Kraus & Naimer C80 A240 2-Step Cam Switch with OFF, 1-Pole, 115 A, 88 x 88 mm Front Plate

Kraus & Naimer C80 A240 2-Step Cam Switch with OFF, 1-Pole, 115 A, 88 x 88 mm Front Plate

Kraus & Naimer C80 A240 is a 1-pole step cam switch with 2 steps and an OFF (0) position; thermal current 115 A, front plate size 88 x 88 mm. The handle of the C80 A240 turns in 60° steps through the positions 0-1-2, and each position engages a different contact arrangement; number of levels 1, front plate code F075. It is used in multi-position selection and control circuits. For C80 A240, rated insulation voltage Ui is 690 V, AC-21A rated current is 100 A, maximum fuse rating is gG 125 A and rated short-time withstand current Icw is 1300 A (1 s). C80 A240 is connected by screw terminals: flexible conductors of 6–25 mm², conductors with ferrule of 4–25 mm² and stranded conductors of 35 mm² can be connected; tightening torque is 4 Nm.

Size TypeS2
Number of Poles1P
Cam Switch Position Count2 Positions
SeriesC80
Function CodeA240
Switch FunctionStepped With Off (0-1-2)
Switch Positions0-1-2
Number of Positions3
Switching Angle60° °
Number of Levels1
Front Plate CodeF075
Front Plate Size (A x B)88 x 88 mm
Rated Current115 A
Conventional Free Air Thermal Current (Ith)115 A
Ambient temperature for rated current55 °C (24 hours, tepe 60 °C)
Conventional Enclosed Thermal Current (Ithe)115 A
Rated Insulation Voltage (Ui)690 V (AC 50/60 Hz)
Rated Impulse Withstand Voltage (Uimp)6 kV
Overvoltage categoryIII
Pollution Degree3
Rated Operational Current AC-20A (Ie)690 V: 115 A
Rated Operational Current AC-21A (Ie)20–690 V: 100 A
Rated Operational Current AC-22A (Ie)220–500 V: 100 A; 660–690 V: 100 A
Rated Operational Power AC-2 (Pe)3-phase: 220–240 V 30 kW; 380–440 V 45 kW; 500 V 55 kW; 660–690 V 55 kW
Rated Operational Power AC-3 (Pe)3-phase: 220–240 V 15 kW; 380–440 V 30 kW; 500 V 30 kW; 660–690 V 30 kW. 1-phase: 110–120 V 3.7 kW; 220–240 V 7.5 kW; 380–440 V 13 kW
Rated Operational Power AC-4 (Pe)3-phase: 220–240 V 6 kW; 380–440 V 11 kW; 500 V 11 kW; 660–690 V 11 kW. 1-phase: 110–120 V 1.5 kW; 220–240 V 3 kW; 380–440 V 5.5 kW
Rated Operational Power AC-23A (Pe)3-phase: 220–240 V 30 kW; 380–440 V 45 kW; 500 V 55 kW; 660–690 V 45 kW. 1-phase: 110–120 V 5.5 kW; 220–240 V 15 kW; 380–440 V 22 kW
Maximum Fuse CurrentgG 125 A
Rated Short-Time Withstand Current (Icw)1300 A (1 s)
Breaking Capacity220–240 V: 860 A; 380–440 V: 860 A; 660–690 V: 400 A
Power Loss per Pole5.8 W
Solid Conductor Cable Cross-Section2.5–35 mm2
Stranded Conductor Cable Cross-Section35 mm2
Flexible Conductor Cross-Section6–25 mm2
Conductor Cross-Section with Ferrule4–25 mm2
Cable section (AWG/MCM)AWG 3 (flexible); AWG 2 (solid or stranded)
Conductor MaterialCopper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered)
Tightening Torque4 Nm (35 lb-in)
Recommended Screw DriverPozidriv/Phillips PH2; slotted 1.2 x 8 mm (DIN 5264)
Contact TypeRigid bridging link