Control Transformers
Products
- Siemens 4AX3002-3HA50-0B Control Transformer 230-400/24 V 50 VA — Brand: Siemens · SKU: 4AX3002-3HA50-0B · TRY 4,262.00 · In stock
- Siemens 4AX3002-3ED03-0B Control Transformer 400/230 V 250 VA — Brand: Siemens · SKU: 4AX3002-3ED03-0B · TRY 9,108.00 · In stock
- Siemens 4AX3002-3HA10-0B Control Transformer 230-400/24 V 100 VA — Brand: Siemens · SKU: 4AX3002-3HA10-0B · TRY 5,517.00 · In stock
- Siemens 4AX3002-3ED06-0B Control Transformer 400/230 V 630 VA — Brand: Siemens · SKU: 4AX3002-3ED06-0B · TRY 20,420.00 · In stock
- Siemens 4AX3002-3HA16-0B Control Transformer 230-400/24 V 160 VA — Brand: Siemens · SKU: 4AX3002-3HA16-0B · TRY 6,659.00 · Made to order
- Siemens 4AX3002-3HA06-0B Control Transformer 230-400/24 V 630 VA — Brand: Siemens · SKU: 4AX3002-3HA06-0B · TRY 19,236.00 · Made to order
- Siemens 4AX3002-3HA03-0B Control Transformer 230-400/24 V 250 VA — Brand: Siemens · SKU: 4AX3002-3HA03-0B · TRY 8,582.00 · Made to order
- Siemens 4AX3002-3ED04-0B Control Transformer 400/230 V 400 VA — Brand: Siemens · SKU: 4AX3002-3ED04-0B · TRY 14,204.00 · Made to order
- Siemens 4AX3002-3ED16-0B Control Transformer 400/230 V 160 VA — Brand: Siemens · SKU: 4AX3002-3ED16-0B · TRY 7,186.00 · Made to order
How to choose Control Transformers
The Entes series is offered in 230/24 V and 400/24 V models in steps from 25 VA to 630 VA. The weight and the A, B, C and D dimensions grow with power, so the space inside the panel and the screw hole spacing should be calculated in advance. Because the output voltage is 24 V, low-voltage elements such as coils and indicators are connected. A suitable protection element must be used on the primary side. A reserve power margin should be allowed above the load for every step used.
Frequently asked questions
What are Control Transformers and where are they used?
A control transformer is a small-power transformer that isolates the control circuits in a panel from the mains voltage and supplies them at low voltage. It is used in panels that need a 24 V output, such as for relay and contactor coils and pilot lights.
What should I compare when choosing Control Transformers?
Choose the power step according to the total VA of the loads, and check that the primary voltage is 230 or 400 V and the inrush current.
What should Control Transformers not be confused with and how do they differ from similar products?