Kraus & Naimer CA10 A425/TRA101 Split-Phase Motor Start Cam Switch, 20 A, in Enclosure (KE01)
- Brand: Kraus & Naimer
- SKU: CA10 A425/TRA101
- MPN: CA10 A425/TRA101
- Model: 20 A
- Price: 2034.00 TRY + VAT · incl. VAT 2440.80 TRY
- Availability: Made to order
- Single-Phase Motor Starting Switches
- Selection guide: Cam Switches Selection Guide
Kraus & Naimer CA10 A425/TRA101 is a 20 A split-phase start cam switch for single-phase motors with an auxiliary start winding. The switch has positions 0-1-START, a switching angle of 90° + 30° and 2 levels. It is supplied as an enclosed (TRA) version in a KE01 enclosure (IP65) with an I handle. Front plate code F119; size type S0. Rated insulation voltage is 690 V (AC 50/60 Hz) and rated impulse withstand voltage is 6 kV (switch), 4 kV (switch disconnector). AC-21A rated operational current is 20 A over 20–690 V; single-phase AC-3 rated power (220–240 V) is 2.2 kW; AC-23A rated power (220–240 V) is 2.5 kW. Maximum fuse rating gG 25 A; rated short-time withstand current 140 A (1 s); power loss per pole 0.9 W. The terminals accept stranded conductors up to 2 x 2.5 mm²; tightening torque is 0.6 Nm (5 lb-in); operating temperature is -25…+60 °C. It is used to control the starting and running of single-phase motors with an auxiliary (start) winding.
| Series | CA10 |
|---|---|
| Size Type | S0 |
| Function Code | A425 |
| Switch Function | Tek Fazlı Yardımcı Sargılı Motor (0-1-START) |
| Switch Positions | 0-1-START |
| Number of Positions | 3 |
| Switching Angle | 90° + 30° ° |
| Number of Levels | 2 |
| Front Plate Code | F119 |
| Mounting Type | Kutulu |
| IP Rating | IP65 |
| Handle Type | I kolu |
| Box Type | KE01 |
| Rated Current | 20 A |
| Conventional Free Air Thermal Current (Ith) | 20 A |
| Ambient temperature for rated current | 55 °C (24 hours, tepe 60 °C) |
| Conventional Enclosed Thermal Current (Ithe) | 20 A |
| Rated Insulation Voltage (Ui) | 690 V (AC 50/60 Hz) |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV (circuit breaker); 4 kV (switch-disconnector) |
| Overvoltage category | III |
| Pollution Degree | 3 |
| Rated Operational Current AC-15 (Ie) | 220–240 V: 6 A; 380–440 V: 4 A |
| Rated Operational Current AC-20A (Ie) | 690 V: 20 A |
| Rated Operational Current AC-21A (Ie) | 20–690 V: 20 A |
| Rated Operational Current AC-22A (Ie) | 220–500 V: 20 A; 660–690 V: 20 A |
| Rated Operational Power AC-2 (Pe) | 3-phase: 220–240 V 4 kW; 380–440 V 7.5 kW; 500 V 10 kW; 660–690 V 10 kW |
| Rated Operational Power AC-3 (Pe) | 3-phase: 220–240 V 3 kW; 380–440 V 5.5 kW; 500 V 5.5 kW; 660–690 V 5.5 kW. 1-phase: 110–120 V 0.6 kW; 220–240 V 2.2 kW; 380–440 V 3 kW |
| Rated Operational Power AC-4 (Pe) | 3-phase: 220–240 V 0.55 kW; 380–440 V 1.5 kW; 500 V 1.5 kW; 660–690 V 1.5 kW. 1-phase: 110–120 V 0.3 kW; 220–240 V 0.75 kW; 380–440 V 1.5 kW |
| Rated Operational Power AC-23A (Pe) | 3-phase: 220–240 V 3.7 kW; 380–440 V 7.5 kW; 500 V 7.5 kW; 660–690 V 7.5 kW. 1-phase: 110–120 V 0.75 kW; 220–240 V 2.5 kW; 380–440 V 3.7 kW |
| Maximum Fuse Current | gG 25 A |
| Rated Short-Time Withstand Current (Icw) | 140 A (1 s) |
| Breaking Capacity | 220–240 V: 150 A; 380–440 V: 150 A; 660–690 V: 80 A |
| Power Loss per Pole | 0.9 W |
| Solid Conductor Cable Cross-Section | 0.5–2.5 mm2 |
| Stranded Conductor Cable Cross-Section | 2x2.5 mm2 |
| Flexible Conductor Cross-Section | 0.75–2.5 mm2 |
| Conductor Cross-Section with Ferrule | 0.5–2.5 mm2 |
| Cable section (AWG/MCM) | AWG 14 (flexible); AWG 12 (solid or stranded) |
| Conductor Material | Copper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered) |
| Tightening Torque | 0.6 Nm (5 lb-in) |