Kraus & Naimer C26 A425 Split-Phase Motor Start Cam Switch, 32 A, 64 x 64 mm Front Plate
- Brand: Kraus & Naimer
- SKU: C26 A425
- MPN: C26 A425
- Model: 32 A
- Price: 2019.00 TRY + VAT · incl. VAT 2422.80 TRY
- Availability: Made to order
- Single-Phase Motor Starting Switches
- Selection guide: Cam Switches Selection Guide
Kraus & Naimer C26 A425 is a 32 A cam switch with 0-1-START positions for starting single-phase split-phase motors with an auxiliary start winding. Technical values: C26 type, size class S1, 64 x 64 mm front plate; thermal current Ith 32 A (55 °C), enclosed thermal current Ithe 32 A; rated insulation voltage Ui 690 V, rated impulse withstand voltage Uimp 6 kV; AC-21A 32 A, AC-22A 32 A, AC-15 380–440 V 6 A; single-phase motor rating at 220–240 V: AC-3 4 kW, AC-23A 4 kW; maximum gG 50 A fuse, Icw 350 A (1 s); conductor cross-section: solid 1–6 mm², flexible 1.5–6 mm²; tightening torque 1.3 Nm; 2 levels, positions 0-1-START, switching angle 90° + 30°. Values are given in accordance with IEC 60947-3 and EN 60947-3. It is used to run single-phase motors with an auxiliary (start) winding; the START position connects the auxiliary winding.
| Series | C26 |
|---|---|
| Size Type | S1 |
| Function Code | A425 |
| Switch Function | Tek Fazlı Yardımcı Sargılı Motor (0-1-START) |
| Switch Positions | 0-1-START |
| Number of Positions | 3 |
| Switching Angle | 90° + 30° ° |
| Number of Levels | 2 |
| Front Plate Code | F119 |
| Front Plate Size (A x B) | 64 x 64 mm |
| Rated Current | 32 A |
| Conventional Free Air Thermal Current (Ith) | 32 A |
| Ambient temperature for rated current | 55 °C (24 hours, tepe 60 °C) |
| Conventional Enclosed Thermal Current (Ithe) | 32 A |
| Rated Insulation Voltage (Ui) | 690 V (AC 50/60 Hz) |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Overvoltage category | III |
| Pollution Degree | 3 |
| Rated Operational Current AC-15 (Ie) | 220–240 V: 14 A; 380–440 V: 6 A |
| Rated Operational Current AC-20A (Ie) | 690 V: 32 A |
| Rated Operational Current AC-21A (Ie) | 20–690 V: 32 A |
| Rated Operational Current AC-22A (Ie) | 220–500 V: 32 A; 660–690 V: 32 A |
| Rated Operational Power AC-2 (Pe) | 3-phase: 220–240 V 8 kW; 380–440 V 15 kW; 500 V 18.5 kW; 660–690 V 15 kW |
| Rated Operational Power AC-3 (Pe) | 3-phase: 220–240 V 5.5 kW; 380–440 V 11 kW; 500 V 11 kW; 660–690 V 11 kW. 1-phase: 110–120 V 2.2 kW; 220–240 V 4 kW; 380–440 V 5.5 kW |
| Rated Operational Power AC-4 (Pe) | 3-phase: 220–240 V 2.7 kW; 380–440 V 5.5 kW; 500 V 5.5 kW; 660–690 V 5.5 kW. 1-phase: 110–120 V 0.75 kW; 220–240 V 1.5 kW; 380–440 V 3 kW |
| Rated Operational Power AC-23A (Pe) | 3-phase: 220–240 V 7.5 kW; 380–440 V 15 kW; 500 V 15 kW; 660–690 V 15 kW. 1-phase: 110–120 V 2.2 kW; 220–240 V 4 kW; 380–440 V 7.5 kW |
| Maximum Fuse Current | gG 50 A |
| Rated Short-Time Withstand Current (Icw) | 350 A (1 s) |
| Breaking Capacity | 220–240 V: 280 A; 380–440 V: 250 A; 660–690 V: 150 A |
| Power Loss per Pole | 1.3 W |
| Solid Conductor Cable Cross-Section | 1–6 mm2 |
| Stranded Conductor Cable Cross-Section | 2x6 mm2 |
| Flexible Conductor Cross-Section | 1.5–6 mm2 |
| Conductor Cross-Section with Ferrule | 1–4 mm2 |
| Cable section (AWG/MCM) | AWG 10 (flexible); AWG 8 (solid or stranded) |
| Conductor Material | Copper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered) |
| Tightening Torque | 1.3 Nm (12 lb-in) |
| Recommended Screw Driver | Pozidriv/Phillips PH2; slotted 1 x 5.5 mm (DIN 5264) |
| Contact Type | Rigid bridging link |
| Contact Material | Silver |
Shipping & assurance
For made-to-order products, the procurement and carrier hand-over time is shared with the quotation.
In rare cases, all or part of an order may be unavailable due to stock or procurement updates. In this case, the customer is informed and the relevant product is cancelled and refunded. A product being open for sale does not guarantee that it is in physical store stock.