Kraus & Naimer CA20B A342-E+S1V840G/D6 On-Off Cam Switch, 6-Pole, 25 A, 64 x 64 mm Front Plate

Kraus & Naimer CA20B A342-E+S1V840G/D6 On-Off Cam Switch, 6-Pole, 25 A, 64 x 64 mm Front Plate

Kraus & Naimer CA20B A342-E+S1V840G/D6 is a 25 A (Ith) CA20B series cam switch; function: 6-pole on-off (0-1) switch (lift switch). Mounting: E mounting (four-hole panel), 64 x 64 mm front plate; the S1 V840G extra is a padlock device for 3 padlocks (7–8 mm shackle). Switching function: positions 0-1; switching angle 60°; 3 contact stages. Ratings: rated insulation voltage Ui 690 V, impulse withstand voltage Uimp 6 kV, AC-21A 25 A, three-phase motor rating at 380–440 V: AC-3 7.5 kW, AC-23A 11 kW, breaking capacity 200 / 200 / 125 A (220–240 / 380–440 / 660–690 V), maximum fuse 35 A gG, short-time withstand current 280 A (1 s). Connection: flexible conductors 1.5–4 mm², solid or stranded conductors 0.75–4 mm², terminal tightening torque 1 Nm. It is used to switch the supply circuit of a lift on and off (0-1).

Size TypeS1
Number of Poles6P
SeriesCA20B
Function CodeA342
Switch FunctionAç-Kapa (0-1)
Switch Positions0-1
Number of Positions2
Switching Angle60° °
Number of Levels3
Front Plate CodeF070
Front Plate Size (A x B)64 x 64 mm
Rated Current25 A
Conventional Free Air Thermal Current (Ith)25 A
Ambient temperature for rated current55 °C (24 hours, tepe 60 °C)
Conventional Enclosed Thermal Current (Ithe)25 A
Rated Insulation Voltage (Ui)690 V (AC 50/60 Hz and DC)
Rated Impulse Withstand Voltage (Uimp)6 kV
Overvoltage categoryIII
Pollution Degree3
Rated Operational Current AC-15 (Ie)220–240 V: 8 A; 380–440 V: 5 A
Rated Operational Current AC-20A (Ie)690 V: 25 A
Rated Operational Current AC-21A (Ie)20–690 V: 25 A
Rated Operational Current AC-22A (Ie)220–500 V: 25 A; 660–690 V: 25 A
Rated Operational Power AC-2 (Pe)3-phase: 220–240 V 5.5 kW; 380–440 V 11 kW; 500 V 15 kW; 660–690 V 13 kW
Rated Operational Power AC-3 (Pe)3-phase: 220–240 V 4 kW; 380–440 V 7.5 kW; 500 V 7.5 kW; 660–690 V 7.5 kW. 1-phase: 110–120 V 1.5 kW; 220–240 V 3 kW; 380–440 V 3.7 kW
Rated Operational Power AC-4 (Pe)3-phase: 220–240 V 1.5 kW; 380–440 V 3 kW; 500 V 3 kW; 660–690 V 3 kW. 1-phase: 110–120 V 0.45 kW; 220–240 V 1.1 kW; 380–440 V 2.2 kW
Rated Operational Power AC-23A (Pe)3-phase: 220–240 V 5.5 kW; 380–440 V 11 kW; 500 V 11 kW; 660–690 V 11 kW. 1-phase: 110–120 V 1.5 kW; 220–240 V 3 kW; 380–440 V 5.5 kW
Maximum Fuse CurrentgG 35 A
Rated Short-Time Withstand Current (Icw)280 A (1 s)
Breaking Capacity220–240 V: 200 A; 380–440 V: 200 A; 660–690 V: 125 A
Power Loss per Pole0.9 W
Solid Conductor Cable Cross-Section0.75–4 mm2
Stranded Conductor Cable Cross-Section2x4 mm2
Flexible Conductor Cross-Section1.5–4 mm2
Conductor Cross-Section with Ferrule1–2.5 mm2
Cable section (AWG/MCM)AWG 12 (flexible); AWG 10 (solid or stranded)
Conductor MaterialCopper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered)
Tightening Torque1 Nm (9 lb-in)
Recommended Screw DriverPozidriv/Phillips PH1; slotted 0.8 x 5.5 mm (DIN 5264)
Contact TypeRigid bridging link