Kraus & Naimer CA4 A048-600 FS2 Ammeter Selector Switch, 1-Pole, 10 A, 30 x 30 mm Front Plate
- Brand: Kraus & Naimer
- SKU: CA4 A048-600 FS2
- MPN: CA4 A048-600 FS2
- Price: 3692.94 TRY + VAT · incl. VAT 4431.53 TRY
- Availability: Made to order
- Selector Step Switches
- Kraus & Naimer Selector Step Switches
- Selection guide: What Is a Selector Step Switch? Uses and Selection Criteria
Kraus & Naimer CA4 A048-600 FS2 is a 10 A (Ith) CA4 series cam switch; function: ammeter selector switch with OFF (single pole, for 3 current transformers; OFF plus 3 transformer positions). Mounting: single-hole FS2 mounting (16/22 mm), 30 x 30 mm square front plate, IP66/67/69k. Switching function: positions OFF + 3 current transformer positions (4 positions); switching angle 90°; 3 contact stages. Ratings: rated insulation voltage Ui 440 V, impulse withstand voltage Uimp 4 kV, AC-21A 10 A, maximum fuse 10 A gG, short-time withstand current 60 A (1 s). Connection: flexible conductors 0.75–1.5 mm², solid or stranded conductors 0.5–1.5 mm², terminal tightening torque 0.4 Nm. It is used to read the currents of three current transformers in turn with a single ammeter.
| Number of Poles | 1P |
|---|---|
| Series | CA4 |
| Size Type | S00 |
| Function Code | A048 |
| Switch Function | Ampermetre Komütatörü (0-1-2-3) |
| Switch Positions | 0-1-2-3 |
| Number of Positions | 4 |
| Switching Angle | 90° ° |
| Number of Levels | 3 |
| Front Plate Size (A x B) | 30 x 30 mm |
| Rated Current | 10 A |
| Conventional Free Air Thermal Current (Ith) | 10 A |
| Ambient temperature for rated current | 55 °C (24 hours, tepe 60 °C) |
| Conventional Enclosed Thermal Current (Ithe) | 10 A |
| Rated Insulation Voltage (Ui) | 440 V (AC 50/60 Hz) |
| Rated Impulse Withstand Voltage (Uimp) | 4 kV |
| Overvoltage category | III |
| Pollution Degree | 3 |
| Rated Operational Current AC-15 (Ie) | 220–240 V: 2.5 A; 380–440 V: 1.5 A |
| Rated Operational Current AC-20A (Ie) | 440 V: 10 A |
| Rated Operational Current AC-21A (Ie) | 440 V: 10 A |
| Rated Operational Current AC-22A (Ie) | 220–440 V: 10 A |
| Rated Operational Power AC-2 (Pe) | 3-phase: 220–240 V 2.5 kW; 380–440 V 4.5 kW |
| Rated Operational Power AC-3 (Pe) | 3-phase: 220–240 V 1.5 kW; 380–440 V 2.2 kW. 1-phase: 110–120 V 0.3 kW; 220–240 V 0.55 kW; 380–440 V 0.75 kW |
| Rated Operational Power AC-4 (Pe) | 3-phase: 220–240 V 0.37 kW; 380–440 V 0.55 kW. 1-phase: 110–120 V 0.15 kW; 220–240 V 0.25 kW; 380–440 V 0.5 kW |
| Rated Operational Power AC-23A (Pe) | 3-phase: 220–240 V 1.8 kW; 380–440 V 3 kW. 1-phase: 110–120 V 0.37 kW; 220–240 V 0.75 kW; 380–440 V 1.1 kW |
| Maximum Fuse Current | gG 10 A |
| Rated Short-Time Withstand Current (Icw) | 60 A (1 s) |
| Breaking Capacity | 220–240 V: 50 A; 380–440 V: 50 A |
| Power Loss per Pole | 0.4 W |
| Solid Conductor Cable Cross-Section | 0.5–1.5 mm2 |
| Stranded Conductor Cable Cross-Section | 2x1.5 mm2 |
| Flexible Conductor Cross-Section | 0.75–1.5 mm2 |
| Conductor Cross-Section with Ferrule | 0.5–1 mm2 |
| Cable section (AWG/MCM) | AWG 16 (flexible); AWG 14 (solid or stranded) |
| Conductor Material | Copper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered) |
| Tightening Torque | 0.4 Nm (3.5 lb-in) |
| Recommended Screw Driver | Pozidriv/Phillips PH1; slotted 0.6 x 3.5 mm (DIN 5264) |
| Contact Type | Rigid bridging link |
| Contact Material | Silver |