Klemsan 606011 RAPIDUS 211R Single-Phase Reactive Power Control Relay, 12 Steps, RS-485, 144x144

Klemsan 606011 RAPIDUS 211R Single-Phase Reactive Power Control Relay, 12 Steps, RS-485, 144x144

Klemsan 606011 is the RAPIDUS 211R reactive power control relay with single-phase current input from one current transformer, 12 steps and a graphic LCD; it has DCM, a generator input and Modbus RTU communication. Technical values: Model: RAPIDUS 211R; Product type: Reactive power control relay; Number of steps: 12; Current input: Single-phase current input (1 current transformer); Communication type: RS-485 (Modbus RTU); Display: Graphic LCD; Harmonic measurement: Up to the 51st harmonic; THD-V and THD-I; Dynamic capacitor monitoring: DCM available; Generator input: 1 input; 95–240 V AC, 45–65 Hz; Number of relay outputs: 12 compensation NO (SPST), 2 A / 250 V AC, 500 VA; 2 alarm NO (SPST), 4 A / 250 V AC, 1000 VA; Current measurement range: 10 mA – 6 A AC; Voltage measurement range: L-N 95–410 V AC ±10%; L-L 95–410 V AC ±10%; 45–65 Hz; Supply voltage: 95–410 V AC ±10% (La-Lb), 45–65 Hz; Power consumption: < 10 VA; Current transformer ratio: 1–5000; Target power factor: 0.8 capacitive – 0.8 inductive, adjustable; Communication protocol: Modbus RTU; 2400–115200 bps; address 1–247; Operating temperature: -20…+55 °C; Storage temperature: -30…+80 °C; Relative humidity: Max. 95% (non-condensing); Degree of protection: Front IP40 / rear IP20 (IP66 with accessory); Mounting type: Panel mounting; Panel cut-out: 144x144 mm; Weight: 663 g. The relay outputs consist of 12 compensation (NO, 2 A / 250 V AC) and 2 alarm (NO, 4 A / 250 V AC) outputs; hourly, daily and monthly min/max/average records and 50 alarm records are kept. The interface languages are Turkish, English and Russian; a real-time clock and battery are fitted. A silicone protection cover with code 250 001 is the accessory for IP66 at the front. It is used in compensation panels to monitor reactive power with single-phase current measurement and to switch capacitor and shunt reactor steps in and out.

ModelRAPIDUS 211R
Product TypeReaktif güç kontrol rölesi
Number of Steps12
Current InputTek faz akım girişi (1 akım trafosu)
Communication TypeRS-485 (Modbus RTU)
DisplayGrafik LCD
Harmonic Measurementup to 51th harmonic; THD-V and THD-I
Dynamic capacitor monitoringDCM var
Generator Input1 adet; 95–240 V AC, 45–65 Hz V AC
Number of Relay Outputs12 adet kompanzasyon NO (SPST), 2 A / 250 V AC, 500 VA; 2 adet alarm NO (SPST), 4 A / 250 V AC, 1000 VA
Current Range10 mA – 6 A AC
Voltage RangeL-N 95–410 V AC ±10%; L-L 95–410 V AC ±10%; 45–65 Hz
Supply Voltage95–410 V AC ±10% (La-Lb), 45–65 Hz
Power Consumption< 10 VA
Current Transformer Ratio1–5000
Target power factor0.8 kapasitif – 0.8 endüktif adjustable
Communication ProtocolModbus RTU; 2400–115200 bps; adres 1–247
Operating Temperature-20...+55 °C
Storage Temperature-30...+80 °C
Relative HumidityMax. 95% (non-condensing)
IP RatingÖn IP40 / arka IP20 (IP66 aksesuarla)
Mounting TypePanel montaj
Panel Cut-out144x144 mm
Gram663 g