Kraus & Naimer CA20 A202 On-Off Cam Switch, 3-Pole, 25 A, 48 x 48 mm Front Plate
- Brand: Kraus & Naimer
- SKU: CA20 A202
- MPN: CA20 A202
- Model: 25 A
- Price: 1433.00 TRY + VAT · incl. VAT 1719.60 TRY
- Availability: In stock
- On-Off Switches
- Kraus & Naimer On-Off Switches
- Selection guide: On-Off Cam Switches (0-1) Selection Guide
Kraus & Naimer CA20 A202 is a 3-pole on-off (0-1) cam switch rated 25 A. The CA20 type switch has a 48 x 48 mm front plate; Ith 25 A, Ui 690 V; three-phase motor rating at 380–440 V is 7.5 kW (AC-3) and 11 kW (AC-23A); rated short-time withstand current Icw is 280 A (1 s); terminals accept conductors up to 4 mm². Function: 3 poles, 2 positions (0-1), 60° switching angle, 2 stages. It is an on-off switch used to open and close a circuit or load; all poles are opened and closed together by a single handle.
| Size Type | S0 |
|---|---|
| Number of Poles | 3P |
| Series | CA20 |
| Function Code | A202 |
| Switch Function | Aç-Kapa (0-1) |
| Switch Positions | 0-1 |
| Number of Positions | 2 |
| Switching Angle | 60° ° |
| Number of Levels | 2 |
| Front Plate Code | F070 |
| Front Plate Size (A x B) | 48 x 48 mm |
| Rated Current | 25 A |
| Conventional Free Air Thermal Current (Ith) | 25 A |
| Ambient temperature for rated current | 55 °C (24 hours, tepe 60 °C) |
| Conventional Enclosed Thermal Current (Ithe) | 25 A |
| Rated Insulation Voltage (Ui) | 690 V (AC 50/60 Hz and DC) |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Overvoltage category | III |
| Pollution Degree | 3 |
| Rated Operational Current AC-15 (Ie) | 220–240 V: 8 A; 380–440 V: 5 A |
| Rated Operational Current AC-20A (Ie) | 690 V: 25 A |
| Rated Operational Current AC-21A (Ie) | 20–690 V: 25 A |
| Rated Operational Current AC-22A (Ie) | 220–500 V: 25 A; 660–690 V: 25 A |
| Rated Operational Power AC-2 (Pe) | 3-phase: 220–240 V 5.5 kW; 380–440 V 11 kW; 500 V 15 kW; 660–690 V 13 kW |
| Rated Operational Power AC-3 (Pe) | 3-phase: 220–240 V 4 kW; 380–440 V 7.5 kW; 500 V 7.5 kW; 660–690 V 7.5 kW. 1-phase: 110–120 V 1.5 kW; 220–240 V 3 kW; 380–440 V 3.7 kW |
| Rated Operational Power AC-4 (Pe) | 3-phase: 220–240 V 1.5 kW; 380–440 V 3 kW; 500 V 3 kW; 660–690 V 3 kW. 1-phase: 110–120 V 0.45 kW; 220–240 V 1.1 kW; 380–440 V 2.2 kW |
| Rated Operational Power AC-23A (Pe) | 3-phase: 220–240 V 5.5 kW; 380–440 V 11 kW; 500 V 11 kW; 660–690 V 11 kW. 1-phase: 110–120 V 1.5 kW; 220–240 V 3 kW; 380–440 V 5.5 kW |
| Maximum Fuse Current | gG 35 A |
| Rated Short-Time Withstand Current (Icw) | 280 A (1 s) |
| Breaking Capacity | 220–240 V: 200 A; 380–440 V: 200 A; 660–690 V: 125 A |
| Power Loss per Pole | 0.9 W |
| Solid Conductor Cable Cross-Section | 0.75–4 mm2 |
| Stranded Conductor Cable Cross-Section | 2x4 mm2 |
| Flexible Conductor Cross-Section | 1.5–4 mm2 |
| Conductor Cross-Section with Ferrule | 1–2.5 mm2 |
| Cable section (AWG/MCM) | AWG 12 (flexible); AWG 10 (solid or stranded) |
| Conductor Material | Copper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered) |
| Tightening Torque | 1 Nm (9 lb-in) |
| Recommended Screw Driver | Pozidriv/Phillips PH1; slotted 0.8 x 5.5 mm (DIN 5264) |
| Contact Type | Rigid bridging link |