene (XLPE) insulation and a halogen-free, flame-retardant outer sheath. It is installed fixed in cable trays and shafts on main supply and riser lines in buildings with high occupancy, such as hospitals, shopping malls, hotels and metro stations.

  • Clarify the circuit duty first: power distribution, control, fire safety, Ethernet or analog signal.
  • Compare conductor cross-section, core count, insulation and shielding against the installation route.
  • Switch to the proper cable family early when flex duty, oil resistance, halogen-free jacket or fire integrity is required.

Frequently asked questions

What is N2XH Cables and where is it used?

N2XH cable is a power cable with a rated voltage of 0.6/1 kV, with copper conductors, cross-linked polyethylene (XLPE) insulation and a halogen-free, flame-retardant outer sheath. It is installed fixed in cable trays and shafts on main supply and riser lines in buildings with high occupancy, such as hospitals, shopping malls, hotels and metro stations.

What should I compare when choosing N2XH Cables?

Choose the cross-section according to load current, permissible voltage drop and installation condition, the number of cores according to the phase, neutral and protective conductor arrangement, and the reaction-to-fire class according to the project specification.

Where can I find technical details for N2XH Cables products?

N2XH is halogen-free but is not a fire-resistant cable: N2XH FE180 is used in circuits that must keep supply

N2XH Halogen-Free Power Cables Selection Guide