Kraus & Naimer C26 A233 6-Step Cam Switch without OFF, 1-Pole, 32 A, 64 x 64 mm Front Plate

Kraus & Naimer C26 A233 6-Step Cam Switch without OFF, 1-Pole, 32 A, 64 x 64 mm Front Plate

Kraus & Naimer C26 A233 is a 1-pole, 32 A step cam switch with 6 steps (1-6) and no OFF position. Technical values: C26 type, size class S1, 64 x 64 mm front plate; thermal current Ith 32 A (55 °C), enclosed thermal current Ithe 32 A; rated insulation voltage Ui 690 V, rated impulse withstand voltage Uimp 6 kV; AC-21A 32 A, AC-22A 32 A, AC-15 380–440 V 6 A; maximum gG 50 A fuse, Icw 350 A (1 s); conductor cross-section: solid 1–6 mm², flexible 1.5–6 mm²; tightening torque 1.3 Nm; 1 pole, 3 levels, 6 steps, positions 1-2-3-4-5-6, switching angle 60°. Values are given in accordance with IEC 60947-3 and EN 60947-3. It is used in control and adjustment circuits that need selection between several circuits or steps; none of the 6 positions is an OFF position.

Size TypeS1
Number of Poles1P
Cam Switch Position Count6 Positions
SeriesC26
Function CodeA233
Switch FunctionStepped Without Off (1-2-3-4-5-6)
Switch Positions1-2-3-4-5-6
Number of Positions6
Switching Angle60° °
Number of Levels3
Front Plate CodeF079
Front Plate Size (A x B)64 x 64 mm
Rated Current32 A
Conventional Free Air Thermal Current (Ith)32 A
Ambient temperature for rated current55 °C (24 hours, tepe 60 °C)
Conventional Enclosed Thermal Current (Ithe)32 A
Rated Insulation Voltage (Ui)690 V (AC 50/60 Hz)
Rated Impulse Withstand Voltage (Uimp)6 kV
Overvoltage categoryIII
Pollution Degree3
Rated Operational Current AC-15 (Ie)220–240 V: 14 A; 380–440 V: 6 A
Rated Operational Current AC-20A (Ie)690 V: 32 A
Rated Operational Current AC-21A (Ie)20–690 V: 32 A
Rated Operational Current AC-22A (Ie)220–500 V: 32 A; 660–690 V: 32 A
Rated Operational Power AC-2 (Pe)3-phase: 220–240 V 8 kW; 380–440 V 15 kW; 500 V 18.5 kW; 660–690 V 15 kW
Rated Operational Power AC-3 (Pe)3-phase: 220–240 V 5.5 kW; 380–440 V 11 kW; 500 V 11 kW; 660–690 V 11 kW. 1-phase: 110–120 V 2.2 kW; 220–240 V 4 kW; 380–440 V 5.5 kW
Rated Operational Power AC-4 (Pe)3-phase: 220–240 V 2.7 kW; 380–440 V 5.5 kW; 500 V 5.5 kW; 660–690 V 5.5 kW. 1-phase: 110–120 V 0.75 kW; 220–240 V 1.5 kW; 380–440 V 3 kW
Rated Operational Power AC-23A (Pe)3-phase: 220–240 V 7.5 kW; 380–440 V 15 kW; 500 V 15 kW; 660–690 V 15 kW. 1-phase: 110–120 V 2.2 kW; 220–240 V 4 kW; 380–440 V 7.5 kW
Maximum Fuse CurrentgG 50 A
Rated Short-Time Withstand Current (Icw)350 A (1 s)
Breaking Capacity220–240 V: 280 A; 380–440 V: 250 A; 660–690 V: 150 A
Power Loss per Pole1.3 W
Solid Conductor Cable Cross-Section1–6 mm2
Stranded Conductor Cable Cross-Section2x6 mm2
Flexible Conductor Cross-Section1.5–6 mm2
Conductor Cross-Section with Ferrule1–4 mm2
Cable section (AWG/MCM)AWG 10 (flexible); AWG 8 (solid or stranded)
Conductor MaterialCopper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered)
Tightening Torque1.3 Nm (12 lb-in)
Recommended Screw DriverPozidriv/Phillips PH2; slotted 1 x 5.5 mm (DIN 5264)

Shipping & assurance

For made-to-order products, the procurement and carrier hand-over time is shared with the quotation.

In rare cases, all or part of an order may be unavailable due to stock or procurement updates. In this case, the customer is informed and the relevant product is cancelled and refunded. A product being open for sale does not guarantee that it is in physical store stock.

Delivery and returns