NYM Antigron Cables

NYM cable, also known on the market as Antigron or NVV, is a multi-core fixed installation cable with a rated voltage of 300/500 V, with copper conductors, PVC insulation, filler and a PVC outer sheath. It is used in homes and workplaces on flush-mounted and surface-mounted lighting, socket and equipment supply lines, in dry, damp and wet locations. In this category, Antigron cables are offered and sold by the meter in core counts and cross-sections such as 2x1.5 mm², 2x2.5 mm², 3x1.5 mm², 3x2.5 mm², 3x4 mm², 5x2.5 mm² and 5x10 mm² from brands such as HES Kablo, Koç Kablo, Nexans and Prysmian. First determine the number of cores according to whether the circuit is single-phase or three-phase, then choose the cross-section according to load current, line length and whether the installation is flush-mounted or surface-mounted. In buildings with a halogen-free cable requirement, NHXMH is preferred for the same use. NYM (Antigron) does not replace NYY cable on lines buried directly in the ground; NYY in the 0.6/1 kV class is used for underground power lines.

Products

How to choose NYM Antigron Cables

NYM cable, also known on the market as Antigron or NVV, is a multi-core fixed installation cable with a rated voltage of 300/500 V, with copper conductors, PVC insulation, filler and a PVC outer sheath. It is used in homes and workplaces on flush-mounted and surface-mounted lighting, socket and equipment supply lines, in dry, damp and wet locations.

  • Clarify the circuit duty first: power distribution, control, fire safety, Ethernet or analog signal.
  • Compare conductor cross-section, core count, insulation and shielding against the installation route.
  • Switch to the proper cable family early when flex duty, oil resistance, halogen-free jacket or fire integrity is required.

Frequently asked questions

What is NYM Antigron Cables and where is it used?

NYM cable, also known on the market as Antigron or NVV, is a multi-core fixed installation cable with a rated voltage of 300/500 V, with copper conductors, PVC insulation, filler and a PVC outer sheath. It is used in homes and workplaces on flush-mounted and surface-mounted lighting, socket and equipment supply lines, in dry, damp and wet locations.

What should I compare when choosing NYM Antigron Cables?

First determine the number of cores according to whether the circuit is single-phase or three-phase, then choose the cross-section according to load current, line length and whether the installation is flush-mounted or surface-mounted.

Where can I find technical details for NYM Antigron Cables products?

NYM (Antigron) does not replace NYY cable on lines buried directly in the ground; NYY in the 0.6/1 kV class is used for underground power lines.

NYM Antigron Cables Selection Guide