Kraus & Naimer KG125 T206/91 STM Emergency Stop Main Switch, 6-Pole, 125 A, in Enclosure (STM)

Kraus & Naimer KG125 T206/91 STM Emergency Stop Main Switch, 6-Pole, 125 A, in Enclosure (STM)

Kraus & Naimer KG125 T206/91 STM is a 125 A (Ith), 6-pole emergency stop main switch (red handle, yellow front plate); supplied as a maintenance and safety switch in a STM plastic enclosure with conduit entries, IP65, enclosure size 400 x 300 x 172 mm (oversized wiring space). Ratings: rated insulation voltage Ui 1000 V, impulse withstand voltage Uimp 8 kV, AC-21A 125 A, three-phase motor rating at 380–440 V: AC-3 37 kW, AC-23A 45 kW, breaking capacity 800 / 750 / 340 A (220–240 / 380–440 / 660–690 V), maximum fuse 125 A gG, short-time withstand current 2500 A (1 s). Connection: flexible conductors 16–70 mm², solid or stranded conductors 6–95 mm², terminal tightening torque 14 Nm. The enclosure has IP65 protection; a ground terminal and a safety interlocked cover are standard equipment. Codes ending in STM are supplied with conduit entries. It includes 1 NO + 1 NC auxiliary contacts; the auxiliary contacts close after the main contacts close and open before the main contacts open. The KG and C316 series switches exceed the requirements of IEC 60947-3 / EN 60947-3 (VDE 0660 part 107), IEC/EN 60204 and VDE 0113 and are used as switch disconnectors, main switches and maintenance switches.

Number of Poles6P
Rated Current125 A
Mounting TypeSTM ile kutulu (bakım and emniyet şalteri)
IP RatingIP65
SeriesKG125
Size TypeS2
Function CodeT206
Switch FunctionAcil Durdurma Fonksiyonlu Ana Şalter (0-1)
Switch Positions0-1
Number of Positions2
Handle ColorRed (sarı ön plaka)
Conventional Free Air Thermal Current (Ith)125 A
Ambient temperature for rated current50 °C (24 hours, tepe 55 °C)
Conventional Enclosed Thermal Current (Ithe)125 A
Rated Insulation Voltage (Ui)1000 V (AC 50/60 Hz)
Rated Impulse Withstand Voltage (Uimp)8 kV
Overvoltage categoryIII
Pollution Degree3
Rated Operational Current AC-20A (Ie)1000 V: 125 A
Rated Operational Current AC-21A (Ie)20–690 V: 125 A
Rated Operational Current AC-22A (Ie)220–500 V: 125 A; 660–690 V: 100 A
Rated Operational Power AC-3 (Pe)3-phase: 220–240 V 22 kW; 380–440 V 37 kW; 500 V 45 kW; 660–690 V 30 kW
Rated Operational Power AC-23A (Pe)3-phase: 220–240 V 30 kW; 380–440 V 45 kW; 500 V 55 kW; 660–690 V 37 kW
Maximum Fuse CurrentgG 125 A
Rated Short-Time Withstand Current (Icw)2500 A (1 s)
Breaking Capacity220–240 V: 800 A; 380–440 V: 750 A; 660–690 V: 340 A
Power Loss per Pole3.1 W
Solid Conductor Cable Cross-Section6–95 mm2
Stranded Conductor Cable Cross-Section95 mm2
Flexible Conductor Cross-Section16–70 mm2
Conductor Cross-Section with Ferrule10–70 mm2
Cable section (AWG/MCM)AWG 2/0 (flexible); AWG 3/0 (solid or stranded)
Conductor MaterialCopper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered)
Tightening Torque14 Nm (125 lb-in)
Recommended Screw Driveralyan anahtar 5 mm
Contact TypeRigid bridging link
Contact MaterialSilver
Connection TypeScrew terminal
UL/CSA Rated Insulation Voltage (Ui)600 V AC
UL/CSA Thermal Current150 A