Kraus & Naimer C80 A283 5-Step Cam Switch with OFF, 3-Pole, 115 A, 88 x 88 mm Front Plate

Kraus & Naimer C80 A283 5-Step Cam Switch with OFF, 3-Pole, 115 A, 88 x 88 mm Front Plate

Kraus & Naimer C80 A283 is a 3-pole, 115 A step switch with 5 steps and an OFF position. The switch has positions 0-1-2-3-4-5, a switching angle of 30° and 8 levels. Front plate size 88 x 88 mm; front plate code F003; size type S2. Rated insulation voltage is 690 V (AC 50/60 Hz) and rated impulse withstand voltage is 6 kV. AC-21A rated operational current is 100 A over 20–690 V; three-phase AC-3 rated power (380–440 V) is 30 kW; AC-23A rated power (380–440 V) is 45 kW. Maximum fuse rating gG 125 A; rated short-time withstand current 1300 A (1 s); power loss per pole 5.8 W. The terminals accept stranded conductors up to 35 mm²; tightening torque is 4 Nm (35 lb-in); operating temperature is -25…+60 °C. It is used to select between several circuit steps; the circuit is open in the 0 position.

Size TypeS2
Number of Poles3P
Cam Switch Position Count5 Positions
SeriesC80
Function CodeA283
Switch FunctionStepped With Off (0-1-2-3-4-5)
Switch Positions0-1-2-3-4-5
Number of Positions6
Switching Angle30° °
Number of Levels8
Front Plate CodeF003
Front Plate Size (A x B)88 x 88 mm
Rated Current115 A
Conventional Free Air Thermal Current (Ith)115 A
Ambient temperature for rated current55 °C (24 hours, tepe 60 °C)
Conventional Enclosed Thermal Current (Ithe)115 A
Rated Insulation Voltage (Ui)690 V (AC 50/60 Hz)
Rated Impulse Withstand Voltage (Uimp)6 kV
Overvoltage categoryIII
Pollution Degree3
Rated Operational Current AC-20A (Ie)690 V: 115 A
Rated Operational Current AC-21A (Ie)20–690 V: 100 A
Rated Operational Current AC-22A (Ie)220–500 V: 100 A; 660–690 V: 100 A
Rated Operational Power AC-2 (Pe)3-phase: 220–240 V 30 kW; 380–440 V 45 kW; 500 V 55 kW; 660–690 V 55 kW
Rated Operational Power AC-3 (Pe)3-phase: 220–240 V 15 kW; 380–440 V 30 kW; 500 V 30 kW; 660–690 V 30 kW. 1-phase: 110–120 V 3.7 kW; 220–240 V 7.5 kW; 380–440 V 13 kW
Rated Operational Power AC-4 (Pe)3-phase: 220–240 V 6 kW; 380–440 V 11 kW; 500 V 11 kW; 660–690 V 11 kW. 1-phase: 110–120 V 1.5 kW; 220–240 V 3 kW; 380–440 V 5.5 kW
Rated Operational Power AC-23A (Pe)3-phase: 220–240 V 30 kW; 380–440 V 45 kW; 500 V 55 kW; 660–690 V 45 kW. 1-phase: 110–120 V 5.5 kW; 220–240 V 15 kW; 380–440 V 22 kW
Maximum Fuse CurrentgG 125 A
Rated Short-Time Withstand Current (Icw)1300 A (1 s)
Breaking Capacity220–240 V: 860 A; 380–440 V: 860 A; 660–690 V: 400 A
Power Loss per Pole5.8 W
Solid Conductor Cable Cross-Section2.5–35 mm2
Stranded Conductor Cable Cross-Section35 mm2
Flexible Conductor Cross-Section6–25 mm2
Conductor Cross-Section with Ferrule4–25 mm2
Cable section (AWG/MCM)AWG 3 (flexible); AWG 2 (solid or stranded)
Conductor MaterialCopper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered)
Tightening Torque4 Nm (35 lb-in)
Recommended Screw DriverPozidriv/Phillips PH2; slotted 1.2 x 8 mm (DIN 5264)
Contact TypeRigid bridging link