Schneider Electric LC1D115AEHE TeSys Deca Advanced Contactor 3P 115A AC-3 48-130 V AC/DC

Schneider Electric LC1D115AEHE TeSys Deca Advanced Contactor 3P 115A AC-3 48-130 V AC/DC

LC1D115AEHE is a 3-pole (3NO) TeSys Deca Advanced contactor rated 115 A with a 48-130 V AC/DC coil, suitable for AC-3 motor loads up to 55 kW at 440 V. Electrical characteristics: rated current 115 A; rated operational current (Ie) 115 A (below 60 °C), ≤ 440 V AC AC-3, for the power circuit / 115 A (below 60 °C), ≤ 440 V AC AC-3e, for the power circuit / 200 A (below 60 °C), ≤ 440 V AC AC-1, for the power circuit; utilization category AC-3 / AC-3e / AC-1 / AC-4 / DC-1 / DC-3 / DC-5; rated operational voltage (Ue) power circuit: ≤ 1000 V AC 16.67…400 Hz / power circuit: ≤ 300 V DC; rated impulse withstand voltage (Uimp) 8 kV (IEC 60947); rated control circuit voltage (Uc) 48…130 V AC 50/60 Hz / 48…130 V DC; power pole contact arrangement 3 NO; auxiliary contact configuration 1 NO + 1 NC; conventional free air thermal current (Ith) 200 A (60 °C), for the power circuit; maximum operating rate (cycles/h) 2400 cycles/h, 60 °C / 3600 cycles/h, Uc, 20 ºC; mechanical endurance 8 million cycles; power loss per pole 6 W AC-3 / 6 W AC-3e / 22 W AC-1; hold-in power consumption (VA) 7.5 VA (20 °C); inrush power (VA) 170 VA (20 °C). Mechanical and environmental characteristics: dimensions 97 x 152 x 155 mm (W x H x D); product weight 2.4 kg; mounting support plate; IP rating IP20 front face (IEC 60529); operating ambient temperature -40…60 °C; storage temperature -60…80 °C; operating altitude 0…3000 m (without derating); fire resistance 850 °C (IEC 60695-2-11); certifications CB Scheme / CCC / cULus / CE / UKCA / DNV-GL'den EU-RO-MR. It can be mounted in any orientation, and the LRD43 thermal relay can be mounted directly below the contactor. It is designed for harsh environments such as salt mist, dust and high shock; EverLink gives front IP20 and a robust main power connection. A unique QR code gives quick access to the product data.

