Kraus & Naimer KG80 T203/33 KL71V Emergency Stop Main Switch, 3-Pole, 80 A, in Enclosure (KL71V)

Kraus & Naimer KG80 T203/33 KL71V Emergency Stop Main Switch, 3-Pole, 80 A, in Enclosure (KL71V)

Kraus & Naimer KG80 T203/33 KL71V is an 80 A (Ith), 3-pole emergency stop main switch (red handle, yellow front plate); supplied as a maintenance and safety switch in a KL series plastic enclosure (KL71V), IP66/67. Ratings: rated insulation voltage Ui 690 V, impulse withstand voltage Uimp 6 kV, AC-21A 80 A, three-phase motor rating at 380–440 V: AC-3 22 kW, AC-23A 30 kW, breaking capacity 560 / 560 / 200 A (220–240 / 380–440 / 660–690 V), maximum fuse 80 A gG, short-time withstand current 1600 A (1 s). Connection: flexible conductors 4–35 mm², solid or stranded conductors 2.5–50 mm², terminal tightening torque 3 Nm. The enclosure has IP66/67 protection and is flame resistant to UL94 V-0; a ground terminal and a safety interlocked cover are standard equipment. The KG and C316 series switches exceed the requirements of IEC 60947-3 / EN 60947-3 (VDE 0660 part 107), IEC/EN 60204 and VDE 0113 and are used as switch disconnectors, main switches and maintenance switches.

Number of Poles3P
Rated Current80 A
Mounting TypeKL71V ile kutulu (bakım and emniyet şalteri)
IP RatingIP66/67
SeriesKG80
Size TypeS1
Function CodeT203
Switch FunctionAcil Durdurma Fonksiyonlu Ana Şalter (0-1)
Switch Positions0-1
Number of Positions2
Handle ColorRed (sarı ön plaka)
Conventional Free Air Thermal Current (Ith)80 A
Ambient temperature for rated current50 °C (24 hours, tepe 55 °C)
Conventional Enclosed Thermal Current (Ithe)80 A
Rated Insulation Voltage (Ui)690 V (AC 50/60 Hz)
Rated Impulse Withstand Voltage (Uimp)6 kV
Overvoltage categoryIII
Pollution Degree3
Rated Operational Current AC-20A (Ie)690 V: 80 A
Rated Operational Current AC-21A (Ie)20–690 V: 80 A
Rated Operational Current AC-22A (Ie)220–500 V: 80 A; 660–690 V: 65 A
Rated Operational Power AC-3 (Pe)3-phase: 220–240 V 15 kW; 380–440 V 22 kW; 500 V 30 kW; 660–690 V 18.5 kW
Rated Operational Power AC-23A (Pe)3-phase: 220–240 V 18.5 kW; 380–440 V 30 kW; 500 V 37 kW; 660–690 V 22 kW
Maximum Fuse CurrentgG 80 A
Rated Short-Time Withstand Current (Icw)1600 A (1 s)
Breaking Capacity220–240 V: 560 A; 380–440 V: 560 A; 660–690 V: 200 A
Power Loss per Pole1.7 W
Solid Conductor Cable Cross-Section2.5–50 mm2
Stranded Conductor Cable Cross-Section50 mm2
Flexible Conductor Cross-Section4–35 mm2
Conductor Cross-Section with Ferrule2.5–35 mm2
Cable section (AWG/MCM)AWG 2 (flexible); AWG 10–1/0 (solid or stranded)
Conductor MaterialCopper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered)
Tightening Torque3 Nm (27 lb-in)
Recommended Screw DriverPozidriv/Phillips PH2; slotted 1.2 x 6.5 mm (DIN 5264)
Contact TypeRigid bridging link
Contact MaterialSilver
Connection TypeScrew terminal
UL/CSA Rated Insulation Voltage (Ui)600 V AC
UL/CSA Thermal Current80 A