Kraus & Naimer C316 T206/48 STM Emergency Stop Main Switch, 6-Pole, 275 A, in Enclosure (STM)
- Brand: Kraus & Naimer
- SKU: C316 T206/48 STM
- GTIN: 9004257070688
- MPN: C316 T206/48 STM
- Price: 217376.47 TRY + VAT · incl. VAT 260851.76 TRY
- Availability: Made to order
- Load Break Switches
- Kraus & Naimer Load Break Switches
- Selection guide: What Is a Load Break Switch? Types and Selection Criteria
Kraus & Naimer C316 T206/48 STM is a 6-pole emergency stop main switch rated 275 A (enclosed thermal current Ithe 275 A, open thermal current Ith 315 A) (red handle, yellow front plate); supplied as a maintenance and safety switch in a STM plastic enclosure with conduit entries, IP66/67, enclosure size 560 x 380 x 280 mm (oversized wiring space). Ratings: rated insulation voltage Ui 1000 V, impulse withstand voltage Uimp 8 kV, AC-21A 315 A, three-phase motor rating at 380–440 V: AC-3 55 kW, AC-23A 132 kW, breaking capacity 2000 / 2000 / 335 A (220–240 / 380–440 / 660–690 V), maximum fuse 315 A gG, short-time withstand current 4200 A (1 s). Connection: flexible conductors up to 150 mm², solid or stranded conductors up to 185 mm², terminal tightening torque 14 Nm. The enclosure has IP66/67 protection; a ground terminal and a safety interlocked cover are standard equipment. Codes ending in STM are supplied with conduit entries. This version is supplied with cable glands. It includes 1 NO + 1 NC auxiliary contacts; the auxiliary contacts close after the main contacts close and open before the main contacts open. The KG and C316 series switches exceed the requirements of IEC 60947-3 / EN 60947-3 (VDE 0660 part 107), IEC/EN 60204 and VDE 0113 and are used as switch disconnectors, main switches and maintenance switches.
| Number of Poles | 6P |
|---|---|
| Rated Current | 275 A |
| Mounting Type | STM ile kutulu (bakım and emniyet şalteri) |
| IP Rating | IP66/67 |
| Series | C316 |
| Size Type | S3 |
| Function Code | T206 |
| Switch Function | Acil Durdurma Fonksiyonlu Ana Şalter (0-1) |
| Switch Positions | 0-1 |
| Number of Positions | 2 |
| Handle Color | Red (sarı ön plaka) |
| Conventional Free Air Thermal Current (Ith) | 315 A |
| Ambient temperature for rated current | 55 °C (24 hours, tepe 60 °C) |
| Conventional Enclosed Thermal Current (Ithe) | 275 A |
| Rated Insulation Voltage (Ui) | 1000 V (AC 50/60 Hz and DC) |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Overvoltage category | III |
| Pollution Degree | 3 |
| Rated Operational Current AC-20A (Ie) | 1000 V: 315 A |
| Rated Operational Current AC-21A (Ie) | 20–690 V: 315 A |
| Rated Operational Current AC-22A (Ie) | 220–500 V: 315 A; 660–690 V: 125 A |
| Rated Operational Power AC-2 (Pe) | 3-phase: 220–240 V 55 kW; 380–440 V 90 kW; 500 V 110 kW; 660–690 V 55 kW |
| Rated Operational Power AC-3 (Pe) | 3-phase: 220–240 V 37 kW; 380–440 V 55 kW; 500 V 55 kW; 660–690 V 37 kW. 1-phase: 110–120 V 11 kW; 220–240 V 22 kW; 380–440 V 30 kW |
| Rated Operational Power AC-4 (Pe) | 3-phase: 220–240 V 15 kW; 380–440 V 25 kW; 500 V 25 kW; 660–690 V 22 kW. 1-phase: 110–120 V 4 kW; 220–240 V 7.5 kW; 380–440 V 11 kW |
| Rated Operational Power AC-23A (Pe) | 3-phase: 220–240 V 75 kW; 380–440 V 132 kW; 500 V 132 kW; 660–690 V 37 kW. 1-phase: 110–120 V 18.5 kW; 220–240 V 37 kW; 380–440 V 55 kW |
| Maximum Fuse Current | gG 315 A |
| Rated Short-Time Withstand Current (Icw) | 4200 A (1 s) |
| Breaking Capacity | 220–240 V: 2000 A; 380–440 V: 2000 A; 660–690 V: 335 A |
| Power Loss per Pole | 17 W |
| Solid Conductor Cable Cross-Section | 185 mm2 |
| Stranded Conductor Cable Cross-Section | 185 mm2 |
| Flexible Conductor Cross-Section | 150 mm2 |
| Cable section (AWG/MCM) | MCM 300 (flexible); MCM 350 (solid or stranded) |
| Conductor Material | Copper |
| Tightening Torque | 14 Nm (125 lb-in) |
| Recommended Screw Driver | anahtar M12 |
| Contact Type | Rigid bridging link |
| Contact Material | Silver |
| Connection Type | Cıvatalı terminal; kablo pabucu M12 vidayı alabilmeli |
| UL/CSA Rated Insulation Voltage (Ui) | 600 V AC |