Kraus & Naimer KG10A T203/68 VE Emergency Stop Main Switch, 3-Pole, 20 A, 48 x 48 mm Front Plate

Kraus & Naimer KG10A T203/68 VE Emergency Stop Main Switch, 3-Pole, 20 A, 48 x 48 mm Front Plate

Kraus & Naimer KG10A T203/68 VE is a 20 A (Ith), 3-pole emergency stop main switch (red handle, yellow front plate); base mounting with simplified door clutch and padlock device (single hole 22 mm), 48 x 48 mm escutcheon plate, IP66. Ratings: rated insulation voltage Ui 690 V, impulse withstand voltage Uimp 4 kV, AC-21A 20 A, three-phase motor rating at 380–440 V: AC-3 3.7 kW, AC-23A 5.5 kW, breaking capacity 120 / 120 / 80 A (220–240 / 380–440 / 660–690 V), maximum fuse 20 A gG or C16 LSS (400 V, 16 A), short-time withstand current 130 A (1 s). Connection: flexible conductors 0.75–2.5 mm², solid or stranded conductors 0.5–2.5 mm², terminal tightening torque 0.6 Nm. The KG and C316 series switches exceed the requirements of IEC 60947-3 / EN 60947-3 (VDE 0660 part 107), IEC/EN 60204 and VDE 0113 and are used as switch disconnectors, main switches and maintenance switches.

Number of Poles3P
Rated Current20 A
Mounting TypeVE taban montajı, basitleştirilmiş kapı kavraması, asma kilit aparatı, tek delik 22 mm
IP RatingIP66
SeriesKG10A
Size TypeS0
Function CodeT203
Switch FunctionAcil Durdurma Fonksiyonlu Ana Şalter (0-1)
Switch Positions0-1
Number of Positions2
Front Plate Size (A x B)48 x 48 mm
Handle ColorRed (sarı ön plaka)
Conventional Free Air Thermal Current (Ith)20 A
Ambient temperature for rated current50 °C (24 hours, tepe 55 °C)
Conventional Enclosed Thermal Current (Ithe)20 A
Rated Insulation Voltage (Ui)690 V (AC 50/60 Hz)
Rated Impulse Withstand Voltage (Uimp)4 kV
Overvoltage categoryII
Pollution Degree3
Rated Operational Current AC-15 (Ie)220–240 V: 6 A; 380–440 V: 4 A
Rated Operational Current AC-20A (Ie)690 V: 20 A
Rated Operational Current AC-21A (Ie)20–690 V: 20 A
Rated Operational Current AC-22A (Ie)220–500 V: 20 A; 660–690 V: 16 A
Rated Operational Power AC-3 (Pe)3-phase: 220–240 V 2.2 kW; 380–440 V 3.7 kW; 500 V 3.7 kW; 660–690 V 3.7 kW. 1-phase: 220–240 V 1.1 kW; 380–440 V 1.5 kW
Rated Operational Power AC-23A (Pe)3-phase: 220–240 V 3 kW; 380–440 V 5.5 kW; 500 V 5.5 kW; 660–690 V 5.5 kW. 1-phase: 220–240 V 1.5 kW; 380–440 V 2.2 kW
Maximum Fuse CurrentgG 20 A; C16 LSS 400 V: 16 A
Rated Short-Time Withstand Current (Icw)130 A (1 s)
Breaking Capacity220–240 V: 120 A; 380–440 V: 120 A; 660–690 V: 80 A
Power Loss per Pole0.9 W
Solid Conductor Cable Cross-Section0.5–2.5 mm2
Stranded Conductor Cable Cross-Section2.5 mm2
Flexible Conductor Cross-Section0.75–2.5 mm2
Conductor Cross-Section with Ferrule0.5–2.5 mm2
Cable section (AWG/MCM)AWG 12
Conductor MaterialCopper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered)
Tightening Torque0.6 Nm (5 lb-in)
Recommended Screw DriverPozidriv/Phillips PH1; slotted 0.8 x 4 mm (DIN 5264)
Contact TypeRigid bridging link
Contact MaterialSilver
Connection TypeScrew terminal