A limit switch is a position switch that changes its contact state when a moving machine part touches its actuator. It detects end of travel, stops a motor or reports position to the control system. Contact properties are defined in IEC 60947-5-1; actuator type, contact arrangement and protection rating decide the choice.

> Related Category: Browse models by actuator and housing in Limit Switches, Safety Limit Switches and Micro and Miniature Switches.

1. Types by actuator

ActuatorOperating directionUse
PlungerStraight push along the axisPrecise position, cover and door detection
Roller plungerAxial, via cam or rampSliding parts
Roller leverFrom the side, 30–45° rotationConveyors, cranes, doors; the most common type
Adjustable roller leverLever length and angle adjustableParts passing at different heights
Adjustable rodSide contact on a long rodWide-tolerance detection
Spring rod (wobble stick)Contact from any directionIrregular parts, uncertain direction
Fork leverMaintained in two positionsReversing in back-and-forth motion

On roller types the ramp angle should not exceed 30° and the part must not push the actuator past its permitted overtravel, or the head breaks.

2. Contacts: NO, NC and action type

A standard limit switch has one normally open (NO, 13-14) and one normally closed (NC, 21-22) contact.

Contact actionBehaviourUse
Snap actionAt a set point NC opens and NO closes together, independent of actuator speedSlow-moving parts, general control
Slow actionContacts follow the actuator; NC opens first, NO closes laterSafety circuits, sequenced switching

Positive opening: the NC contact is forced open directly by the actuator, with no spring in between, so it separates even if welded. Any limit switch used for a safety function must have it, shown by an arrow-in-circle symbol on the housing.

3. Limit switch wiring diagram

End-of-travel stop with a contactor (NC contact):

Control line → stop button → limit switch NC (21-22) → start button with holding contact → contactor coil A1; A2 → neutral

When the part reaches the end and presses the actuator, the NC contact opens, the coil drops out and the motor stops. In reversing systems each direction has its own switch: the forward limit in series with the forward contactor coil, the reverse limit with the reverse coil, so travel away from the limit stays possible. For the holding logic see Contactor Latching Circuit.

Position signal to a PLC (NO contact):

+24 V → limit switch NO (13-14) → PLC digital input

4. Limit switch families compared

TypePropertyUse
Standard limit switchMetal or plastic housing, IP65–IP67, exchangeable headMachines, conveyors, doors
Safety limit switchPositive-opening NC, separate tongue or hinge designGuard and door interlocking
Micro switchSmall body, low operating force, fast responseInside devices, lid detection, appliances
Rotary limit switchCam contacts set by shaft revolutionsHoist limits, shutters, blind motors

5. Limit switch or sensor?

PropertyLimit switchInductive sensor
DetectionMechanical contactContactless, metal only
OutputDry contact; AC and DC, higher currentTransistor (NPN / PNP), low current
SupplyNone needed10–30 V DC
LifeMechanical wear (millions of operations)No wear
Switching rateLowHigh
StrengthSimple, drives a contactor coil directly, safety circuitsDirty areas, fast and frequent detection

Sensor wiring is covered in Inductive, Capacitive and Photoelectric Sensor NPN vs PNP Wiring.

6. Selection criteria

Frequently asked questions

What does a limit switch do?

It detects by mechanical contact that a moving part has reached a set position, then stops the motor, reverses it or signals the control system.

Is a limit switch wired NO or NC?

Use the NC contact for stopping and safety, so a broken wire also stops the machine. If only position information is needed, wire the NO contact to a PLC input.

What is the difference between a limit switch and a micro switch?

A limit switch is a rugged IP65–IP67 position switch used on machines. A micro switch is a small, low-force contact element mounted inside equipment.

What sets a safety limit switch apart from a standard one?

A positive-opening NC contact and a design that resists defeat. Even with welded contacts the actuator movement opens the circuit; guards require this type.

Why do limit switches fail?

Most often from being pushed past overtravel, too steep a ramp, water or oil entering at the cable entry, and switching current above the contact rating.