Kraus & Naimer CG8 A004 DÖKME Voltmeter Selector Switch, 20 A, 48 x 48 mm Front Plate, Bulk Version
- Brand: Kraus & Naimer
- SKU: CG8 A004 DÖKME
- MPN: CG8 A004 DÖKME
- Price: 1454.00 TRY + VAT · incl. VAT 1744.80 TRY
- Availability: Made to order
- Selector Step Switches
- Kraus & Naimer Selector Step Switches
- Selection guide: What Is a Selector Step Switch? Uses and Selection Criteria
Kraus & Naimer CG8 A004 DÖKME is a 20 A (Ith) CG8 series cam switch; function: voltmeter selector switch with OFF for 3-phase 3-wire systems (OFF plus 3 phase-to-phase positions, 4 positions in total). Front plate 48 x 48 mm. This is the bulk version; type and function are the same as CG8 A004. Switching function: positions OFF + 3 phase-to-phase (4 positions); switching angle 45°; 2 contact stages. Ratings: rated insulation voltage Ui 690 V, impulse withstand voltage Uimp 6 kV (switch), AC-21A 20 A, maximum fuse 25 A gG, short-time withstand current 140 A (1 s). Connection: flexible conductors 0.75–2.5 mm², solid or stranded conductors 0.5–2.5 mm², terminal tightening torque 0.6 Nm. It is used to read the three phase-to-phase voltages in turn with a single voltmeter.
| Series | CG8 |
|---|---|
| Size Type | S0 |
| Function Code | A004 |
| Switch Function | Voltmetre Komütatörü (0, L1-L2, L2-L3, L3-L1) |
| Switch Positions | 0, L1-L2, L2-L3, L3-L1 |
| Number of Positions | 4 |
| Switching Angle | 45° ° |
| Number of Levels | 2 |
| Front Plate Code | F775 |
| Front Plate Size (A x B) | 48 x 48 mm |
| Rated Current | 20 A |
| Conventional Free Air Thermal Current (Ith) | 20 A |
| Ambient temperature for rated current | 55 °C (24 hours, tepe 60 °C) |
| Conventional Enclosed Thermal Current (Ithe) | 20 A |
| Rated Insulation Voltage (Ui) | 690 V (AC 50/60 Hz) |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV (circuit breaker) |
| Overvoltage category | III |
| Pollution Degree | 3 |
| Rated Operational Current AC-15 (Ie) | 110 V: 6 A; 220–240 V: 6 A; 380–440 V: 4 A |
| Rated Operational Current AC-20A (Ie) | 690 V: 20 A |
| Rated Operational Current AC-21A (Ie) | 20–690 V: 20 A |
| Rated Operational Current AC-22A (Ie) | 220–440 V: 20 A; 500 V: 20 A; 660–690 V: 16 A |
| Rated Operational Power AC-2 (Pe) | 3-phase: 220–240 V 4 kW; 380–440 V 7.5 kW; 500 V 10 kW; 660–690 V 10 kW |
| Rated Operational Power AC-3 (Pe) | 3-phase: 220–240 V 3 kW; 380–440 V 5.5 kW; 500 V 5.5 kW; 660–690 V 5.5 kW. 1-phase: 110–120 V 0.6 kW; 220–240 V 2.2 kW; 380–440 V 3 kW |
| Rated Operational Power AC-4 (Pe) | 3-phase: 220–240 V 0.55 kW; 380–440 V 1.5 kW; 500 V 1.5 kW; 660–690 V 1.5 kW. 1-phase: 110–120 V 0.3 kW; 220–240 V 0.75 kW; 380–440 V 1.5 kW |
| Rated Operational Power AC-23A (Pe) | 3-phase: 220–240 V 3.7 kW; 380–440 V 7.5 kW; 500 V 7.5 kW; 660–690 V 7.5 kW. 1-phase: 110–120 V 0.75 kW; 220–240 V 2.5 kW; 380–440 V 3.7 kW |
| Maximum Fuse Current | gG 25 A |
| Rated Short-Time Withstand Current (Icw) | 140 A (1 s) |
| Breaking Capacity | 220–240 V: 150 A; 380–440 V: 150 A; 660–690 V: 80 A |
| Power Loss per Pole | 0.8 W |
| Solid Conductor Cable Cross-Section | 0.5–2.5 mm2 |
| Stranded Conductor Cable Cross-Section | 2x2.5 mm2 |
| Flexible Conductor Cross-Section | 0.75–2.5 mm2 |
| Conductor Cross-Section with Ferrule | 0.5–2.5 mm2 |
| Cable section (AWG/MCM) | AWG 14 (flexible); AWG 12 (solid or stranded) |
| Conductor Material | Copper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered) |
| Tightening Torque | 0.6 Nm (5 lb-in) |
| Recommended Screw Driver | Pozidriv/Phillips PH1; slotted 0.8 x 4 mm (DIN 5264) |
| Contact Type | Rigid bridging link |
| Contact Material | Silver |
Shipping & assurance
For made-to-order products, the procurement and carrier hand-over time is shared with the quotation.
In rare cases, all or part of an order may be unavailable due to stock or procurement updates. In this case, the customer is informed and the relevant product is cancelled and refunded. A product being open for sale does not guarantee that it is in physical store stock.