Kraus & Naimer CG8 A007 is a 20 A (Ith) CG8 series cam switch; function: voltmeter selector switch with OFF for 3-phase 3-wire systems (3 phase-to-phase, OFF and 3 phase-to-neutral positions, 7 positions in total). Front plate 48 x 48 mm. Switching function: positions 3 phase-to-phase + OFF + 3 phase-to-neutral (7 positions); switching angle 45°; 3 contact stages. Ratings: rated insulation voltage Ui 690 V, impulse withstand voltage Uimp 6 kV (switch), AC-21A 20 A, maximum fuse 25 A gG, short-time withstand current 140 A (1 s). Connection: flexible conductors 0.75–2.5 mm², solid or stranded conductors 0.5–2.5 mm², terminal tightening torque 0.6 Nm. It is used to select and read phase-to-phase and phase-to-neutral voltages with a single voltmeter.

SeriesCG8
Size TypeS0
Function CodeA007
Switch FunctionVoltmetre Komütatörü (L3-L1, L2-L3, L1-L2, 0, L1-N, L2-N, L3-N)
Switch PositionsL3-L1, L2-L3, L1-L2, 0, L1-N, L2-N, L3-N
Number of Positions7
Switching Angle45° °
Number of Levels3
Front Plate CodeF782
Front Plate Size (A x B)48 x 48 mm
Rated Current20 A
Conventional Free Air Thermal Current (Ith)20 A
Ambient temperature for rated current55 °C (24 hours, tepe 60 °C)
Conventional Enclosed Thermal Current (Ithe)20 A
Rated Insulation Voltage (Ui)690 V (AC 50/60 Hz)
Rated Impulse Withstand Voltage (Uimp)6 kV (circuit breaker)
Overvoltage categoryIII
Pollution Degree3
Rated Operational Current AC-15 (Ie)110 V: 6 A; 220–240 V: 6 A; 380–440 V: 4 A
Rated Operational Current AC-20A (Ie)690 V: 20 A
Rated Operational Current AC-21A (Ie)20–690 V: 20 A
Rated Operational Current AC-22A (Ie)220–440 V: 20 A; 500 V: 20 A; 660–690 V: 16 A
Rated Operational Power AC-2 (Pe)3-phase: 220–240 V 4 kW; 380–440 V 7.5 kW; 500 V 10 kW; 660–690 V 10 kW
Rated Operational Power AC-3 (Pe)3-phase: 220–240 V 3 kW; 380–440 V 5.5 kW; 500 V 5.5 kW; 660–690 V 5.5 kW. 1-phase: 110–120 V 0.6 kW; 220–240 V 2.2 kW; 380–440 V 3 kW
Rated Operational Power AC-4 (Pe)3-phase: 220–240 V 0.55 kW; 380–440 V 1.5 kW; 500 V 1.5 kW; 660–690 V 1.5 kW. 1-phase: 110–120 V 0.3 kW; 220–240 V 0.75 kW; 380–440 V 1.5 kW
Rated Operational Power AC-23A (Pe)3-phase: 220–240 V 3.7 kW; 380–440 V 7.5 kW; 500 V 7.5 kW; 660–690 V 7.5 kW. 1-phase: 110–120 V 0.75 kW; 220–240 V 2.5 kW; 380–440 V 3.7 kW
Maximum Fuse CurrentgG 25 A
Rated Short-Time Withstand Current (Icw)140 A (1 s)
Breaking Capacity220–240 V: 150 A; 380–440 V: 150 A; 660–690 V: 80 A
Power Loss per Pole0.8 W
Solid Conductor Cable Cross-Section0.5–2.5 mm2
Stranded Conductor Cable Cross-Section2x2.5 mm2
Flexible Conductor Cross-Section0.75–2.5 mm2
Conductor Cross-Section with Ferrule0.5–2.5 mm2
Cable section (AWG/MCM)AWG 14 (flexible); AWG 12 (solid or stranded)
Conductor MaterialCopper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered)
Tightening Torque0.6 Nm (5 lb-in)
Recommended Screw DriverPozidriv/Phillips PH1; slotted 0.8 x 4 mm (DIN 5264)
Contact TypeRigid bridging link
Contact MaterialSilver