Kraus & Naimer KG160 T206/91 STM Emergency Stop Main Switch, 6-Pole, 160 A, in Enclosure (STM)
- Brand: Kraus & Naimer
- SKU: KG160 T206/91 STM
- GTIN: 9004257070664
- MPN: KG160 T206/91 STM
- Model: 160 A
- Price: 60363.69 TRY + VAT · incl. VAT 72436.43 TRY
- Availability: Made to order
- Load Break Switches
- Kraus & Naimer Load Break Switches
- Selection guide: What Is a Load Break Switch? Types and Selection Criteria
Kraus & Naimer KG160 T206/91 STM is a 160 A (Ith), 6-pole emergency stop main switch (red handle, yellow front plate); supplied as a maintenance and safety switch in a STM plastic enclosure with conduit entries, IP65, enclosure size 400 x 300 x 172 mm (oversized wiring space). Ratings: rated insulation voltage Ui 1000 V, impulse withstand voltage Uimp 8 kV, AC-21A 160 A, three-phase motor rating at 380–440 V: AC-3 45 kW, AC-23A 55 kW, breaking capacity 900 / 850 / 340 A (220–240 / 380–440 / 660–690 V), maximum fuse 160 A gG, short-time withstand current 3000 A (1 s). Connection: flexible conductors 16–70 mm², solid or stranded conductors 6–95 mm², terminal tightening torque 14 Nm. The enclosure has IP65 protection; a ground terminal and a safety interlocked cover are standard equipment. Codes ending in STM are supplied with conduit entries. It includes 1 NO + 1 NC auxiliary contacts; the auxiliary contacts close after the main contacts close and open before the main contacts open. The KG and C316 series switches exceed the requirements of IEC 60947-3 / EN 60947-3 (VDE 0660 part 107), IEC/EN 60204 and VDE 0113 and are used as switch disconnectors, main switches and maintenance switches.
| Number of Poles | 6P |
|---|---|
| Rated Current | 160 A |
| Mounting Type | STM ile kutulu (bakım and emniyet şalteri) |
| IP Rating | IP65 |
| Series | KG160 |
| Size Type | S2 |
| Function Code | T206 |
| Switch Function | Acil Durdurma Fonksiyonlu Ana Şalter (0-1) |
| Switch Positions | 0-1 |
| Number of Positions | 2 |
| Handle Color | Red (sarı ön plaka) |
| Conventional Free Air Thermal Current (Ith) | 160 A |
| Ambient temperature for rated current | 50 °C (24 hours, tepe 55 °C) |
| Conventional Enclosed Thermal Current (Ithe) | 160 A |
| Rated Insulation Voltage (Ui) | 1000 V (AC 50/60 Hz) |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Overvoltage category | III |
| Pollution Degree | 3 |
| Rated Operational Current AC-20A (Ie) | 1000 V: 160 A |
| Rated Operational Current AC-21A (Ie) | 20–690 V: 160 A |
| Rated Operational Current AC-22A (Ie) | 220–500 V: 160 A; 660–690 V: 100 A |
| Rated Operational Power AC-3 (Pe) | 3-phase: 220–240 V 30 kW; 380–440 V 45 kW; 500 V 55 kW; 660–690 V 37 kW |
| Rated Operational Power AC-23A (Pe) | 3-phase: 220–240 V 30 kW; 380–440 V 55 kW; 500 V 75 kW; 660–690 V 37 kW |
| Maximum Fuse Current | gG 160 A |
| Rated Short-Time Withstand Current (Icw) | 3000 A (1 s) |
| Breaking Capacity | 220–240 V: 900 A; 380–440 V: 850 A; 660–690 V: 340 A |
| Power Loss per Pole | 5 W |
| Solid Conductor Cable Cross-Section | 6–95 mm2 |
| Stranded Conductor Cable Cross-Section | 95 mm2 |
| Flexible Conductor Cross-Section | 16–70 mm2 |
| Conductor Cross-Section with Ferrule | 10–70 mm2 |
| Cable section (AWG/MCM) | AWG 2/0 (flexible); AWG 3/0 (solid or stranded) |
| Conductor Material | Copper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered) |
| Tightening Torque | 14 Nm (125 lb-in) |
| Recommended Screw Driver | alyan anahtar 5 mm |
| Contact Type | Rigid bridging link |
| Contact Material | Silver |
| Connection Type | Screw terminal |
| UL/CSA Rated Insulation Voltage (Ui) | 600 V AC |
| UL/CSA Thermal Current | 200 A |
Shipping & assurance
For made-to-order products, the procurement and carrier hand-over time is shared with the quotation.
In rare cases, all or part of an order may be unavailable due to stock or procurement updates. In this case, the customer is informed and the relevant product is cancelled and refunded. A product being open for sale does not guarantee that it is in physical store stock.