Kraus & Naimer CG8 A201 On-Off Cam Switch, 2-Pole, 20 A, 48 x 48 mm Front Plate
- Brand: Kraus & Naimer
- SKU: CG8 A201
- MPN: CG8 A201
- Price: 1014.00 TRY + VAT · incl. VAT 1216.80 TRY
- Availability: Made to order
- On-Off Switches
- Kraus & Naimer On-Off Switches
- Selection guide: On-Off Cam Switches (0-1) Selection Guide
Kraus & Naimer CG8 A201 is a 20 A (Ith) CG8 series cam switch; function: 2-pole on-off (0-1) switch. Front plate 48 x 48 mm. Switching function: positions 0-1; switching angle 60°; 1 contact stage. Ratings: rated insulation voltage Ui 690 V, impulse withstand voltage Uimp 6 kV (switch), AC-21A 20 A, single-phase motor rating at 220–240 V: AC-3 2.2 kW, AC-23A 2.5 kW, breaking capacity 150 / 150 / 80 A (220–240 / 380–440 / 660–690 V), maximum fuse 25 A gG, short-time withstand current 140 A (1 s). Connection: flexible conductors 0.75–2.5 mm², solid or stranded conductors 0.5–2.5 mm², terminal tightening torque 0.6 Nm. It is used to switch a circuit on and off (0-1).
| Size Type | S0 |
|---|---|
| Number of Poles | 2P |
| Series | CG8 |
| Function Code | A201 |
| Switch Function | Aç-Kapa (0-1) |
| Switch Positions | 0-1 |
| Number of Positions | 2 |
| Switching Angle | 60° ° |
| Number of Levels | 1 |
| Front Plate Code | F070 |
| Front Plate Size (A x B) | 48 x 48 mm |
| Rated Current | 20 A |
| Conventional Free Air Thermal Current (Ith) | 20 A |
| Ambient temperature for rated current | 55 °C (24 hours, tepe 60 °C) |
| Conventional Enclosed Thermal Current (Ithe) | 20 A |
| Rated Insulation Voltage (Ui) | 690 V (AC 50/60 Hz and DC) |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV (circuit breaker) |
| Overvoltage category | III |
| Pollution Degree | 3 |
| Rated Operational Current AC-15 (Ie) | 110 V: 6 A; 220–240 V: 6 A; 380–440 V: 4 A |
| Rated Operational Current AC-20A (Ie) | 690 V: 20 A |
| Rated Operational Current AC-21A (Ie) | 20–690 V: 20 A |
| Rated Operational Current AC-22A (Ie) | 220–440 V: 20 A; 500 V: 20 A; 660–690 V: 16 A |
| Rated Operational Power AC-2 (Pe) | 3-phase: 220–240 V 4 kW; 380–440 V 7.5 kW; 500 V 10 kW; 660–690 V 10 kW |
| Rated Operational Power AC-3 (Pe) | 3-phase: 220–240 V 3 kW; 380–440 V 5.5 kW; 500 V 5.5 kW; 660–690 V 5.5 kW. 1-phase: 110–120 V 0.6 kW; 220–240 V 2.2 kW; 380–440 V 3 kW |
| Rated Operational Power AC-4 (Pe) | 3-phase: 220–240 V 0.55 kW; 380–440 V 1.5 kW; 500 V 1.5 kW; 660–690 V 1.5 kW. 1-phase: 110–120 V 0.3 kW; 220–240 V 0.75 kW; 380–440 V 1.5 kW |
| Rated Operational Power AC-23A (Pe) | 3-phase: 220–240 V 3.7 kW; 380–440 V 7.5 kW; 500 V 7.5 kW; 660–690 V 7.5 kW. 1-phase: 110–120 V 0.75 kW; 220–240 V 2.5 kW; 380–440 V 3.7 kW |
| Maximum Fuse Current | gG 25 A |
| Rated Short-Time Withstand Current (Icw) | 140 A (1 s) |
| Breaking Capacity | 220–240 V: 150 A; 380–440 V: 150 A; 660–690 V: 80 A |
| Power Loss per Pole | 0.8 W |
| Solid Conductor Cable Cross-Section | 0.5–2.5 mm2 |
| Stranded Conductor Cable Cross-Section | 2x2.5 mm2 |
| Flexible Conductor Cross-Section | 0.75–2.5 mm2 |
| Conductor Cross-Section with Ferrule | 0.5–2.5 mm2 |
| Cable section (AWG/MCM) | AWG 14 (flexible); AWG 12 (solid or stranded) |
| Conductor Material | Copper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered) |
| Tightening Torque | 0.6 Nm (5 lb-in) |
| Recommended Screw Driver | Pozidriv/Phillips PH1; slotted 0.8 x 4 mm (DIN 5264) |
| Contact Type | Rigid bridging link |
Shipping & assurance
For made-to-order products, the procurement and carrier hand-over time is shared with the quotation.
In rare cases, all or part of an order may be unavailable due to stock or procurement updates. In this case, the customer is informed and the relevant product is cancelled and refunded. A product being open for sale does not guarantee that it is in physical store stock.