Klemsan 600100 CT3-AC True RMS Current Transducer, 0–5 A AC Input, 85–265 V AC/DC Supply

Klemsan 600100 CT3-AC True RMS Current Transducer, 0–5 A AC Input, 85–265 V AC/DC Supply

Klemsan 600100 is the CT3-AC AC supplied, isolated true RMS current transducer with a selectable 0–1, 0–2, 0–3, 0–4 or 0–5 A AC input range; output signal: Current: 0–20 mA, 4–20 mA, ±20 mA, 20–0 mA, 20–4 mA; voltage: 0–5 V, 0–10 V, ±5 V, ±10 V, 10–0 V (selectable on the product). Technical values: Model: CT3-AC; Product type: True RMS current transducer; Input signal: 0–1 A, 0–2 A, 0–3 A, 0–4 A, 0–5 A AC (selectable on the product); Input signal frequency: 40–70 Hz; Output signal: Current: 0–20 mA, 4–20 mA, ±20 mA, 20–0 mA, 20–4 mA; voltage: 0–5 V, 0–10 V, ±5 V, ±10 V, 10–0 V (selectable on the product); Supply voltage: 85–265 V AC/DC; Power consumption: DC < 1.5 W; AC < 4 VA; Isolation: 1.5 kV rms, 3 way; Test voltage: Input to output 4 kV (1 min); Accuracy: < 0.2%; Response time: 350 ms; Max. output current: 24 mA; Max. output voltage: 12 V; Max. load: 10 kΩ (voltage output) / 600 Ω (current output); Overload capacity: Continuous 10 A (2 x class In); 20 x In (100 A) for 1 s; Operating temperature: -20…+60 °C; Storage temperature: -40…+75 °C; Relative humidity: Max. 95% (non-condensing); Degree of protection: IP20; Width: 36 mm; Weight: 87 g; Output ripple: < 80 mV; Temperature coefficient: 150 ppm/°C; Mounting position: Any. The CT3 and VT3 series is designed as a smart analog input module for the direct measurement of varying quantities in in-station control applications. There is galvanic isolation between input, output and supply. It is used to convert alternating current into an analog signal (current or voltage) suitable for PLCs, SCADA systems or indicators.

ModelCT3-AC
Product TypeGerçek RMS akım transdüseri
Input signal0–1 A, 0–2 A, 0–3 A, 0–4 A, 0–5 A AC (ürün üzerinden selectable)
Input frequency40–70 Hz
Output SignalAkım: 0–20 mA, 4–20 mA, ±20 mA, 20–0 mA, 20–4 mA; gerilim: 0–5 V, 0–10 V, ±5 V, ±10 V, 10–0 V (ürün üzerinden selectable)
Supply Voltage85–265 V AC/DC
Power ConsumptionDC < 1.5 W; AC < 4 VA
Isolation1.5 kV rms, 3 yollu
Test VoltageGiriş-çıkış arası 4 kV (1 min)
Accuracy< 0.2%
Response Time350 ms ms
Maximum Output Current24 mA A
Maximum Output Voltage12 V
Maximum Payload10 kΩ (gerilim çıkışı) / 600 Ω (akım çıkışı)
Overload CapacitySürekli 10 A (2 x Class In); 1 s için 20 x In (100 A)
Operating Temperature-20...+60 °C
Storage Temperature-40...+75 °C
Relative HumidityMax. 95% (non-condensing)
IP RatingIP20
Width36 mm
Gram87 g
Temperature Coefficient150 ppm/°C
Output Ripple< 80 mV
Mounting PositionTümü