Kraus & Naimer C32 A442 Two-Speed (Dahlander) Reversing Cam Switch, 3-Pole, 50 A, 64 x 64 mm Front Plate

Kraus & Naimer C32 A442 Two-Speed (Dahlander) Reversing Cam Switch, 3-Pole, 50 A, 64 x 64 mm Front Plate

Kraus & Naimer C32 A442 is a 3-pole, 50 A reversing two-speed (Dahlander) cam switch with 2-1-0-1-2 positions for single-winding motors. Technical values: C32 type, size class S1, 64 x 64 mm front plate; thermal current Ith 50 A (55 °C), enclosed thermal current Ithe 50 A; rated insulation voltage Ui 690 V, rated impulse withstand voltage Uimp 6 kV; AC-21A 40 A, AC-22A 40 A, AC-15 380–440 V 7 A; three-phase motor rating at 380–440 V: AC-3 15 kW, AC-23A 22 kW; maximum gG 63 A fuse, Icw 800 A (1 s); conductor cross-section: solid 1–10 mm², flexible 1.5–6 mm²; tightening torque 2.2 Nm; 3 poles, 6 levels, positions 2-1-0-1-2, switching angle 45°. Values are given in accordance with IEC 60947-3 and EN 60947-3. It is used with single-winding (Dahlander-type) two-speed motors where speed selection is needed in both directions of rotation; the centre 0 position stops the motor.

SeriesC32
Size TypeS1
Function CodeA442
Switch FunctionÇift Devirli Yön Değiştirmeli (2-1-0-1-2)
Switch Positions2-1-0-1-2
Number of Positions5
Switching Angle45° °
Number of Poles3P
Number of Levels6
Front Plate CodeF105
Front Plate Size (A x B)64 x 64 mm
Rated Current50 A
Conventional Free Air Thermal Current (Ith)50 A
Ambient temperature for rated current55 °C (24 hours, tepe 60 °C)
Conventional Enclosed Thermal Current (Ithe)50 A
Rated Insulation Voltage (Ui)690 V (AC 50/60 Hz)
Rated Impulse Withstand Voltage (Uimp)6 kV
Overvoltage categoryIII
Pollution Degree3
Rated Operational Current AC-15 (Ie)220–240 V: 16 A; 380–440 V: 7 A
Rated Operational Current AC-20A (Ie)690 V: 50 A
Rated Operational Current AC-21A (Ie)20–690 V: 40 A
Rated Operational Current AC-22A (Ie)220–500 V: 40 A; 660–690 V: 40 A
Rated Operational Power AC-2 (Pe)3-phase: 220–240 V 10 kW; 380–440 V 18.5 kW; 500 V 22 kW; 660–690 V 22 kW
Rated Operational Power AC-3 (Pe)3-phase: 220–240 V 7.5 kW; 380–440 V 15 kW; 500 V 15 kW; 660–690 V 15 kW. 1-phase: 110–120 V 2.5 kW; 220–240 V 5.5 kW; 380–440 V 7.5 kW
Rated Operational Power AC-4 (Pe)3-phase: 220–240 V 3.7 kW; 380–440 V 6 kW; 500 V 6 kW; 660–690 V 6 kW. 1-phase: 110–120 V 1.1 kW; 220–240 V 2.2 kW; 380–440 V 3.7 kW
Rated Operational Power AC-23A (Pe)3-phase: 220–240 V 11 kW; 380–440 V 22 kW; 500 V 30 kW; 660–690 V 22 kW. 1-phase: 110–120 V 2.5 kW; 220–240 V 5.5 kW; 380–440 V 11 kW
Maximum Fuse CurrentgG 63 A
Rated Short-Time Withstand Current (Icw)800 A (1 s)
Breaking Capacity220–240 V: 380 A; 380–440 V: 360 A; 660–690 V: 270 A
Power Loss per Pole1.3 W
Solid Conductor Cable Cross-Section1–10 mm2
Stranded Conductor Cable Cross-Section2x10 mm2
Flexible Conductor Cross-Section1.5–6 mm2
Conductor Cross-Section with Ferrule1–6 mm2
Cable section (AWG/MCM)AWG 8
Conductor MaterialCopper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered)
Tightening Torque2.2 Nm (19.5 lb-in)
Recommended Screw DriverPozidriv/Phillips PH2; slotted 1.2 x 8 mm (DIN 5264)
Contact TypeRigid bridging link