Kraus & Naimer C32 A284 6-Step Cam Switch with OFF, 3-Pole, 50 A, 64 x 64 mm Front Plate
- Brand: Kraus & Naimer
- SKU: C32 WAA284
- MPN: C32 WAA284
- Model: 50 A
- Price: 10618.00 TRY + VAT · incl. VAT 12741.60 TRY
- Availability: Made to order
- Standard Step Switches
- Kraus & Naimer Standard Step Switches
- Selection guide: Standard Step Switches Selection Guide
Kraus & Naimer C32 A284 is a 3-pole, 50 A step switch with 6 steps and an OFF position. The switch has positions 0-1-2-3-4-5-6, a switching angle of 30° and 9 levels. Front plate size 64 x 64 mm; front plate code F004; size type S1. Rated insulation voltage is 690 V (AC 50/60 Hz) and rated impulse withstand voltage is 6 kV. AC-21A rated operational current is 40 A over 20–690 V; three-phase AC-3 rated power (380–440 V) is 15 kW; AC-23A rated power (380–440 V) is 22 kW. Maximum fuse rating gG 63 A; rated short-time withstand current 800 A (1 s); power loss per pole 1.3 W. The terminals accept stranded conductors up to 2 x 10 mm²; tightening torque is 2.2 Nm (19.5 lb-in); operating temperature is -25…+60 °C. It is used to select between several circuit steps; the circuit is open in the 0 position.
| Size Type | S1 |
|---|---|
| Number of Poles | 3P |
| Cam Switch Position Count | 6 Positions |
| Series | C32 |
| Function Code | A284 |
| Switch Function | Stepped With Off (0-1-2-3-4-5-6) |
| Switch Positions | 0-1-2-3-4-5-6 |
| Number of Positions | 7 |
| Switching Angle | 30° ° |
| Number of Levels | 9 |
| Front Plate Code | F004 |
| Front Plate Size (A x B) | 64 x 64 mm |
| Rated Current | 50 A |
| Conventional Free Air Thermal Current (Ith) | 50 A |
| Ambient temperature for rated current | 55 °C (24 hours, tepe 60 °C) |
| Conventional Enclosed Thermal Current (Ithe) | 50 A |
| Rated Insulation Voltage (Ui) | 690 V (AC 50/60 Hz) |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Overvoltage category | III |
| Pollution Degree | 3 |
| Rated Operational Current AC-15 (Ie) | 220–240 V: 16 A; 380–440 V: 7 A |
| Rated Operational Current AC-20A (Ie) | 690 V: 50 A |
| Rated Operational Current AC-21A (Ie) | 20–690 V: 40 A |
| Rated Operational Current AC-22A (Ie) | 220–500 V: 40 A; 660–690 V: 40 A |
| Rated Operational Power AC-2 (Pe) | 3-phase: 220–240 V 10 kW; 380–440 V 18.5 kW; 500 V 22 kW; 660–690 V 22 kW |
| Rated Operational Power AC-3 (Pe) | 3-phase: 220–240 V 7.5 kW; 380–440 V 15 kW; 500 V 15 kW; 660–690 V 15 kW. 1-phase: 110–120 V 2.5 kW; 220–240 V 5.5 kW; 380–440 V 7.5 kW |
| Rated Operational Power AC-4 (Pe) | 3-phase: 220–240 V 3.7 kW; 380–440 V 6 kW; 500 V 6 kW; 660–690 V 6 kW. 1-phase: 110–120 V 1.1 kW; 220–240 V 2.2 kW; 380–440 V 3.7 kW |
| Rated Operational Power AC-23A (Pe) | 3-phase: 220–240 V 11 kW; 380–440 V 22 kW; 500 V 30 kW; 660–690 V 22 kW. 1-phase: 110–120 V 2.5 kW; 220–240 V 5.5 kW; 380–440 V 11 kW |
| Maximum Fuse Current | gG 63 A |
| Rated Short-Time Withstand Current (Icw) | 800 A (1 s) |
| Breaking Capacity | 220–240 V: 380 A; 380–440 V: 360 A; 660–690 V: 270 A |
| Power Loss per Pole | 1.3 W |
| Solid Conductor Cable Cross-Section | 1–10 mm2 |
| Stranded Conductor Cable Cross-Section | 2x10 mm2 |
| Flexible Conductor Cross-Section | 1.5–6 mm2 |
| Conductor Cross-Section with Ferrule | 1–6 mm2 |
| Cable section (AWG/MCM) | AWG 8 |
| Conductor Material | Copper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered) |
| Tightening Torque | 2.2 Nm (19.5 lb-in) |
| Recommended Screw Driver | Pozidriv/Phillips PH2; slotted 1.2 x 8 mm (DIN 5264) |
Shipping & assurance
For made-to-order products, the procurement and carrier hand-over time is shared with the quotation.
In rare cases, all or part of an order may be unavailable due to stock or procurement updates. In this case, the customer is informed and the relevant product is cancelled and refunded. A product being open for sale does not guarantee that it is in physical store stock.