Kraus & Naimer C32 A241 3-Step Cam Switch with OFF, 1-Pole, 50 A, 64 x 64 mm Front Plate

Kraus & Naimer C32 A241 3-Step Cam Switch with OFF, 1-Pole, 50 A, 64 x 64 mm Front Plate

Kraus & Naimer C32 A241 is a 1-pole step cam switch with 3 steps and an OFF (0) position; thermal current 50 A, front plate size 64 x 64 mm. The handle of the C32 A241 turns in 45° steps through the positions 0-1-2-3, and each position engages a different contact arrangement; number of levels 2, front plate code F109. It is used in multi-position selection and control circuits. For C32 A241, rated insulation voltage Ui is 690 V, AC-21A rated current is 40 A, maximum fuse rating is gG 63 A and rated short-time withstand current Icw is 800 A (1 s). C32 A241 is connected by screw terminals: flexible conductors of 1.5–6 mm², conductors with ferrule of 1–6 mm² and stranded conductors of 2 x 10 mm² can be connected; tightening torque is 2.2 Nm.

Size TypeS1
Number of Poles1P
Cam Switch Position Count3 Positions
SeriesC32
Function CodeA241
Switch FunctionStepped With Off (0-1-2-3)
Switch Positions0-1-2-3
Number of Positions4
Switching Angle45° °
Number of Levels2
Front Plate CodeF109
Front Plate Size (A x B)64 x 64 mm
Rated Current50 A
Conventional Free Air Thermal Current (Ith)50 A
Ambient temperature for rated current55 °C (24 hours, tepe 60 °C)
Conventional Enclosed Thermal Current (Ithe)50 A
Rated Insulation Voltage (Ui)690 V (AC 50/60 Hz)
Rated Impulse Withstand Voltage (Uimp)6 kV
Overvoltage categoryIII
Pollution Degree3
Rated Operational Current AC-15 (Ie)220–240 V: 16 A; 380–440 V: 7 A
Rated Operational Current AC-20A (Ie)690 V: 50 A
Rated Operational Current AC-21A (Ie)20–690 V: 40 A
Rated Operational Current AC-22A (Ie)220–500 V: 40 A; 660–690 V: 40 A
Rated Operational Power AC-2 (Pe)3-phase: 220–240 V 10 kW; 380–440 V 18.5 kW; 500 V 22 kW; 660–690 V 22 kW
Rated Operational Power AC-3 (Pe)3-phase: 220–240 V 7.5 kW; 380–440 V 15 kW; 500 V 15 kW; 660–690 V 15 kW. 1-phase: 110–120 V 2.5 kW; 220–240 V 5.5 kW; 380–440 V 7.5 kW
Rated Operational Power AC-4 (Pe)3-phase: 220–240 V 3.7 kW; 380–440 V 6 kW; 500 V 6 kW; 660–690 V 6 kW. 1-phase: 110–120 V 1.1 kW; 220–240 V 2.2 kW; 380–440 V 3.7 kW
Rated Operational Power AC-23A (Pe)3-phase: 220–240 V 11 kW; 380–440 V 22 kW; 500 V 30 kW; 660–690 V 22 kW. 1-phase: 110–120 V 2.5 kW; 220–240 V 5.5 kW; 380–440 V 11 kW
Maximum Fuse CurrentgG 63 A
Rated Short-Time Withstand Current (Icw)800 A (1 s)
Breaking Capacity220–240 V: 380 A; 380–440 V: 360 A; 660–690 V: 270 A
Power Loss per Pole1.3 W
Solid Conductor Cable Cross-Section1–10 mm2
Stranded Conductor Cable Cross-Section2x10 mm2
Flexible Conductor Cross-Section1.5–6 mm2
Conductor Cross-Section with Ferrule1–6 mm2
Cable section (AWG/MCM)AWG 8
Conductor MaterialCopper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered)
Tightening Torque2.2 Nm (19.5 lb-in)
Recommended Screw DriverPozidriv/Phillips PH2; slotted 1.2 x 8 mm (DIN 5264)

Shipping & assurance

For made-to-order products, the procurement and carrier hand-over time is shared with the quotation.

In rare cases, all or part of an order may be unavailable due to stock or procurement updates. In this case, the customer is informed and the relevant product is cancelled and refunded. A product being open for sale does not guarantee that it is in physical store stock.

Delivery and returns