Kraus & Naimer CA4 A004-600 FS2 Voltmeter Selector Switch, 10 A, 30 x 30 mm Front Plate

Kraus & Naimer CA4 A004-600 FS2 Voltmeter Selector Switch, 10 A, 30 x 30 mm Front Plate

Kraus & Naimer CA4 A004-600 FS2 is a 10 A (Ith) CA4 series cam switch; function: voltmeter selector switch with OFF for 3-phase 3-wire systems (OFF plus 3 phase-to-phase positions, 4 positions in total). Mounting: single-hole FS2 mounting (16/22 mm), 30 x 30 mm square front plate, IP66/67/69k. Switching function: positions OFF + 3 phase-to-phase (4 positions); switching angle 45°; 2 contact stages. Ratings: rated insulation voltage Ui 440 V, impulse withstand voltage Uimp 4 kV, AC-21A 10 A, maximum fuse 10 A gG, short-time withstand current 60 A (1 s). Connection: flexible conductors 0.75–1.5 mm², solid or stranded conductors 0.5–1.5 mm², terminal tightening torque 0.4 Nm. It is used to read the three phase-to-phase voltages in turn with a single voltmeter.

SeriesCA4
Size TypeS00
Function CodeA004
Switch FunctionVoltmetre Komütatörü (0, L1-L2, L2-L3, L3-L1)
Switch Positions0, L1-L2, L2-L3, L3-L1
Number of Positions4
Switching Angle45° °
Number of Levels2
Front Plate Size (A x B)30 x 30 mm
Rated Current10 A
Conventional Free Air Thermal Current (Ith)10 A
Ambient temperature for rated current55 °C (24 hours, tepe 60 °C)
Conventional Enclosed Thermal Current (Ithe)10 A
Rated Insulation Voltage (Ui)440 V (AC 50/60 Hz)
Rated Impulse Withstand Voltage (Uimp)4 kV
Overvoltage categoryIII
Pollution Degree3
Rated Operational Current AC-15 (Ie)220–240 V: 2.5 A; 380–440 V: 1.5 A
Rated Operational Current AC-20A (Ie)440 V: 10 A
Rated Operational Current AC-21A (Ie)440 V: 10 A
Rated Operational Current AC-22A (Ie)220–440 V: 10 A
Rated Operational Power AC-2 (Pe)3-phase: 220–240 V 2.5 kW; 380–440 V 4.5 kW
Rated Operational Power AC-3 (Pe)3-phase: 220–240 V 1.5 kW; 380–440 V 2.2 kW. 1-phase: 110–120 V 0.3 kW; 220–240 V 0.55 kW; 380–440 V 0.75 kW
Rated Operational Power AC-4 (Pe)3-phase: 220–240 V 0.37 kW; 380–440 V 0.55 kW. 1-phase: 110–120 V 0.15 kW; 220–240 V 0.25 kW; 380–440 V 0.5 kW
Rated Operational Power AC-23A (Pe)3-phase: 220–240 V 1.8 kW; 380–440 V 3 kW. 1-phase: 110–120 V 0.37 kW; 220–240 V 0.75 kW; 380–440 V 1.1 kW
Maximum Fuse CurrentgG 10 A
Rated Short-Time Withstand Current (Icw)60 A (1 s)
Breaking Capacity220–240 V: 50 A; 380–440 V: 50 A
Power Loss per Pole0.4 W
Solid Conductor Cable Cross-Section0.5–1.5 mm2
Stranded Conductor Cable Cross-Section2x1.5 mm2
Flexible Conductor Cross-Section0.75–1.5 mm2
Conductor Cross-Section with Ferrule0.5–1 mm2
Cable section (AWG/MCM)AWG 16 (flexible); AWG 14 (solid or stranded)
Conductor MaterialCopper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered)
Tightening Torque0.4 Nm (3.5 lb-in)
Recommended Screw DriverPozidriv/Phillips PH1; slotted 0.6 x 3.5 mm (DIN 5264)
Contact TypeRigid bridging link
Contact MaterialSilver
Connection TypeScrew terminal