Kraus & Naimer CA20 A442 Two-Speed (Dahlander) Reversing Cam Switch, 3-Pole, 25 A, 48 x 48 mm Front Plate

Kraus & Naimer CA20 A442 Two-Speed (Dahlander) Reversing Cam Switch, 3-Pole, 25 A, 48 x 48 mm Front Plate

Kraus & Naimer CA20 A442 is a 3-pole, 25 A reversing two-speed (Dahlander) cam switch with 2-1-0-1-2 positions for single-winding motors. Technical values: CA20 type, size class S0, 48 x 48 mm front plate; thermal current Ith 25 A (55 °C), enclosed thermal current Ithe 25 A; rated insulation voltage Ui 690 V, rated impulse withstand voltage Uimp 6 kV; AC-21A 25 A, AC-22A 25 A, AC-15 380–440 V 5 A; three-phase motor rating at 380–440 V: AC-3 7.5 kW, AC-23A 11 kW; maximum gG 35 A fuse, Icw 280 A (1 s); conductor cross-section: solid 0.75–4 mm², flexible 1.5–4 mm²; tightening torque 1 Nm; 3 poles, 6 levels, positions 2-1-0-1-2, switching angle 45°. Values are given in accordance with IEC 60947-3 and EN 60947-3. It is used with single-winding (Dahlander-type) two-speed motors where speed selection is needed in both directions of rotation; the centre 0 position stops the motor.

SeriesCA20
Size TypeS0
Function CodeA442
Switch FunctionÇift Devirli Yön Değiştirmeli (2-1-0-1-2)
Switch Positions2-1-0-1-2
Number of Positions5
Switching Angle45° °
Number of Poles3P
Number of Levels6
Front Plate CodeF105
Front Plate Size (A x B)48 x 48 mm
Rated Current25 A
Conventional Free Air Thermal Current (Ith)25 A
Ambient temperature for rated current55 °C (24 hours, tepe 60 °C)
Conventional Enclosed Thermal Current (Ithe)25 A
Rated Insulation Voltage (Ui)690 V (AC 50/60 Hz)
Rated Impulse Withstand Voltage (Uimp)6 kV
Overvoltage categoryIII
Pollution Degree3
Rated Operational Current AC-15 (Ie)220–240 V: 8 A; 380–440 V: 5 A
Rated Operational Current AC-20A (Ie)690 V: 25 A
Rated Operational Current AC-21A (Ie)20–690 V: 25 A
Rated Operational Current AC-22A (Ie)220–500 V: 25 A; 660–690 V: 25 A
Rated Operational Power AC-2 (Pe)3-phase: 220–240 V 5.5 kW; 380–440 V 11 kW; 500 V 15 kW; 660–690 V 13 kW
Rated Operational Power AC-3 (Pe)3-phase: 220–240 V 4 kW; 380–440 V 7.5 kW; 500 V 7.5 kW; 660–690 V 7.5 kW. 1-phase: 110–120 V 1.5 kW; 220–240 V 3 kW; 380–440 V 3.7 kW
Rated Operational Power AC-4 (Pe)3-phase: 220–240 V 1.5 kW; 380–440 V 3 kW; 500 V 3 kW; 660–690 V 3 kW. 1-phase: 110–120 V 0.45 kW; 220–240 V 1.1 kW; 380–440 V 2.2 kW
Rated Operational Power AC-23A (Pe)3-phase: 220–240 V 5.5 kW; 380–440 V 11 kW; 500 V 11 kW; 660–690 V 11 kW. 1-phase: 110–120 V 1.5 kW; 220–240 V 3 kW; 380–440 V 5.5 kW
Maximum Fuse CurrentgG 35 A
Rated Short-Time Withstand Current (Icw)280 A (1 s)
Breaking Capacity220–240 V: 200 A; 380–440 V: 200 A; 660–690 V: 125 A
Power Loss per Pole0.9 W
Solid Conductor Cable Cross-Section0.75–4 mm2
Stranded Conductor Cable Cross-Section2x4 mm2
Flexible Conductor Cross-Section1.5–4 mm2
Conductor Cross-Section with Ferrule1–2.5 mm2
Cable section (AWG/MCM)AWG 12 (flexible); AWG 10 (solid or stranded)
Conductor MaterialCopper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered)
Tightening Torque1 Nm (9 lb-in)
Recommended Screw DriverPozidriv/Phillips PH1; slotted 0.8 x 5.5 mm (DIN 5264)