Kraus & Naimer C32 A425 Split-Phase Motor Start Cam Switch, 50 A, 64 x 64 mm Front Plate

Kraus & Naimer C32 A425 Split-Phase Motor Start Cam Switch, 50 A, 64 x 64 mm Front Plate

Kraus & Naimer C32 A425 is a 50 A cam switch with 0-1-START positions for starting single-phase split-phase motors with an auxiliary start winding. Technical values: C32 type, size class S1, 64 x 64 mm front plate; thermal current Ith 50 A (55 °C), enclosed thermal current Ithe 50 A; rated insulation voltage Ui 690 V, rated impulse withstand voltage Uimp 6 kV; AC-21A 40 A, AC-22A 40 A, AC-15 380–440 V 7 A; single-phase motor rating at 220–240 V: AC-3 5.5 kW, AC-23A 5.5 kW; maximum gG 63 A fuse, Icw 800 A (1 s); conductor cross-section: solid 1–10 mm², flexible 1.5–6 mm²; tightening torque 2.2 Nm; 2 levels, positions 0-1-START, switching angle 90° + 30°. Values are given in accordance with IEC 60947-3 and EN 60947-3. It is used to run single-phase motors with an auxiliary (start) winding; the START position connects the auxiliary winding.

SeriesC32
Size TypeS1
Function CodeA425
Switch FunctionTek Fazlı Yardımcı Sargılı Motor (0-1-START)
Switch Positions0-1-START
Number of Positions3
Switching Angle90° + 30° °
Number of Levels2
Front Plate CodeF119
Front Plate Size (A x B)64 x 64 mm
Rated Current50 A
Conventional Free Air Thermal Current (Ith)50 A
Ambient temperature for rated current55 °C (24 hours, tepe 60 °C)
Conventional Enclosed Thermal Current (Ithe)50 A
Rated Insulation Voltage (Ui)690 V (AC 50/60 Hz)
Rated Impulse Withstand Voltage (Uimp)6 kV
Overvoltage categoryIII
Pollution Degree3
Rated Operational Current AC-15 (Ie)220–240 V: 16 A; 380–440 V: 7 A
Rated Operational Current AC-20A (Ie)690 V: 50 A
Rated Operational Current AC-21A (Ie)20–690 V: 40 A
Rated Operational Current AC-22A (Ie)220–500 V: 40 A; 660–690 V: 40 A
Rated Operational Power AC-2 (Pe)3-phase: 220–240 V 10 kW; 380–440 V 18.5 kW; 500 V 22 kW; 660–690 V 22 kW
Rated Operational Power AC-3 (Pe)3-phase: 220–240 V 7.5 kW; 380–440 V 15 kW; 500 V 15 kW; 660–690 V 15 kW. 1-phase: 110–120 V 2.5 kW; 220–240 V 5.5 kW; 380–440 V 7.5 kW
Rated Operational Power AC-4 (Pe)3-phase: 220–240 V 3.7 kW; 380–440 V 6 kW; 500 V 6 kW; 660–690 V 6 kW. 1-phase: 110–120 V 1.1 kW; 220–240 V 2.2 kW; 380–440 V 3.7 kW
Rated Operational Power AC-23A (Pe)3-phase: 220–240 V 11 kW; 380–440 V 22 kW; 500 V 30 kW; 660–690 V 22 kW. 1-phase: 110–120 V 2.5 kW; 220–240 V 5.5 kW; 380–440 V 11 kW
Maximum Fuse CurrentgG 63 A
Rated Short-Time Withstand Current (Icw)800 A (1 s)
Breaking Capacity220–240 V: 380 A; 380–440 V: 360 A; 660–690 V: 270 A
Power Loss per Pole1.3 W
Solid Conductor Cable Cross-Section1–10 mm2
Stranded Conductor Cable Cross-Section2x10 mm2
Flexible Conductor Cross-Section1.5–6 mm2
Conductor Cross-Section with Ferrule1–6 mm2
Cable section (AWG/MCM)AWG 8
Conductor MaterialCopper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered)
Tightening Torque2.2 Nm (19.5 lb-in)
Recommended Screw DriverPozidriv/Phillips PH2; slotted 1.2 x 8 mm (DIN 5264)
Contact TypeRigid bridging link
Contact MaterialSilver

Shipping & assurance

For made-to-order products, the procurement and carrier hand-over time is shared with the quotation.

In rare cases, all or part of an order may be unavailable due to stock or procurement updates. In this case, the customer is informed and the relevant product is cancelled and refunded. A product being open for sale does not guarantee that it is in physical store stock.

Delivery and returns