Kraus & Naimer C42 A274 is a 3-pole, 63 A step switch with 7 steps and no OFF position. The switch has positions 1-2-3-4-5-6-7, a switching angle of 45° and 11 levels. Front plate size 64 x 64 mm; front plate code F110; size type S1. Rated insulation voltage is 690 V (AC 50/60 Hz) and rated impulse withstand voltage is 6 kV (switch), 4 kV (switch disconnector). AC-21A rated operational current is 63 A over 20–690 V; three-phase AC-3 rated power (380–440 V) is 18.5 kW; AC-23A rated power (380–440 V) is 30 kW. Maximum fuse rating gG 80 A; rated short-time withstand current 1000 A (1 s); power loss per pole 1.7 W. The terminals accept stranded conductors up to 2 x 16 mm²; tightening torque is 3 Nm (26.4 lb-in); operating temperature is -25…+60 °C. It is used to select between several circuit steps; there is no OFF (0) position.
| Size Type | S1 |
|---|---|
| Number of Poles | 3P |
| Cam Switch Position Count | 7 Positions |
| Series | C42 |
| Function Code | A274 |
| Switch Function | Stepped Without Off (1-2-3-4-5-6-7) |
| Switch Positions | 1-2-3-4-5-6-7 |
| Number of Positions | 7 |
| Switching Angle | 45° ° |
| Number of Levels | 11 |
| Front Plate Code | F110 |
| Front Plate Size (A x B) | 64 x 64 mm |
| Rated Current | 63 A |
| Conventional Free Air Thermal Current (Ith) | 63 A |
| Ambient temperature for rated current | 55 °C (24 hours, tepe 60 °C) |
| Conventional Enclosed Thermal Current (Ithe) | 63 A |
| Rated Insulation Voltage (Ui) | 690 V (AC 50/60 Hz) |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV (circuit breaker); 4 kV (switch-disconnector) |
| Overvoltage category | III |
| Pollution Degree | 3 |
| Rated Operational Current AC-15 (Ie) | 220–240 V: 16 A; 380–440 V: 7 A |
| Rated Operational Current AC-20A (Ie) | 690 V: 63 A |
| Rated Operational Current AC-21A (Ie) | 20–690 V: 63 A |
| Rated Operational Current AC-22A (Ie) | 220–500 V: 63 A; 660–690 V: 63 A |
| Rated Operational Power AC-2 (Pe) | 3-phase: 220–240 V 18.5 kW; 380–440 V 30 kW; 500 V 40 kW; 660–690 V 37 kW |
| Rated Operational Power AC-3 (Pe) | 3-phase: 220–240 V 11 kW; 380–440 V 18.5 kW; 500 V 18.5 kW; 660–690 V 18.5 kW. 1-phase: 110–120 V 3 kW; 220–240 V 6 kW; 380–440 V 11 kW |
| Rated Operational Power AC-4 (Pe) | 3-phase: 220–240 V 5.5 kW; 380–440 V 7.5 kW; 500 V 7.5 kW; 660–690 V 7.5 kW. 1-phase: 110–120 V 1.2 kW; 220–240 V 2.4 kW; 380–440 V 4 kW |
| Rated Operational Power AC-23A (Pe) | 3-phase: 220–240 V 15 kW; 380–440 V 30 kW; 500 V 45 kW; 660–690 V 40 kW. 1-phase: 110–120 V 4 kW; 220–240 V 10 kW; 380–440 V 18.5 kW |
| Maximum Fuse Current | gG 80 A |
| Rated Short-Time Withstand Current (Icw) | 1000 A (1 s) |
| Breaking Capacity | 220–240 V: 550 A; 380–440 V: 550 A; 660–690 V: 365 A |
| Power Loss per Pole | 1.7 W |
| Solid Conductor Cable Cross-Section | 1.5–16 mm2 |
| Stranded Conductor Cable Cross-Section | 2x16 mm2 |
| Flexible Conductor Cross-Section | 4–10 mm2 |
| Conductor Cross-Section with Ferrule | 2.5–10 mm2 |
| Cable section (AWG/MCM) | AWG 6 |
| Conductor Material | Copper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered) |
| Tightening Torque | 3 Nm (26.4 lb-in) |
| Recommended Screw Driver | Pozidriv/Phillips PH3; slotted 1.6 x 8 mm (DIN 5264) |