Kraus & Naimer KG10B T203/01 E Emergency Stop Main Switch, 3-Pole, 20 A, 64 x 64 mm Front Plate
- Brand: Kraus & Naimer
- SKU: KG10B T203/01 E
- GTIN: 9004257010493
- MPN: KG10B T203/01 E
- Model: 20 A
- Price: 2093.13 TRY + VAT · incl. VAT 2511.76 TRY
- Availability: Made to order
- Load Break Switches
- Kraus & Naimer Load Break Switches
- Selection guide: What Is a Load Break Switch? Types and Selection Criteria
Kraus & Naimer KG10B T203/01 E is a 20 A (Ith), 3-pole emergency stop main switch (red handle, yellow front plate); four-hole panel mounting, 64 x 64 mm front plate, IP66. Ratings: rated insulation voltage Ui 690 V, impulse withstand voltage Uimp 4 kV, AC-21A 20 A, three-phase motor rating at 380–440 V: AC-3 3.7 kW, AC-23A 5.5 kW, breaking capacity 120 / 120 / 80 A (220–240 / 380–440 / 660–690 V), maximum fuse 20 A gG or C16 LSS (400 V, 16 A), short-time withstand current 130 A (1 s). Connection: flexible conductors 0.75–2.5 mm², solid or stranded conductors 0.5–2.5 mm², terminal tightening torque 0.6 Nm. The KG and C316 series switches exceed the requirements of IEC 60947-3 / EN 60947-3 (VDE 0660 part 107), IEC/EN 60204 and VDE 0113 and are used as switch disconnectors, main switches and maintenance switches.
| Number of Poles | 3P |
|---|---|
| Rated Current | 20 A |
| Mounting Type | E montajı: dört delikli panel |
| IP Rating | IP66 |
| Series | KG10B |
| Size Type | S0 |
| Function Code | T203 |
| Switch Function | Acil Durdurma Fonksiyonlu Ana Şalter (0-1) |
| Switch Positions | 0-1 |
| Number of Positions | 2 |
| Front Plate Size (A x B) | 64 x 64 mm |
| Handle Color | Red (sarı ön plaka) |
| Conventional Free Air Thermal Current (Ith) | 20 A |
| Ambient temperature for rated current | 50 °C (24 hours, tepe 55 °C) |
| Conventional Enclosed Thermal Current (Ithe) | 20 A |
| Rated Insulation Voltage (Ui) | 690 V (AC 50/60 Hz) |
| Rated Impulse Withstand Voltage (Uimp) | 4 kV |
| Overvoltage category | II |
| Pollution Degree | 3 |
| Rated Operational Current AC-15 (Ie) | 220–240 V: 6 A; 380–440 V: 4 A |
| Rated Operational Current AC-20A (Ie) | 690 V: 20 A |
| Rated Operational Current AC-21A (Ie) | 20–690 V: 20 A |
| Rated Operational Current AC-22A (Ie) | 220–500 V: 20 A; 660–690 V: 16 A |
| Rated Operational Power AC-3 (Pe) | 3-phase: 220–240 V 2.2 kW; 380–440 V 3.7 kW; 500 V 3.7 kW; 660–690 V 3.7 kW. 1-phase: 220–240 V 1.1 kW; 380–440 V 1.5 kW |
| Rated Operational Power AC-23A (Pe) | 3-phase: 220–240 V 3 kW; 380–440 V 5.5 kW; 500 V 5.5 kW; 660–690 V 5.5 kW. 1-phase: 220–240 V 1.5 kW; 380–440 V 2.2 kW |
| Maximum Fuse Current | gG 20 A; C16 LSS 400 V: 16 A |
| Rated Short-Time Withstand Current (Icw) | 130 A (1 s) |
| Breaking Capacity | 220–240 V: 120 A; 380–440 V: 120 A; 660–690 V: 80 A |
| Power Loss per Pole | 0.9 W |
| Solid Conductor Cable Cross-Section | 0.5–2.5 mm2 |
| Stranded Conductor Cable Cross-Section | 2.5 mm2 |
| Flexible Conductor Cross-Section | 0.75–2.5 mm2 |
| Conductor Cross-Section with Ferrule | 0.5–2.5 mm2 |
| Cable section (AWG/MCM) | AWG 12 |
| Conductor Material | Copper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered) |
| Tightening Torque | 0.6 Nm (5 lb-in) |
| Recommended Screw Driver | Pozidriv/Phillips PH1; slotted 0.8 x 4 mm (DIN 5264) |
| Contact Type | Rigid bridging link |
| Contact Material | Silver |
| Connection Type | Screw terminal |