Kraus & Naimer C26 A410/TRA301 Star-Delta Cam Switch, 3-Pole, 32 A, in Enclosure (KE03)
- Brand: Kraus & Naimer
- SKU: C26 A410/TRA301
- MPN: C26 A410/TRA301
- Model: 32 A
- Price: 5652.00 TRY + VAT · incl. VAT 6782.40 TRY
- Availability: Made to order
- Star-Delta Switches
- Kraus & Naimer Star-Delta Switches
- Selection guide: What Is Star-Delta Connection? Switch Selection Guide
Kraus & Naimer C26 A410/TRA301 is a 3-pole, 32 A star-delta cam switch. The switch has positions 0-Y-Δ, a switching angle of 60° and 4 levels. It is supplied as an enclosed (TRA) version in a KE03 enclosure (IP65) with an I handle. Front plate code F080; size type S1. Rated insulation voltage is 690 V (AC 50/60 Hz) and rated impulse withstand voltage is 6 kV. AC-21A rated operational current is 32 A over 20–690 V; three-phase AC-3 rated power (380–440 V) is 11 kW; AC-23A rated power (380–440 V) is 15 kW. Maximum fuse rating gG 50 A; rated short-time withstand current 350 A (1 s); power loss per pole 1.3 W. The terminals accept stranded conductors up to 2 x 6 mm²; tightening torque is 1.3 Nm (12 lb-in); operating temperature is -25…+60 °C. It is used for star-delta starting of three-phase asynchronous motors.
| Size Type | S1 |
|---|---|
| Number of Poles | 3P |
| Series | C26 |
| Function Code | A410 |
| Switch Function | Yıldız-Üçgen (0-Y-Δ) |
| Switch Positions | 0-Y-Δ |
| Number of Positions | 3 |
| Switching Angle | 60° ° |
| Number of Levels | 4 |
| Front Plate Code | F080 |
| Rated Current | 32 A |
| Conventional Free Air Thermal Current (Ith) | 32 A |
| Ambient temperature for rated current | 55 °C (24 hours, tepe 60 °C) |
| Conventional Enclosed Thermal Current (Ithe) | 32 A |
| Rated Insulation Voltage (Ui) | 690 V (AC 50/60 Hz) |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Overvoltage category | III |
| Pollution Degree | 3 |
| Rated Operational Current AC-15 (Ie) | 220–240 V: 14 A; 380–440 V: 6 A |
| Rated Operational Current AC-20A (Ie) | 690 V: 32 A |
| Rated Operational Current AC-21A (Ie) | 20–690 V: 32 A |
| Rated Operational Current AC-22A (Ie) | 220–500 V: 32 A; 660–690 V: 32 A |
| Rated Operational Power AC-2 (Pe) | 3-phase: 220–240 V 8 kW; 380–440 V 15 kW; 500 V 18.5 kW; 660–690 V 15 kW |
| Rated Operational Power AC-3 (Pe) | 3-phase: 220–240 V 5.5 kW; 380–440 V 11 kW; 500 V 11 kW; 660–690 V 11 kW. 1-phase: 110–120 V 2.2 kW; 220–240 V 4 kW; 380–440 V 5.5 kW |
| Rated Operational Power AC-4 (Pe) | 3-phase: 220–240 V 2.7 kW; 380–440 V 5.5 kW; 500 V 5.5 kW; 660–690 V 5.5 kW. 1-phase: 110–120 V 0.75 kW; 220–240 V 1.5 kW; 380–440 V 3 kW |
| Rated Operational Power AC-23A (Pe) | 3-phase: 220–240 V 7.5 kW; 380–440 V 15 kW; 500 V 15 kW; 660–690 V 15 kW. 1-phase: 110–120 V 2.2 kW; 220–240 V 4 kW; 380–440 V 7.5 kW |
| Maximum Fuse Current | gG 50 A |
| Rated Short-Time Withstand Current (Icw) | 350 A (1 s) |
| Breaking Capacity | 220–240 V: 280 A; 380–440 V: 250 A; 660–690 V: 150 A |
| Power Loss per Pole | 1.3 W |
| Solid Conductor Cable Cross-Section | 1–6 mm2 |
| Stranded Conductor Cable Cross-Section | 2x6 mm2 |
| Flexible Conductor Cross-Section | 1.5–6 mm2 |
| Conductor Cross-Section with Ferrule | 1–4 mm2 |
| Cable section (AWG/MCM) | AWG 10 (flexible); AWG 8 (solid or stranded) |
| Conductor Material | Copper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered) |
| Tightening Torque | 1.3 Nm (12 lb-in) |
| Recommended Screw Driver | Pozidriv/Phillips PH2; slotted 1 x 5.5 mm (DIN 5264) |
| Contact Type | Rigid bridging link |
| Contact Material | Silver |
Shipping & assurance
For made-to-order products, the procurement and carrier hand-over time is shared with the quotation.
In rare cases, all or part of an order may be unavailable due to stock or procurement updates. In this case, the customer is informed and the relevant product is cancelled and refunded. A product being open for sale does not guarantee that it is in physical store stock.