Kraus & Naimer CA10 T202/01 E S0 Emergency Stop Main Switch, 2-Pole, 20 A, 48 x 48 mm Front Plate

Kraus & Naimer CA10 T202/01 E S0 Emergency Stop Main Switch, 2-Pole, 20 A, 48 x 48 mm Front Plate

Kraus & Naimer CA10 T202/01 E S0 is a 20 A (Ith), 2-pole emergency stop main switch (lockable, red handle, yellow front plate); E S0 mounting (four-hole panel, size S0), 48 x 48 mm front plate, IP40. Ratings: rated insulation voltage Ui 690 V, impulse withstand voltage Uimp 6 kV (switch) / 4 kV (switch disconnector), AC-21A 20 A, single-phase motor rating at 220–240 V: AC-3 2.2 kW, AC-23A 2.5 kW, breaking capacity 150 / 150 / 80 A (220–240 / 380–440 / 660–690 V), maximum fuse 25 A gG, short-time withstand current 140 A (1 s). Connection: flexible conductors 0.75–2.5 mm², solid or stranded conductors 0.5–2.5 mm², terminal tightening torque 0.6 Nm. It is used as a two-phase 0-1 main switch; this is the yellow-red lockable version.

Number of Poles2P
Rated Current20 A
Mounting TypeE montajı: dört delikli panel
IP RatingIP40
SeriesCA10
Size TypeS0
Function CodeT202
Switch FunctionAcil Durdurma Fonksiyonlu Ana Şalter (0-1)
Switch Positions0-1
Number of Positions2
Front Plate Size (A x B)48 x 48 mm
Handle ColorRed (sarı ön plaka)
Conventional Free Air Thermal Current (Ith)20 A
Ambient temperature for rated current55 °C (24 hours, tepe 60 °C)
Conventional Enclosed Thermal Current (Ithe)20 A
Rated Insulation Voltage (Ui)690 V (AC 50/60 Hz and DC)
Rated Impulse Withstand Voltage (Uimp)6 kV (circuit breaker); 4 kV (switch-disconnector)
Overvoltage categoryIII
Pollution Degree3
Rated Operational Current AC-15 (Ie)220–240 V: 6 A; 380–440 V: 4 A
Rated Operational Current AC-20A (Ie)690 V: 20 A
Rated Operational Current AC-21A (Ie)20–690 V: 20 A
Rated Operational Current AC-22A (Ie)220–500 V: 20 A; 660–690 V: 20 A
Rated Operational Power AC-2 (Pe)3-phase: 220–240 V 4 kW; 380–440 V 7.5 kW; 500 V 10 kW; 660–690 V 10 kW
Rated Operational Power AC-3 (Pe)3-phase: 220–240 V 3 kW; 380–440 V 5.5 kW; 500 V 5.5 kW; 660–690 V 5.5 kW. 1-phase: 110–120 V 0.6 kW; 220–240 V 2.2 kW; 380–440 V 3 kW
Rated Operational Power AC-4 (Pe)3-phase: 220–240 V 0.55 kW; 380–440 V 1.5 kW; 500 V 1.5 kW; 660–690 V 1.5 kW. 1-phase: 110–120 V 0.3 kW; 220–240 V 0.75 kW; 380–440 V 1.5 kW
Rated Operational Power AC-23A (Pe)3-phase: 220–240 V 3.7 kW; 380–440 V 7.5 kW; 500 V 7.5 kW; 660–690 V 7.5 kW. 1-phase: 110–120 V 0.75 kW; 220–240 V 2.5 kW; 380–440 V 3.7 kW
Maximum Fuse CurrentgG 25 A
Rated Short-Time Withstand Current (Icw)140 A (1 s)
Breaking Capacity220–240 V: 150 A; 380–440 V: 150 A; 660–690 V: 80 A
Power Loss per Pole0.9 W
Solid Conductor Cable Cross-Section0.5–2.5 mm2
Stranded Conductor Cable Cross-Section2x2.5 mm2
Flexible Conductor Cross-Section0.75–2.5 mm2
Conductor Cross-Section with Ferrule0.5–2.5 mm2
Cable section (AWG/MCM)AWG 14 (flexible); AWG 12 (solid or stranded)
Conductor MaterialCopper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered)
Tightening Torque0.6 Nm (5 lb-in)
Recommended Screw DriverPozidriv/Phillips PH1; slotted 0.8 x 4 mm (DIN 5264)
Contact TypeRigid bridging link