What Is a Process Calibrator? Types and Selection Criteria

A process calibrator is a handheld test device that measures and generates 4-20 mA, voltage, resistance and temperature sensor signals to test field instruments.

Original Welibaba illustration of Process Calibrators

A process calibrator is a handheld test device that both measures and generates process signals such as 4-20 mA current loops, DC voltage, resistance and temperature sensors, and is used to test the accuracy of field devices. It is used in commissioning, periodic verification and troubleshooting of instruments such as transmitters, PLC analog input cards, indicators, recorders and valve positioners.

Types

TypeWhat it doesModel in the catalog
Temperature calibratorTests temperature transmitters, indicators and controllers by generating or measuring a temperature sensor signalUNI-T UT701
Current and voltage (loop) calibratorGenerates and measures mA signals and measures DC voltage; tests 4-20 mA loopsUNI-T UT705
Multifunction process calibratorCombines several signal types in one device; temperature- or loop-focused types existUNI-T UT714 (temperature), UT715 (loop), UT725

Compare which signals each model generates and measures in the specification list on the product page.

Source and simulation modes of the current output

Selection criteria

  1. Signal types: The calibrator must be able to generate and measure the input and output signals of the devices to be tested: mA, V or mV, Ω, thermocouple type and RTD (e.g. Pt100).
  2. Accuracy: The calibrator should be clearly more accurate than the tolerance of the device under test; common practice is at least a fourfold margin. Accuracy is given as ±(percentage of reading + digits); some models in the catalog state ±(0.02% + 2) for DC voltage and current functions.
  3. Current mode: If the loop is externally powered, SIM mode is used; if not, source mode. If you will measure a transmitter in the field without its own supply, choose a model that provides loop power.
  4. Temperature signal: Cold junction compensation in thermocouple simulation and 2-, 3- or 4-wire connection support in RTD measurement directly affect the result.
  5. Field use: Step and ramp outputs speed up valve and indicator tests. The catalog has models powered by a 9 V (6F22) battery and by a rechargeable AA battery pack.

Common mistakes

Models in the catalog

All 5 active products in the Process Calibrators category are Unit branded: UT701, UT705, UT714, UT715 and UT725. All can be ordered directly. For measurement-only work see Digital Multimeters; for thermometers and temperature meters see the Temperature and Heat Control Instruments category.

Frequently asked questions

What is the difference between a process calibrator and a multimeter?

A multimeter only measures current, voltage and resistance. A process calibrator measures these signals and also generates them at known values; transmitters and analog inputs are tested with this signal.

What is the difference between source and simulation (SIM) mode?

In source mode the calibrator generates the loop current from its own supply. In SIM mode an external supply powers the loop and the calibrator only sets the current, behaving like a two-wire transmitter.

Can a HART transmitter be adjusted with a process calibrator?

The calibrator shows the error by applying a known signal to the transmitter input and measuring its output. Changing parameters over HART requires a device that communicates via HART; this communication usually needs a 250 Ω resistor in the loop. Check the model's HART support on the product page.

How often should a process calibrator be calibrated?

The interval is set by the manufacturer's recommendation and your quality system; common practice is once a year.