N2XH FE180 Cables

N2XH FE180 cable is a fire-resistant power cable with a rated voltage of 0.6/1 kV, with copper conductors, XLPE insulation and a halogen-free sheath, built to maintain insulation integrity for 180 minutes under flame. It is used on the supply lines of equipment that must keep operating during a fire, such as fire pumps, smoke extraction fans, firefighter elevators, emergency lighting and emergency announcement systems. In this category, configurations such as 1x120 mm², 3x1.5 mm², 4x6 mm², 4x70 mm² and 3x35+16 mm² are sold by the meter from Koç Kablo, Öznur Kablo, Nexans and Prysmian. Choose the core configuration according to the phase, neutral and protective conductor needs of the equipment being supplied, the cross-section according to load current, voltage drop and line length, and the fire resistance class according to the duration the project specification requires for the circuit in question. Standard N2XH does not replace FE180 cable in circuits that require power continuity during a fire; FE180 refers only to the insulation integrity of the cable, while E30 or E90 refers to the circuit integrity the cable provides together with its support system, and the project specifies which one is required.

Products

How to choose N2XH FE180 Cables

N2XH FE180 cable is a fire-resistant power cable with a rated voltage of 0.6/1 kV, with copper conductors, XLPE insulation and a halogen-free sheath, built to maintain insulation integrity for 180 minutes under flame. It is used on the supply lines of equipment that must keep operating during a fire, such as fire pumps, smoke extraction fans, firefighter elevators, emergency lighting and emergency announcement systems.

  • Clarify the circuit duty first: power distribution, control, fire safety, Ethernet or analog signal.
  • Compare conductor cross-section, core count, insulation and shielding against the installation route.
  • Switch to the proper cable family early when flex duty, oil resistance, halogen-free jacket or fire integrity is required.

Frequently asked questions

What is N2XH FE180 Cables and where is it used?

N2XH FE180 cable is a fire-resistant power cable with a rated voltage of 0.6/1 kV, with copper conductors, XLPE insulation and a halogen-free sheath, built to maintain insulation integrity for 180 minutes under flame. It is used on the supply lines of equipment that must keep operating during a fire, such as fire pumps, smoke extraction fans, firefighter elevators, emergency lighting and emergency announcement systems.

What should I compare when choosing N2XH FE180 Cables?

Choose the core configuration according to the phase, neutral and protective conductor needs of the equipment being supplied, the cross-section according to load current, voltage drop and line length, and the fire resistance class according to the duration the project specification requires for the circuit in question.

Where can I find technical details for N2XH FE180 Cables products?

Standard N2XH does not replace FE180 cable in circuits that require power continuity during a fire; FE180 refers only to the insulation integrity of the cable, while E30 or E90 refers to the circuit integrity the cable provides together with its support system, and the project specifies

N2XH FE180 (E90) Fire-Resistant Power Cables Selection Guide