Kraus & Naimer C26 A311 Group Cam Switch, 1-Pole, 32 A, 64 x 64 mm Front Plate

Kraus & Naimer C26 A311 Group Cam Switch, 1-Pole, 32 A, 64 x 64 mm Front Plate

Kraus & Naimer C26 A311 is a 1-pole, 32 A group cam switch with 3 load groups and positions 0, A, A+B, A+B+C. Technical values: C26 type, size class S1, 64 x 64 mm front plate; thermal current Ith 32 A (55 °C), enclosed thermal current Ithe 32 A; rated insulation voltage Ui 690 V, rated impulse withstand voltage Uimp 6 kV; AC-21A 32 A, AC-22A 32 A, AC-15 380–440 V 6 A; maximum gG 50 A fuse, Icw 350 A (1 s); conductor cross-section: solid 1–6 mm², flexible 1.5–6 mm²; tightening torque 1.3 Nm; 1 pole, 2 levels, positions 0, A, A+B, A+B+C, switching angle 30°. Values are given in accordance with IEC 60947-3 and EN 60947-3. It is used to switch load groups A, B and C on in sequence: all groups are switched off in position 0, followed by groups A, A+B and A+B+C.

SeriesC26
Size TypeS1
Function CodeA311
Switch FunctionGrup Şalteri (0-A-A+B-A+B+C)
Switch Positions0-A-A+B-A+B+C
Number of Positions4
Switching Angle30° °
Number of Poles1P
Number of Levels2
Front Plate CodeF001
Front Plate Size (A x B)64 x 64 mm
Rated Current32 A
Conventional Free Air Thermal Current (Ith)32 A
Ambient temperature for rated current55 °C (24 hours, tepe 60 °C)
Conventional Enclosed Thermal Current (Ithe)32 A
Rated Insulation Voltage (Ui)690 V (AC 50/60 Hz)
Rated Impulse Withstand Voltage (Uimp)6 kV
Overvoltage categoryIII
Pollution Degree3
Rated Operational Current AC-15 (Ie)220–240 V: 14 A; 380–440 V: 6 A
Rated Operational Current AC-20A (Ie)690 V: 32 A
Rated Operational Current AC-21A (Ie)20–690 V: 32 A
Rated Operational Current AC-22A (Ie)220–500 V: 32 A; 660–690 V: 32 A
Rated Operational Power AC-2 (Pe)3-phase: 220–240 V 8 kW; 380–440 V 15 kW; 500 V 18.5 kW; 660–690 V 15 kW
Rated Operational Power AC-3 (Pe)3-phase: 220–240 V 5.5 kW; 380–440 V 11 kW; 500 V 11 kW; 660–690 V 11 kW. 1-phase: 110–120 V 2.2 kW; 220–240 V 4 kW; 380–440 V 5.5 kW
Rated Operational Power AC-4 (Pe)3-phase: 220–240 V 2.7 kW; 380–440 V 5.5 kW; 500 V 5.5 kW; 660–690 V 5.5 kW. 1-phase: 110–120 V 0.75 kW; 220–240 V 1.5 kW; 380–440 V 3 kW
Rated Operational Power AC-23A (Pe)3-phase: 220–240 V 7.5 kW; 380–440 V 15 kW; 500 V 15 kW; 660–690 V 15 kW. 1-phase: 110–120 V 2.2 kW; 220–240 V 4 kW; 380–440 V 7.5 kW
Maximum Fuse CurrentgG 50 A
Rated Short-Time Withstand Current (Icw)350 A (1 s)
Breaking Capacity220–240 V: 280 A; 380–440 V: 250 A; 660–690 V: 150 A
Power Loss per Pole1.3 W
Solid Conductor Cable Cross-Section1–6 mm2
Stranded Conductor Cable Cross-Section2x6 mm2
Flexible Conductor Cross-Section1.5–6 mm2
Conductor Cross-Section with Ferrule1–4 mm2
Cable section (AWG/MCM)AWG 10 (flexible); AWG 8 (solid or stranded)
Conductor MaterialCopper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered)
Tightening Torque1.3 Nm (12 lb-in)
Recommended Screw DriverPozidriv/Phillips PH2; slotted 1 x 5.5 mm (DIN 5264)
Contact TypeRigid bridging link

Shipping & assurance

For made-to-order products, the procurement and carrier hand-over time is shared with the quotation.

In rare cases, all or part of an order may be unavailable due to stock or procurement updates. In this case, the customer is informed and the relevant product is cancelled and refunded. A product being open for sale does not guarantee that it is in physical store stock.

Delivery and returns