Kraus & Naimer CA20 A260 2-Step Cam Switch with OFF, 2-Pole, 25 A, 48 x 48 mm Front Plate
- Brand: Kraus & Naimer
- SKU: CA20 A260
- MPN: CA20 A260
- Model: 25 A
- Price: 1915.00 TRY + VAT · incl. VAT 2298.00 TRY
- Availability: Made to order
- Standard Step Switches
- Kraus & Naimer Standard Step Switches
- Selection guide: Standard Step Switches Selection Guide
Kraus & Naimer CA20 A260 is a 2-pole step cam switch with 2 steps and an OFF (0) position; thermal current 25 A, front plate size 48 x 48 mm. The handle of the CA20 A260 turns in 50° steps through the positions 0-1-2, and each position engages a different contact arrangement; number of levels 2, front plate code F075. It is used in multi-position selection and control circuits. For CA20 A260, rated insulation voltage Ui is 690 V, AC-21A rated current is 25 A, maximum fuse rating is gG 35 A and rated short-time withstand current Icw is 280 A (1 s). Single-phase AC-3 motor rating is 3 kW at 220–240 V and 3.7 kW at 380–440 V. CA20 A260 is connected by screw terminals: flexible conductors of 1.5–4 mm², conductors with ferrule of 1–2.5 mm² and stranded conductors of 2 x 4 mm² can be connected; tightening torque is 1 Nm.
| Size Type | S0 |
|---|---|
| Number of Poles | 2P |
| Cam Switch Position Count | 2 Positions |
| Series | CA20 |
| Function Code | A260 |
| Switch Function | Stepped With Off (0-1-2) |
| Switch Positions | 0-1-2 |
| Number of Positions | 3 |
| Switching Angle | 50° ° |
| Number of Levels | 2 |
| Front Plate Code | F075 |
| Front Plate Size (A x B) | 48 x 48 mm |
| Rated Current | 25 A |
| Conventional Free Air Thermal Current (Ith) | 25 A |
| Ambient temperature for rated current | 55 °C (24 hours, tepe 60 °C) |
| Conventional Enclosed Thermal Current (Ithe) | 25 A |
| Rated Insulation Voltage (Ui) | 690 V (AC 50/60 Hz) |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Overvoltage category | III |
| Pollution Degree | 3 |
| Rated Operational Current AC-15 (Ie) | 220–240 V: 8 A; 380–440 V: 5 A |
| Rated Operational Current AC-20A (Ie) | 690 V: 25 A |
| Rated Operational Current AC-21A (Ie) | 20–690 V: 25 A |
| Rated Operational Current AC-22A (Ie) | 220–500 V: 25 A; 660–690 V: 25 A |
| Rated Operational Power AC-2 (Pe) | 3-phase: 220–240 V 5.5 kW; 380–440 V 11 kW; 500 V 15 kW; 660–690 V 13 kW |
| Rated Operational Power AC-3 (Pe) | 3-phase: 220–240 V 4 kW; 380–440 V 7.5 kW; 500 V 7.5 kW; 660–690 V 7.5 kW. 1-phase: 110–120 V 1.5 kW; 220–240 V 3 kW; 380–440 V 3.7 kW |
| Rated Operational Power AC-4 (Pe) | 3-phase: 220–240 V 1.5 kW; 380–440 V 3 kW; 500 V 3 kW; 660–690 V 3 kW. 1-phase: 110–120 V 0.45 kW; 220–240 V 1.1 kW; 380–440 V 2.2 kW |
| Rated Operational Power AC-23A (Pe) | 3-phase: 220–240 V 5.5 kW; 380–440 V 11 kW; 500 V 11 kW; 660–690 V 11 kW. 1-phase: 110–120 V 1.5 kW; 220–240 V 3 kW; 380–440 V 5.5 kW |
| Maximum Fuse Current | gG 35 A |
| Rated Short-Time Withstand Current (Icw) | 280 A (1 s) |
| Breaking Capacity | 220–240 V: 200 A; 380–440 V: 200 A; 660–690 V: 125 A |
| Power Loss per Pole | 0.9 W |
| Solid Conductor Cable Cross-Section | 0.75–4 mm2 |
| Stranded Conductor Cable Cross-Section | 2x4 mm2 |
| Flexible Conductor Cross-Section | 1.5–4 mm2 |
| Conductor Cross-Section with Ferrule | 1–2.5 mm2 |
| Cable section (AWG/MCM) | AWG 12 (flexible); AWG 10 (solid or stranded) |
| Conductor Material | Copper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered) |
| Tightening Torque | 1 Nm (9 lb-in) |
| Recommended Screw Driver | Pozidriv/Phillips PH1; slotted 0.8 x 5.5 mm (DIN 5264) |
Shipping & assurance
For made-to-order products, the procurement and carrier hand-over time is shared with the quotation.