Kraus & Naimer C32 A200/TRA201 On-Off Cam Switch, 1-Pole, 50 A, in Enclosure (KE02)
- Brand: Kraus & Naimer
- SKU: C32 A200/TRA201
- MPN: C32 A200/TRA201
- Model: 50 A
- Price: 2555.00 TRY + VAT · incl. VAT 3066.00 TRY
- Availability: Made to order
- On-Off Switches
- Kraus & Naimer On-Off Switches
- Selection guide: On-Off Cam Switches (0-1) Selection Guide
Kraus & Naimer C32 A200/TRA201 is a 1-pole, 50 An on-off cam switch. The switch has positions 0-1, a switching angle of 60° and 1 level. It is supplied as an enclosed (TRA) version in a KE02 enclosure (IP65) with an I handle. Front plate code F070; size type S1. Rated insulation voltage is 690 V (AC 50/60 Hz) and rated impulse withstand voltage is 6 kV. AC-21A rated operational current is 40 A over 20–690 V. Maximum fuse rating gG 63 A; rated short-time withstand current 800 A (1 s); power loss per pole 1.3 W. The terminals accept stranded conductors up to 2 x 10 mm²; tightening torque is 2.2 Nm (19.5 lb-in); operating temperature is -25…+60 °C. It is used to switch a circuit on and off manually.
| Size Type | S1 |
|---|---|
| Number of Poles | 1P |
| Series | C32 |
| Function Code | A200 |
| Switch Function | Aç-Kapa (0-1) |
| Switch Positions | 0-1 |
| Number of Positions | 2 |
| Switching Angle | 60° ° |
| Number of Levels | 1 |
| Front Plate Code | F070 |
| Rated Current | 50 A |
| Conventional Free Air Thermal Current (Ith) | 50 A |
| Ambient temperature for rated current | 55 °C (24 hours, tepe 60 °C) |
| Conventional Enclosed Thermal Current (Ithe) | 50 A |
| Rated Insulation Voltage (Ui) | 690 V (AC 50/60 Hz) |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Overvoltage category | III |
| Pollution Degree | 3 |
| Rated Operational Current AC-15 (Ie) | 220–240 V: 16 A; 380–440 V: 7 A |
| Rated Operational Current AC-20A (Ie) | 690 V: 50 A |
| Rated Operational Current AC-21A (Ie) | 20–690 V: 40 A |
| Rated Operational Current AC-22A (Ie) | 220–500 V: 40 A; 660–690 V: 40 A |
| Rated Operational Power AC-2 (Pe) | 3-phase: 220–240 V 10 kW; 380–440 V 18.5 kW; 500 V 22 kW; 660–690 V 22 kW |
| Rated Operational Power AC-3 (Pe) | 3-phase: 220–240 V 7.5 kW; 380–440 V 15 kW; 500 V 15 kW; 660–690 V 15 kW. 1-phase: 110–120 V 2.5 kW; 220–240 V 5.5 kW; 380–440 V 7.5 kW |
| Rated Operational Power AC-4 (Pe) | 3-phase: 220–240 V 3.7 kW; 380–440 V 6 kW; 500 V 6 kW; 660–690 V 6 kW. 1-phase: 110–120 V 1.1 kW; 220–240 V 2.2 kW; 380–440 V 3.7 kW |
| Rated Operational Power AC-23A (Pe) | 3-phase: 220–240 V 11 kW; 380–440 V 22 kW; 500 V 30 kW; 660–690 V 22 kW. 1-phase: 110–120 V 2.5 kW; 220–240 V 5.5 kW; 380–440 V 11 kW |
| Maximum Fuse Current | gG 63 A |
| Rated Short-Time Withstand Current (Icw) | 800 A (1 s) |
| Breaking Capacity | 220–240 V: 380 A; 380–440 V: 360 A; 660–690 V: 270 A |
| Power Loss per Pole | 1.3 W |
| Solid Conductor Cable Cross-Section | 1–10 mm2 |
| Stranded Conductor Cable Cross-Section | 2x10 mm2 |
| Flexible Conductor Cross-Section | 1.5–6 mm2 |
| Conductor Cross-Section with Ferrule | 1–6 mm2 |
| Cable section (AWG/MCM) | AWG 8 |
| Conductor Material | Copper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered) |
| Tightening Torque | 2.2 Nm (19.5 lb-in) |
| Recommended Screw Driver | Pozidriv/Phillips PH2; slotted 1.2 x 8 mm (DIN 5264) |
| Contact Type | Rigid bridging link |
| Contact Material | Silver |
Shipping & assurance
For made-to-order products, the procurement and carrier hand-over time is shared with the quotation.
In rare cases, all or part of an order may be unavailable due to stock or procurement updates. In this case, the customer is informed and the relevant product is cancelled and refunded. A product being open for sale does not guarantee that it is in physical store stock.