Kraus & Naimer CA10B A242 4-Step Cam Switch with OFF, 1-Pole, 20 A, 64 x 64 mm Front Plate
- Brand: Kraus & Naimer
- SKU: CA10B A242
- MPN: CA10B A242
- Model: 20 A
- Price: 1457.00 TRY + VAT · incl. VAT 1748.40 TRY
- Availability: Made to order
- Standard Step Switches
- Kraus & Naimer Standard Step Switches
- Selection guide: Standard Step Switches Selection Guide
Kraus & Naimer CA10B A242 is a 1-pole step cam switch with 4 steps and an OFF (0) position; thermal current 20 A, front plate size 64 x 64 mm. The handle of the CA10B A242 turns in 30° steps through the positions 0-1-2-3-4, and each position engages a different contact arrangement; number of levels 2, front plate code F002. It is used in multi-position selection and control circuits. For CA10B A242, rated insulation voltage Ui is 690 V, AC-21A rated current is 20 A, maximum fuse rating is gG 25 A and rated short-time withstand current Icw is 140 A (1 s). CA10B A242 is connected by screw terminals: flexible conductors of 0.75–2.5 mm², conductors with ferrule of 0.5–2.5 mm² and stranded conductors of 2 x 2.5 mm² can be connected; tightening torque is 0.6 Nm.
| Size Type | S1 |
|---|---|
| Number of Poles | 1P |
| Cam Switch Position Count | 4 Positions |
| Series | CA10B |
| Function Code | A242 |
| Switch Function | Stepped With Off (0-1-2-3-4) |
| Switch Positions | 0-1-2-3-4 |
| Number of Positions | 5 |
| Switching Angle | 30° ° |
| Number of Levels | 2 |
| Front Plate Code | F002 |
| Front Plate Size (A x B) | 64 x 64 mm |
| Rated Current | 20 A |
| Conventional Free Air Thermal Current (Ith) | 20 A |
| Ambient temperature for rated current | 55 °C (24 hours, tepe 60 °C) |
| Conventional Enclosed Thermal Current (Ithe) | 20 A |
| Rated Insulation Voltage (Ui) | 690 V (AC 50/60 Hz) |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV (circuit breaker); 4 kV (switch-disconnector) |
| Overvoltage category | III |
| Pollution Degree | 3 |
| Rated Operational Current AC-15 (Ie) | 220–240 V: 6 A; 380–440 V: 4 A |
| Rated Operational Current AC-20A (Ie) | 690 V: 20 A |
| Rated Operational Current AC-21A (Ie) | 20–690 V: 20 A |
| Rated Operational Current AC-22A (Ie) | 220–500 V: 20 A; 660–690 V: 20 A |
| Rated Operational Power AC-2 (Pe) | 3-phase: 220–240 V 4 kW; 380–440 V 7.5 kW; 500 V 10 kW; 660–690 V 10 kW |
| Rated Operational Power AC-3 (Pe) | 3-phase: 220–240 V 3 kW; 380–440 V 5.5 kW; 500 V 5.5 kW; 660–690 V 5.5 kW. 1-phase: 110–120 V 0.6 kW; 220–240 V 2.2 kW; 380–440 V 3 kW |
| Rated Operational Power AC-4 (Pe) | 3-phase: 220–240 V 0.55 kW; 380–440 V 1.5 kW; 500 V 1.5 kW; 660–690 V 1.5 kW. 1-phase: 110–120 V 0.3 kW; 220–240 V 0.75 kW; 380–440 V 1.5 kW |
| Rated Operational Power AC-23A (Pe) | 3-phase: 220–240 V 3.7 kW; 380–440 V 7.5 kW; 500 V 7.5 kW; 660–690 V 7.5 kW. 1-phase: 110–120 V 0.75 kW; 220–240 V 2.5 kW; 380–440 V 3.7 kW |
| Maximum Fuse Current | gG 25 A |
| Rated Short-Time Withstand Current (Icw) | 140 A (1 s) |
| Breaking Capacity | 220–240 V: 150 A; 380–440 V: 150 A; 660–690 V: 80 A |
| Power Loss per Pole | 0.9 W |
| Solid Conductor Cable Cross-Section | 0.5–2.5 mm2 |
| Stranded Conductor Cable Cross-Section | 2x2.5 mm2 |
| Flexible Conductor Cross-Section | 0.75–2.5 mm2 |
| Conductor Cross-Section with Ferrule | 0.5–2.5 mm2 |
| Cable section (AWG/MCM) | AWG 14 (flexible); AWG 12 (solid or stranded) |
| Conductor Material | Copper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered) |
| Tightening Torque | 0.6 Nm (5 lb-in) |
| Recommended Screw Driver | Pozidriv/Phillips PH1; slotted 0.8 x 4 mm (DIN 5264) |
Shipping & assurance
For made-to-order products, the procurement and carrier hand-over time is shared with the quotation.
In rare cases, all or part of an order may be unavailable due to stock or procurement updates. In this case, the customer is informed and the relevant product is cancelled and refunded. A product being open for sale does not guarantee that it is in physical store stock.