Kraus & Naimer KG250 T204/13 VE Emergency Stop Main Switch, 4-Pole, 250 A, 88 x 88 mm Front Plate
- Brand: Kraus & Naimer
- SKU: KG250 T204/13 VE
- GTIN: 9004257003471
- MPN: KG250 T204/13 VE
- Model: 250 A
- Price: 36698.10 TRY + VAT · incl. VAT 44037.72 TRY
- Availability: Made to order
- Load Break Switches
- Kraus & Naimer Load Break Switches
- Selection guide: What Is a Load Break Switch? Types and Selection Criteria
Kraus & Naimer KG250 T204/13 VE is a 250 A (Ith), 4-pole emergency stop main switch (red handle, yellow front plate); base mounting with door clutch, 88 x 88 mm escutcheon plate, IP66. Ratings: rated insulation voltage Ui 1000 V, impulse withstand voltage Uimp 8 kV, AC-21A 250 A, three-phase motor rating at 380–440 V: AC-3 55 kW, AC-23A 90 kW, breaking capacity 1600 / 1380 / 400 A (220–240 / 380–440 / 660–690 V), maximum fuse 250 A gG, short-time withstand current 4600 A (1 s). Connection: flexible conductors 25–150 mm², solid or stranded conductors 16–185 mm², terminal tightening torque 16 Nm. Versions with door clutch are also supplied with a padlock device. The panel door can only be opened when the switch is in the OFF position and no padlock is fitted. A padlockable handle and a protective cover for the incoming terminals are standard equipment. KG250 and KG315 also have protective covers on the outgoing terminals. The KG and C316 series switches exceed the requirements of IEC 60947-3 / EN 60947-3 (VDE 0660 part 107), IEC/EN 60204 and VDE 0113 and are used as switch disconnectors, main switches and maintenance switches.
| Number of Poles | 4P |
|---|---|
| Rated Current | 250 A |
| Mounting Type | VE taban montajı, kapı kavramalı |
| IP Rating | IP66 |
| Series | KG250 |
| Size Type | S2 |
| Function Code | T204 |
| Switch Function | Acil Durdurma Fonksiyonlu Ana Şalter (0-1) |
| Switch Positions | 0-1 |
| Number of Positions | 2 |
| Front Plate Size (A x B) | 88 x 88 mm |
| Handle Color | Red (sarı ön plaka) |
| Conventional Free Air Thermal Current (Ith) | 250 A |
| Ambient temperature for rated current | 50 °C (24 hours, tepe 55 °C) |
| Conventional Enclosed Thermal Current (Ithe) | 250 A |
| Rated Insulation Voltage (Ui) | 1000 V (AC 50/60 Hz) |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Overvoltage category | III |
| Pollution Degree | 3 |
| Rated Operational Current AC-20A (Ie) | 1000 V: 250 A |
| Rated Operational Current AC-21A (Ie) | 20–690 V: 250 A |
| Rated Operational Current AC-22A (Ie) | 220–500 V: 200 A; 660–690 V: 125 A |
| Rated Operational Power AC-3 (Pe) | 3-phase: 220–240 V 37 kW; 380–440 V 55 kW; 500 V 75 kW; 660–690 V 40 kW |
| Rated Operational Power AC-23A (Pe) | 3-phase: 220–240 V 37 kW; 380–440 V 90 kW; 500 V 110 kW; 660–690 V 45 kW |
| Maximum Fuse Current | gG 250 A |
| Rated Short-Time Withstand Current (Icw) | 4600 A (1 s) |
| Breaking Capacity | 220–240 V: 1600 A; 380–440 V: 1380 A; 660–690 V: 400 A |
| Power Loss per Pole | 8 W |
| Solid Conductor Cable Cross-Section | 16–185 mm2 |
| Stranded Conductor Cable Cross-Section | 185 mm2 |
| Flexible Conductor Cross-Section | 25–150 mm2 |
| Conductor Cross-Section with Ferrule | 16–120 mm2 |
| Cable section (AWG/MCM) | MCM 300 (flexible); MCM 350 (solid or stranded) |
| Conductor Material | Copper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered) |
| Tightening Torque | 16 Nm (140 lb-in) |
| Recommended Screw Driver | alyan anahtar 6 mm |
| Contact Type | Rigid bridging link |
| Contact Material | Silver |
| Connection Type | Screw terminal |
| UL/CSA Rated Insulation Voltage (Ui) | 600 V AC |