Current115 A
Number of Poles3P
SeriesTeSys Deca Advanced
Product Weight2.4 kg
StandardsEN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 60947-4-1; UL 60947-5-1; CSA C22.2 No 60947-4-1; CSA C22.2 No 60947-5-1; JIS C8201-4-1; JIS C8201-5-1; GB/T 14048.4; GB/T 14048.5
Rated Insulation Voltage (Ui)Güç devresi: 600 V CSA sertifikali; Güç devresi: 600 V UL sertifikali; Güç devresi: 1000 V (IEC 60947-4-1); Sinyalleme devresi: 690 V (IEC 60947-1); Sinyalleme devresi: 600 V CSA sertifikali; Sinyalleme devresi: 600 V UL sertifikali
Rated Impulse Withstand Voltage (Uimp)8 kV (IEC 60947)
Width97 mm
IP RatingIP20 ön yüz (IEC 60529)
Height152 mm
Tightening TorqueGüç devresi: 12 N.m - üzerinde konnektör altıgen 4 mm; Kontrol devresi: 1.7 N.m - üzerinde Screw clamp terminals - tornavidayla düz Ø 6 mm; Kontrol devresi: 1.7 N.m - üzerinde Screw clamp terminals - tornavidayla Philips No 2; Kontrol devresi: 1.7 N.m - üzerinde Screw clamp terminals - tornavidayla pozidriv No 2
Depth155 mm
Mechanical Life8 milyon cycles
Electrical Life1 milyon cycles 115 A AC-3 Ue'de ≤ 440 V; 1 milyon cycles 115 A AC-3e Ue'de ≤ 440 V; 0.5 milyon cycles 200 A AC-1 Ue'de ≤ 440 V
CertificationsCB Şeması; CCC; cULus; CE; UKCA; DNV-GL'den EU-RO-MR
Conventional Free Air Thermal Current (Ith)200 A (60 °C), güç devresi için
Contactor ApplicationMotor kontrol; Direnç yükü
Utilization CategoryAC-3; AC-3e; AC-1; AC-4; DC-1; DC-3; DC-5
Operating VoltageGüç devresi: ≤ 1000 V AC 16.67…400 Hz; Güç devresi: ≤ 300 V DC
Rated Operational Current (Ie)115 A (60 °C altında), ≤ 440 V AC AC-3, güç devresi için; 115 A (60 °C altında), ≤ 440 V AC AC-3e, güç devresi için; 200 A (60 °C altında), ≤ 440 V AC AC-1, güç devresi için
Power Pole Contact Arrangement3 NA
Rated Making Capacity (Irms)1560 A, 440 V, güç devresi için (IEC 60947); 140 A AC, sinyalleme devresi için (IEC 60947-5-1); 250 A DC, sinyalleme devresi için (IEC 60947-5-1)
Rated Breaking Capacity1100 A, 440 V, güç devresi için (IEC 60947)
Power Loss per Pole6 W AC-3; 6 W AC-3e; 22 W AC-1
Control Circuit TypeAC (50/60 Hz); DC
Operating Time10...80 ms açma; 20...90 ms kapama
Maximum Operating Rate (cycles/h)2400 cycles/saat, 60 °C; 3600 cycles/saat, Uc, 20 ºC
Auxiliary Contact1 NA + 1 NK
Rated Short-Time Withstand Current (Icw)350 A 40 °C - 10 min, güç devresi için; 600 A 40 °C - 1 min, güç devresi için; 1280 A 40 °C - 10 s, güç devresi için; 1800 A 40 °C - 1 s, güç devresi için; 100 A - 1 s, sinyalleme devresi için; 120 A - 500 ms, sinyalleme devresi için; 140 A - 100 ms, sinyalleme devresi için
Control Voltage48…130 V AC 50/60 Hz; 48…130 V DC
Motor Power (kW)30 kW, 230 V AC 50/60 Hz (AC-3); 55 kW, 400 V AC 50/60 Hz (AC-3); 59 kW, 415 V AC 50/60 Hz (AC-3); 59 kW, 440 V AC 50/60 Hz (AC-3); 75 kW, 500 V AC 50/60 Hz (AC-3); 80 kW, 690 V AC 50/60 Hz (AC-3); 65 kW, 1000 V AC 50/60 Hz (AC-3); 30 kW, 230 V AC 50/60 Hz (AC-3e); 55 kW, 400 V AC 50/60 Hz (AC-3e); 59 kW, 415 V AC 50/60 Hz (AC-3e); 59 kW, 440 V AC 50/60 Hz (AC-3e); 75 kW, 500 V AC 50/60 Hz (AC-3e); 80 kW, 690 V AC 50/60 Hz (AC-3e); 65 kW, 1000 V AC 50/60 Hz (AC-3e); 30 kW, 230 V AC 50/60 Hz (AC-4); 55 kW, 400 V AC 50/60 Hz (AC-4); 55 kW, 440 V AC 50/60 Hz (AC-4); 63 kW, 500 V AC 50/60 Hz (AC-4); 65 kW, 690 V AC 50/60 Hz (AC-4); 50 kW, 1000 V AC 50/60 Hz (AC-4)
Pollution Degree3
Product TypeContactor
Operating Altitude0...3000 m (güç düşürmeden)
Overvoltage categoryIII
Control Circuit Voltage Limits0.8 Uc Min...1.1 Uc Max (-40…60 °C):çalışma AC/DC; 0.1 Uc Max (-40…60 °C):düşme AC/DC
Hold-in Power Consumption (W)5.1 W (20 °C)
Mounting SupportPlate
Fire Resistance850 °C (IEC 60695-2-11)
Motor Power (HP)30 hp, 200/208 V 60 Hz; 40 hp, 230/240 V 60 Hz; 75 hp, 460/480 V 60 Hz; 100 hp, 575/600 V 60 Hz

Shipping & assurance

Products in our store stock are handed over to the carrier on the same day, while products requiring procurement are generally handed over within 1–2 business days.

In rare cases, all or part of an order may be unavailable due to stock or procurement updates. In this case, the customer is informed and the relevant product is cancelled and refunded. A product being open for sale does not guarantee that it is in physical store stock.

Carrier hand-over cut-off

  • Weekdays
  • Saturday

Delivery and returns