Kraus & Naimer KG125 T203/09 VE Emergency Stop Main Switch, 3-Pole, 125 A, 88 x 88 mm Front Plate

Kraus & Naimer KG125 T203/09 VE Emergency Stop Main Switch, 3-Pole, 125 A, 88 x 88 mm Front Plate

Kraus & Naimer KG125 T203/09 VE is a 125 A (Ith), 3-pole emergency stop main switch (red handle, yellow front plate); base mounting with door clutch, 88 x 88 mm escutcheon plate, IP66/67. Ratings: rated insulation voltage Ui 1000 V, impulse withstand voltage Uimp 8 kV, AC-21A 125 A, three-phase motor rating at 380–440 V: AC-3 37 kW, AC-23A 45 kW, breaking capacity 800 / 750 / 340 A (220–240 / 380–440 / 660–690 V), maximum fuse 125 A gG, short-time withstand current 2500 A (1 s). Connection: flexible conductors 16–70 mm², solid or stranded conductors 6–95 mm², terminal tightening torque 14 Nm. Versions with door clutch are also supplied with a padlock device. A padlockable handle and a protective cover for the incoming terminals are standard equipment. The KG and C316 series switches exceed the requirements of IEC 60947-3 / EN 60947-3 (VDE 0660 part 107), IEC/EN 60204 and VDE 0113 and are used as switch disconnectors, main switches and maintenance switches.

Number of Poles3P
Rated Current125 A
Mounting TypeVE taban montajı, kapı kavramalı
IP RatingIP66/67
SeriesKG125
Size TypeS2
Function CodeT203
Switch FunctionAcil Durdurma Fonksiyonlu Ana Şalter (0-1)
Switch Positions0-1
Number of Positions2
Front Plate Size (A x B)88 x 88 mm
Handle ColorRed (sarı ön plaka)
Conventional Free Air Thermal Current (Ith)125 A
Ambient temperature for rated current50 °C (24 hours, tepe 55 °C)
Conventional Enclosed Thermal Current (Ithe)125 A
Rated Insulation Voltage (Ui)1000 V (AC 50/60 Hz)
Rated Impulse Withstand Voltage (Uimp)8 kV
Overvoltage categoryIII
Pollution Degree3
Rated Operational Current AC-20A (Ie)1000 V: 125 A
Rated Operational Current AC-21A (Ie)20–690 V: 125 A
Rated Operational Current AC-22A (Ie)220–500 V: 125 A; 660–690 V: 100 A
Rated Operational Power AC-3 (Pe)3-phase: 220–240 V 22 kW; 380–440 V 37 kW; 500 V 45 kW; 660–690 V 30 kW
Rated Operational Power AC-23A (Pe)3-phase: 220–240 V 30 kW; 380–440 V 45 kW; 500 V 55 kW; 660–690 V 37 kW
Maximum Fuse CurrentgG 125 A
Rated Short-Time Withstand Current (Icw)2500 A (1 s)
Breaking Capacity220–240 V: 800 A; 380–440 V: 750 A; 660–690 V: 340 A
Power Loss per Pole3.1 W
Solid Conductor Cable Cross-Section6–95 mm2
Stranded Conductor Cable Cross-Section95 mm2
Flexible Conductor Cross-Section16–70 mm2
Conductor Cross-Section with Ferrule10–70 mm2
Cable section (AWG/MCM)AWG 2/0 (flexible); AWG 3/0 (solid or stranded)
Conductor MaterialCopper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered)
Tightening Torque14 Nm (125 lb-in)
Recommended Screw Driveralyan anahtar 5 mm
Contact TypeRigid bridging link
Contact MaterialSilver
Connection TypeScrew terminal
UL/CSA Rated Insulation Voltage (Ui)600 V AC

Shipping & assurance

For made-to-order products, the procurement and carrier hand-over time is shared with the quotation.

In rare cases, all or part of an order may be unavailable due to stock or procurement updates. In this case, the customer is informed and the relevant product is cancelled and refunded. A product being open for sale does not guarantee that it is in physical store stock.

Delivery and returns